M-system 20VS5-500 Manual de usuario

20VS5-500
P. 1 / 4EM-4413 Rev.4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
ISOLATION AMPLIFIER
(high speed response, 5kV input isolation) MODEL
20VS5-500
INSTRUCTION MANUAL
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System’s Sales Office or representatives.
■PACKAGE INCLUDES:
Amplifier ....................................................................... (1)
■MODEL NO.
Confirm that the model number described on the product is
exactly what you ordered.
■INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■POWER INPUT RATING & OPERATIONAL RANGE
•PowerSupply
Operational voltage range: 14 – 16V DC
Powerconsumption:Approx.7mADC(noload)
Install the filter for the power supply as indicated below.
■ENVIRONMENT
•Indooruse
•Whenheavydustormetalparticlesarepresentintheair,
install the unit inside proper housing with sufficient ven-
tilation.
•Donotinstalltheunitwhereitissubjectedtocontinuous
vibration.Donotsubjecttheunittophysicalimpact.
•Environmentaltemperature mustbe within-10 to70°C
(14to158°F)withrelativehumiditywithin30to90%RH
in order to ensure adequate life span and operation.
■WIRING
•Do not install cables (power supply, input and output)
close to noise sources (relay drive cable, high frequency
line, etc.).
•Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■INSTALLING THE MODULE
Whenitisinstalledontheprintedwiringboard,landdiam-
eterø1.6andthrough-holeø1.0arerecommended.
■AND ....
•Theunitisdesignedtofunctionassoonaspowerissup-
plied,however,awarmupfor10minutesisrequiredfor
satisfying complete performance described in the data
sheet.
•With voltage output, do not leave the output terminals
shortcircuited for a long time. The unit is designed to en-
dure it without breakdown, however, it may shorten ap-
propriate life duration.
CHECKING
1) Terminal wiring: Check that wiring is correctly connect-
ed according to the connection diagram.
2) Powerinputvoltage:Checkvoltageacrossthepins.
3) Input:Checkthattheinputsignaliswithin0–100%of
the full-scale.
4) Output: Check that the load resistance meets the de-
scribed specifications.
10µF
+
–
COM
POWER
560µH
7
8
+15V
10µF
+
–

20VS5-500
P. 2 / 4EM-4413 Rev.4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
TERMINAL CONNECTIONS
■EXTERNAL DIMENSIONS mm (inch)
■TERMINAL ASSIGNMENTS
PIN ASSIGNMENT
(BOTTOM VIEW)
6
5
4
3
2
1
7
8
9
10
REFERENCE VOLTAGE SOURCE (–)
REFERENCE VOLTAGE SOURCE (+)
COM (–)
NON-INVERTING INPUT
POWER SUPPLY (+)
POWER SUPPLY (–)
OUTPUT (–)
OUTPUT (+)
INVERTING INPUT
FEEDBACK
38 (1.50) 15.2 (.60)
38 (1.50)
25.4 (1.00)
5.08 (.20)
33.02 (1.30)
8
(.31)
0.7 (0.3) dia
+
–
+
–
OUTPUT
2
1
6
7
8
5
3
4
10
9
+
–
POWER
Note. The reference voltage source is common to the COM (–), terminal 4.
REFERENCE
VOLTAGE
SOURCE
COM (–)
INPUT NON-INVERTING INPUT
INVERTING INPUT
FEEDBACK

20VS5-500
P. 3 / 4EM-4413 Rev.4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
APPLICATION EXAMPLES
+
–
+
–
+
–
1
2
Non-inverting circuit G = 1
OUTPUT ±5V DC
–
+
REFERENCE
VOLTAGE SOURCE
■
Non-inverting amplifier circuit: Basic example of G = 1
INPUT ±5V DC
+
–
4
3
5
6
10
9
+
–
POWER SUPPLY 15V DC
7
8
R1
+
–
+
R1R1
–
+
–
Inverting circuit G = -1
OUTPUT ±5V DC
■ Inverting amplifier circuit: Basic example of G = -1 (output inverted to the input)
INPUT ±5V DC +
–
–
+
REFERENCE
VOLTAGE SOURCE
1
2
4
3
5
6
10
9
+
–
POWER SUPPLY 15V DC
7
8
The primary amplifier in this unit is high accurate. Installing external resistors to the inverting input (pin 2) and the feed-
back (pin 1), this unit can be used as a non-inverting or inverting amplifier.
Theseriesresistanceoftheamplier,R1+R2mustbebetween10kΩand200kΩ.
The output is proportional to the input. The
gain is 1.
E.g.±5VDCfor±5VDCinput.
The output is inverted to the input. The gain
is -1.
E.g.+5VDCfor-5VDCinputand-5VDCfor
+5VDCinput.
+
–
+
R2R1
–
+
–
Non-inverting amplifier circuit G = 1 + R1/ R2
OUTPUT VO
■Non-inverting amplifier circuit: Example of G = 1 + R1/ R2
INPUT VIN
+
–
–
+
REFERENCE
VOLTAGE SOURCE
1
2
4
3
5
6
+
–
POWER SUPPLY
15V DC
10
9
7
8
Fora non-inverting amplicationthe output
is following.
VO=(1+R1/R2) × VIN
WhenR1=10kΩ,R2=10kΩ,thentheoutput
is following. The gain is 2.
VO= 2 ×VIN
+
–
+
R2R1
–
+
–
Inverting amplifier circuit G = -R1/ R2
OUTPUT VO
■Inverting amplifier circuit: Example of G = -R1/ R2(output inverted to the input)
INPUT VIN +
–
–
+
REFERENCE
VOLTAGE SOURCE
1
2
4
3
5
6
+
–
10
9
7
8
POWER SUPPLY
15V DC
For an inverting amplication the output is
following.
VO =-(R1/R2) × VIN
WhenR1=20kΩ,R2=10kΩ,thentheoutput
is following. The gain is -2.
VO=-(20kΩ/10kΩ)× VIN = -2 × VIN

20VS5-500
P. 4 / 4EM-4413 Rev.4
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: info@m-system.co.jp
Foranon-invertingamplicationwithex-
ternal adjustments, when the combined
resistanceofthespanadjustmentand9kΩ
is10kΩ,thegainis(1+10kΩ/R2) × VIN.
Withthespanadjustment (2kΩ),theout-
putiscongurable.Thezeroisadjustable
withareferencevoltagesourceof±7.5VDC
andtheattenuationof200Ωand30kΩ.
■ Inverting amplifier's circuit with external adjustment
INPUT VIN +
–
–
+
9kΩ
10kΩ
100kΩ
(ZERO)
2kΩ
(SPAN)
R2
30kΩ
200Ω
+
–
+
–+
–
OUTPUT ±5V DC
1
2
4
3
5
6
+
–
10
9
7
8
REFERENCE
VOLTAGE
SOURCE
POWER SUPPLY
15V DC
Foraninvertingamplicationwithexter-
nal adjustments, when the combined re-
sistanceofthespanadjustmentand9kΩis
10kΩ,thegainis-(10kΩ/R2) ×VIN.With
the span adjustment (2kΩ), the output is
congurable. The zero is adjustable with
areferencevoltagesourceof±7.5VDCand
theattenuationof200Ωand30kΩ.
MAINTENANCE
Regularcalibrationprocedureisexplainedbelow:
■CALIBRATION
Warmuptheunitforatleast10minutes.Apply0%,25%,
50%, 75% and 100% input signal. Check that the output
signal for the respective input signal remains within accu-
racy described in the data sheet.
+
–+
–
Non-inverting amplifier circuit zero/span adjustments (input ±2.5V, output ±5V)
OUTPUT ±5V DC
■ Non-inverting amplifier's circuit with external adjustments: Example of G = 2
+
–
–
+REFERENCE
VOLTAGE
SOURCE
9kΩ
10kΩ
50kΩ
(ZERO)
2kΩ
(SPAN)
INPUT ±2.5V DC
R2
30kΩ
200Ω
+
–
1
2
4
3
5
6
+
–
POWER 15V DC
10
9
7
8
Tabla de contenidos