Lynx ADP Series Manual de usuario

Lynx Pro Audio S.L.
V.21.04
USER MANUAL
ADP series
ADP-26

Manufacturer
CE CERTIFICACTION, EUROPEAN PRODUCT
ADP-26
LYNX Pro Audio S.L.
Calle 1 - Pol. Ind. Picassent
E-46220 Picassent (Valencia)
This user guide is property of Lynx Pro Audio S.L. Any reproduction of this manual, by any means is strictly prohibited.
Copyright 2020. All rights reserved.

ADP Series User Manual
Lynx Pro Audio S.L 3www.lynxproaudio.com
INTRODUCTION
The versatile ADP-26 is part of the ADP Self powered, DSP integrated Series. It has been designed to offer the
utmost sound reinforcement reliability, incorporating the latest acoustical and electronical technology and delivering
incredible, dynamic sound.
The ADP-26 is an extremelly high power, two way full range cabinet providing exceptional performance. Each cabinet
has a DSP integrated for system protection and optimization. This DSP applies linear phase (FIR) and classic crossovers.
Other features include temperature sensor, Ethernet options and many more.
The compact ADP-26 has an unbeatable power to size ratio, there is no need for external amplication racks, is very
light weight and is the ideal solution for portable or xed sound reinforcement. A variety of rigging options make the
ADP-26 easy to set-up in minimal time. To extend the low frequency response, the ADP-18S subwoofer cabinet can
be used.
To facilitate, correct and reliable use of the powered cabinet ADP-26 we have designed this instruction manual. Please
read the manual carefully before proceeding to install the system.
Please observe the technical data carefully and do not ignore the instructions included within this manual.
CONTENTS
• SAFETY PRECAUTIONS 4
• SYSTEM OVERVIEW
ADP-26 5
BACK PANEL 6
• CONNECTORS AND CONNECTIONS 7
CONNECTION EXAMPLE 8
• CONFIGURING THE DIGITAL SIGNAL PROCESSOR
CONFIGURING THE DSP OPTIONS 9
CONFIGURATION PANEL 10
SELECT AND RUN PRESET 10
• ONLINE CONTROL SYSTEM 11
• RAINBOW 3D ACOUSTIC SIMULATION SOFTWARE 12
• HARDWARE AND ACCESSORIES 13
• CERTIFICATIONS AND GUARANTEE 14

ADP Series User Manual
Lynx Pro Audio S.L 4www.lynxproaudio.com
Before starting to use this device, please read this instruction manual carefully.
Keep these instructions in the place where the equipment will be used and with easy access to them.
• Electrical appliance
The exclamation mark within a triangle identies the presence of electricity. Use the system carefully without wet
hands or feet. Avoid installing the speaker in wet or excesivelly humid places. Do not place material that contains
liquid on or near the unit. Avoid dripping or splashing water or any liquid over the unit. Regularly check the condition
of the cables and make sure these are not being walked on or pinched. Connect the speaker to bipolar, earthed
mains. The mains plug must be connected to the appropriate protection (fuse or breaker). Connection to any other
type of mains could result in an electrical shock and violate local electrical codes.
CAUTION: DO NOT CONNECT OR DISCONNECT THE AC POWER CONNECTORS UNDER LOAD.
•Heavy equipment
Apply back protection when using the system. Avoid loading and unloading at heights.
•Electrical shock risk
The diagonal mark within a triangle identies the presence of dangerous voltage.
Do not open or handle the interior of the box. These parts are not to be adjusted by the user. For maintenance and/
or repair please go to an authorized service centre.In order to reduce the risk of electric shock, disconnect from
AC before plug in or unplugging Audio signal cables. Reconnect to AC only if all signal connections are made and
secured. Never manipulate the ground type plug provided.
The AC mains plugs should always remain accessible for operation.
Unplug the loudspeaker during storms or when it’s being used for a long time.
•Hearing damage risk
These systems can reproduce large quantities of sound pressure which can damage hearing. Take precautions if
you are going to be near them for extended amounts of time and do not get too close.
•Hanging / Flying
Do not hang the cabinets from the handles or from any other part other than the designated hanging point. When
ying this system please observe the technical and “Rainbow” software data carefully. Never exceed the maximum
safe working loads or ignore the instructions included within this manual. Use Only ying accessories provided by
Lynx Pro Audio S.L. Rigging must be always carried out by professionals.
•Delicate Material
Please ensure no foreign object or water enters the speaker. Only clean the unit with dry cloths. Do not use solvents.
•Overheating / Fire risk
To reduce the risk of the speaker over heating, avoid direct contact with sunlight. Avoid placing the unit close to heat
inducing objects such as radiators. Do not cover the equipment in use and do not block any ventilation openings.
Do not put naked ame, such as lighted candles, close or on top of the unit.
•Electromagnetic and interferente emissions
Avoid placing objects which through electromagnetic waves can damage the unit, such as mobile phones, lap tops,
magnetic strip cards etc.
This system complies with normatives EN 55103-1 (1)
EN 55103-2 (2)
(1) This device may not cause harmful interferences.
(2) This device may receive interference including interferences that may cause undesired working.
•IMPORTANT NOTE
This Equipment must be used in accordance with these instructions and by trained professional personnel only.
This equipment should not be used in places with extreme tropical climates. Don’t expose this apparatus to extreme
humidity and or temperature values.

ADP Series User Manual
Lynx Pro Audio S.L 5www.lynxproaudio.com
SYSTEM OVERVIEW
• Technical Data:
Components:
•HF 1” titanium diaphragm driver
•LF/MF 2 x 6” neodymium (aluminium demodulating rings)
Frequency range: 65 Hz – 20 KHz (-10dB)
Frequency response: 75 Hz – 18 KHz (± 3dB)
Max SPL / Peak: 124 dB - 127 dB peak
Coverage angle: 90º H x 60º V rotatable horn
Power amplier: 1000W Class D
LF/MF amplier: 1 x 500 W
HF amplier: 1 x 500 W
Processing: 56 bit Lynx DSPB-22 with FIR lters
Cabinet adjustment: Back panel LCD
Control connections: XLR / Ethernet (OCS) optional, USB (DSP programming)
AC power: 230V / 115V selectable. 50/60 Hz 5A
AC connections: 16A Neutrik powerCon TRUE1 with link output
Finish: Polyurea coating high grade resistant paint
Material: 15 mm Premium birch plywood
Dimensions: 530 x 222 x 269 mm (H x W x D)
Weight: 13kg (28 lbs)
•ADP-26
High Output, self-powered (Class D switch mode power supply), two-way cabinet.
Consists of two 6” (1.5” voice coil) neodymium magnet transducers with aluminium demodulating rings and
a 1” compression driver with titanium diaphragm, mounted on a 90ºH x 60ºV rotatable, exponential horn.
DSP (FIR technology) controlled with 1000W amplication, 127dB SPL.
• ADP-26 measurements
274.4
530
222.6

ADP Series User Manual
Lynx Pro Audio S.L 6www.lynxproaudio.com
• ADP-26 back panel
274.4
530
222.6
LCD display
& digital control
Main link Main input
Signal input
Signal link
Ethernet (optional)
USB connection

ADP Series User Manual
Lynx Pro Audio S.L 7www.lynxproaudio.com
CONNECTORS AND CONNECTIONS
XLR AEREAL CONNECTORS
OUTPUTS
1.- EARTH
2.- LIVE (+)
3.- LIVE (-)
INPUTS
1.- EARTH
2.- LIVE (+)
3.- LIVE (-)
XLR SOCKET CONNECTORS
Connect to output
Connect to input
2 Live(+)
3 Live(-)
1 Earth
3 Live(-)
1 Earth
2 Live(+)
SOCKET POWERCON CONNECTORS
L - Line
N - Neutral
- Earth
CAUTION: Do not connect
or disconnect the AC Power
connectors under load.

ADP Series User Manual
Lynx Pro Audio S.L 8www.lynxproaudio.com
Connect to AC output
(max. +2 cabinets)
CAUTION:
Do not connect or disconnect the AC power connectors underload.
Connect to signal output
Connect to AC output
(max. +2 cabinets)
• CONNECTION EXAMPLE: 6 ADP-26 cabinets
CONNECTORS AND CONNECTIONS

ADP Series User Manual
Lynx Pro Audio S.L 9www.lynxproaudio.com
Preset Display Name Additional info
01 FIR FULL RANGE Full range with FIR lters
02 FIR X80Hz 80 Hz high pass with FIR lters
03 FIR X90Hz 90 Hz high pass with FIR lters
04 FIR X100Hz 100 Hz high pass with FIR lters
05 FIR FULL R INV Full range inverted with FIR lters
06 FIR X80Hz INV 80 Hz high pass inverted with FIR lters
07 FIR X90Hz INV 90 Hz high pass inverted with FIR lters
08 FIR X100Hz INV 100 Hz high pass inverted with FIR lters
09 FIR FULL R -6 Full range -6dB with FIR lters
10 FIR FR -6 INV Full range inverted -6dB with FIR lters
11 FULL RANGE Full range
12 X80Hz 80 Hz high pass
13 X90 Hz 90 Hz high pass
14 X100 Hz 100 Hz high pass
15 FULL R INV Full range inverted
16 X80 Hz INV 80 Hz high pass inverted
17 X90 Hz INV 90 Hz high pass inverted
18 X100 Hz INV 100 Hz high pass inverted
19 FULL R -6 Full range -6dB
20 FULL R -6 INV Full range inverted -6dB
From the buttons below the display on the cabinet’s back panel you are able to congure the Basic adjustment
functions of the internal DSP. Depending on the model, you can nd the following congurations:
CONFIGURING THE DIGITAL SIGNAL PROCESSOR
Note:
You must apply the desired conguration in each one cabinet. This is done via the buttons located on the
back panel of the cabinet and requires electrical power to work.
FIR FILTERS
Finite Impulse Response (FIR) lters are used in the signal processing of the ADP-215 cabinet. FIR is a type of
digital lter with linear phase characteristics. This frees system designers from the constraints of phase
anomalies associated with analogue lters or their digital versions (IIR, Innite Impulse Response). When
properly used, FIR ltering can audibly improve a system’s impulse response and reduce crossover interference.

ADP Series User Manual
Lynx Pro Audio S.L 10www.lynxproaudio.com
CONFIGURATION PANEL
On the back panel you will see 3 buttons and an information screen, on which you can read the established
parameters and information such as amplication module temperature, input signal level and name of the
current preset (Fig1).
If changes are not made the display will automatically dim to save energy and avoid unnecessary light in
situations where light is not wanted. To re-activate the light simply press the OK button.
Fig 1
SELECT THE INPUT: DIGITAL OR ANALOG
To change the preset conguration just press the up button (Fig2(1)) and down button (Fig2(2)) until you see the
title and preset number required.
Once found, press OK (Fig2(3)) until the progress bar nishes (Fig3). The display will indicate “Loading DSP”
(Fig4).
2 31 Fig 3 Fig 4
Fig 2
Note:
In case of a power cut, the DSP will save its last congurations when restarted.
Este manual sirve para los siguientes modelos
7
Tabla de contenidos
Otros manuales de Sistema de altavoces de Lynx

Lynx
Lynx yellobrik PDM 1284 D Manual de usuario

Lynx
Lynx ADP-215 Manual de usuario

Lynx
Lynx ionic-100 Manual de instrucciones

Lynx
Lynx GXR-12 Manual de usuario

Lynx
Lynx LX-V12 Manual de usuario

Lynx
Lynx CLS-28 Manual de usuario

Lynx
Lynx LX-F6 Manual de usuario

Lynx
Lynx ionic-100 Manual de instrucciones

Lynx
Lynx LX-318C Manual de usuario

Lynx
Lynx CLS-212 Manual de usuario