Lumantek SKY BAND Guía de inicio rápido

LUMANTEK Co., Ltd http://www.lumantek.com
Head Oce : # 1208, Woolim Lion’s Valley II, 680 Gasan-Dong, Geuncheon-Gu, SEOUL, KOREA (150-803)
VENTUS UPGRADE MANUAL
sKy Band

Trademarks and Copyright
COPYRIGHT © 2006, LUMANTEK Unit 1208, Woolim Lion’s Valley II, 680 Gasan-Dong, Gumcheon Gu,
Seoul Korea (153-830), Tel: +82 2 2027 2400, Fax: +82 2 2027 2409 All rights reserved.
This document contains information that is proprietary to LUMANTEK. No part of this publication may
be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically,
mechanically, by photocopying, or otherwise, without the prior written permission of LUMANTEK. Nationally
and internationally recognized trademarks and trade names are the property of their respective holders and are
hereby acknowledged.
Portions of this software are © 1996-2006 LUMANTEK Ltd. All intellectual property rights in such portions of
the Software and documentation are owned by LUMANTEK and are protected by United States copyright laws,
other applicable copyright laws and international treaty provisions. LUMANTEK and its suppliers retain all
rights not expressly granted.
Disclaimer
The information in this document is furnished for informational purposes only, is subject to change without prior
notice, and should not be construed as a commitment by LUMANTEK.
The information in this document is believed to be accurate and reliable; however LUMANTEK assumes
no responsibility or liability for any errors or inaccuracies that may appear in this document, nor for any
infringements of patents or other rights of third parties resulting from its use. No license is granted under any
patents or patent rights of LUMANTEK.
This document was written by the Technical Support Department of LUMANTEK, Korea. We are committed to
maintaining a high level of quality in all our documentation. Towards this effort, we welcome your comments
and suggestions regarding the content and structure of this document. Please fax or mail your comments and
suggestions to the attention of:
LUMANTEK Attn: Product Support Department Unit 1208, Woolim Lion’s Valley II, 680 Gasan-Dong,
Gumcheon Gu, Seoul Korea (153-830), +82 2 2027 2400, Fax: +82 2 2027 2409
Environmental Issues
Thank you for buying a product which contributes to a reduction in pollution and thereby helps save the
environment.
Our products reduce the need for travel and transport and thereby reduce pollution. Our products have either no
or few consumable parts (chemicals, toner, gas, paper). Our products are low energy consuming products.
Waste handling:
There is need to send material back to LUMANTEK. Please contact your local dealer for information on
recycling the product by sending the main parts of the product for disassembly at local electronic waste stations.
Production of products:
Our factories employ the most efcient environmental methods for reducing waste and pollution by ensuring that
the products are recyclable.

Operator Safety Summary
For your protection, please read these safety instructions completely before operating the equipment and keep this
manual for future reference. The information in this summary is intended for operators. Carefully observe all warnings,
precautions and instructions both on the apparatus and in the operating instructions.
Equipment Markings
The lighting ash symbol within an equilateral triangle is intended to alert the
user to the presence of uninsulated “dangerous voltages” within the product’s
enclosure that may be of sufcient magnitude to constitute a risk of electrical
shock.
The exclamation mark within an equilateral triangle is intended to alert the user
to the presence of important operating and maintenance (servicing) instructions
within literature accompanying the equipment.
Warnings
Water and Moisture - Do not operate the equipment under or near water - for example near a bathtub, kitchen sink, or
laundry tub, in a wet basement, near a swimming poor or in areas with high humidity.
Cleaning - Unplug the apparatus from the wall outlet before cleaning or polishing. Do not use liquid cleaners or aerosol
cleaners. Use a lint-free cloth lightly moistened with water for cleaning the exterior of the apparatus.
Ventilation - Do not block any of the ventilation openings of the apparatus. Install in accordance with the installation
instructions. Never cover the slots and openings with a cloth or other material. Never install the apparatus near heat
sources such as radiator, heat registers, stoves, or other apparatus (including ampliers) that produce heat.
Grounding or Polarization - Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized
plug has two blades with one wider than the other. A grounding type plus has two blades and a third grounding prong.
The wide blade or third prong is provided for your safety. If the provided plug does not t into your outlet, consult an
electrician.
Power-Cord Protection - Route the power cord so as to avoid it being walked on or pinched by items placed upon or
against it, paying particular attention to the plugs, receptacles, at the point where the cord exits form the apparatus.
Attachments - Only use attachments as recommended by the manufacture.
Accessories - Use only with a cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Lighting - Unplug this apparatus during lightning storms or when unused for long periods of time.
ISDN cables - CAUTION - to reduce the risk of re, use only No. 26 AWG or larger
telecommunication line cord.
Servicing - Do not attempt to service the apparatus yourself as opening or removing covers
may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all
servicing to qualied service personnel.
Damaged Equipment - Unplug the apparatus from the outlet and refer servicing to qualied
personnel under the following conditions:
When the power cord or plug is damaged or frayed
If liquid has been spilled or objects have fallen into the apparatus
If the apparatus has been exposed to rain or moisture
If the apparatus has been subjected to excessive shock by being dropped, or the
cabinet has been damaged
If the apparatus fails to operate in accordance with the operating instruction

VENTUS - USB TYPE OF DTV/MOBILE TV SIGNAL GENERATOR // 4
User Manual // 1. Introduction
1. OVERVIEW
1. Sky Band’s Frequency Range - S Band is (2.633 ~ 2.660GHz),
L Band is (1.452 ~ 1.492GHz)
Sky Band’s Power Range is from 0 to -100 dBm and Error range is ±1 dBm.
* The power range of 50 ~ 870Mhz is 10 ~ -110 dBm.
< Installation Tips >
To use the optional Sky Band Attn-Plus must be at least the version 1.2.1.0.
Also, T-pump version must be at least the version 3.0.0
<Check List>
1. VENTUS, Atten-plus manufactured in set.
2. Later, if you purchased the Sky Band, you need to check Attn-Plus version.
Therefore, the existing Attn-Plus is to update the Firmware.
3. To find the Version, go to Help menu on T-pump program and check Atten + ID
value.
Attn-Plus’s Firmware Updates are in the same order as below.
1. Please connect [Ventus] to your PC and turn on the Power.
2. If the T-Pump is running then shuts down the program.
3. After you opened the compressed file, double click to run
VentusAttenUpdateFirmware.exe.
4. When the update is complete, close the window and run the T-pump program.
Go to Help > About - Determine Atten Plus version is at least the version
1.2.1.1.
5. You have completed the Updates.

VENTUS - USB TYPE OF DTV/MOBILE TV SIGNAL GENERATOR // 5
User Manual // 1. Introduction
1-2. Connetors Features
> Upgrade for Atten-Plus Firmware
Update.
> VHF/UHF Attenpuls connector,
if necessary.
> Sky band Firmware Update,
if necessary.
> Sky band Operator Connector

VENTUS - USB TYPE OF DTV/MOBILE TV SIGNAL GENERATOR // 6
User Manual // 1. Introduction
2. HOW TO INSTALL SKY BAND
After Updating the Attn-Plus’s Firmware, install the sky band as below.
1. Please unscrew four screws on Ventus.

VENTUS - USB TYPE OF DTV/MOBILE TV SIGNAL GENERATOR // 7
User Manual // 2. Prdouct Description
2. Please dismantle the data cable connection from Ventus.
a.
b.

VENTUS - USB TYPE OF DTV/MOBILE TV SIGNAL GENERATOR // 8
User Manual // 2. Prdouct Description
3. Please attach Sky Band as shown below.
a.
b.

VENTUS - USB TYPE OF DTV/MOBILE TV SIGNAL GENERATOR // 9
User Manual // 3. System Installation
c.
d.

VENTUS - USB TYPE OF DTV/MOBILE TV SIGNAL GENERATOR // 10
User Manual // 3. System Installation
e.
Tabla de contenidos
Otros manuales de Instrumento de medición de Lumantek
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario














