Lucent Technologies Lineage 2000 ECS-6U Manual de usuario

Product Manual
J85501E-1
Select Code 167-790-045
Comcode 106704067
Issue 4
August 1998
Lucent Technologies
Lineage®2000
ECS-6U Controller
Notice:
Every effort was made to ensure that the information in this
document was complete and accurate at the time of printing.
However, information is subject to change.
©1998 Lucent Technologies
All Rights Reserved
Printed in U.S.A.

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
Issue 4 August 1998 Table of Contents - 1
Table of Contents
1 Introduction
General Information 1 - 1
Customer Training 1 - 4
Customer Service 1 - 4
Technical Support 1 - 4
Product Repair and Return 1 - 4
Warranty Service 1 - 4
2 Product Description
Overview 2 - 1
Basic Controller 2 - 5
Operating Voltage 2 - 5
Batteryless Operation 2 - 5
Rectifier Sense Leads 2 - 5
Office Alarm Contacts and Alarm Battery Supply 2 - 6
Battery on Discharge Alarm 2 - 7
Selective High Voltage Shutdown 2 - 7
Automatic Rectifier Restart 2 - 9
Rectifier Fail Alarm 2 - 10
AC Fail Alarm 2 - 11
Major and Minor Fuse Alarms 2 - 11
Open Battery String Detection and Alarm 2 - 11
Front Panel Status Indicators 2 - 12
Front Panel Meter 2 - 12
Ammeter Scale 2 - 13
Front Panel Test Jacks 2 - 13
Rectifier Sequence Control Interface 2 - 13
Float and Equalize Control 2 - 14
Fuse Alarm Board (FAB) 2 - 15
Power and Sense Voltage Fusing 2 - 15
Major and Minor Fuse Alarms 2 - 16
Controller Options 2 - 16
Microprocessor Board 2 - 16
Datalogger Board 2 - 16
Rectifier Adapter Board 2 - 16
Order Wire Board 2 - 17

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
2 - Table of Contents Issue 4 August 1998
Circuit Options 2 - 17
Boost Charge Circuit 2 - 17
Shunt Isolator Circuit 2 - 18
Mixed Types of Rectifiers in One Plant 2 - 18
Controller Specifications 2 - 18
3 Ordering Information
Controller 3 - 1
Kits 3 - 2
Spare Parts 3 - 3
Documentation 3 - 4
4 Installation and Setup
Introduction 4 - 1
Tools Required 4 - 1
Shipped-Loose Unit Installation 4 - 1
Preparation 4 - 1
Default Factory Settings 4 - 2
Frame Mounting 4 - 3
Hardware Setup 4 - 5
Voltage Selection 4 - 5
Equalize Enable/Disable 4 - 6
Automatic Restart Enable/Disable 4 - 7
Ammeter Scale 4 - 7
Battery on Discharge Threshold 4 - 8
High Voltage Shutdown Thresholds 4 - 8
Rectifier Port Selection 4 - 9
Optional Rectifier Adapter Board (RAB) 4 - 16
Optional 248A Order Wire Board 4 - 18
Optional Boost Charge Panel (FT Series G Only) 4 - 20
Shunt Isolator Circuit 4 - 22
Wiring 4 - 25
Basic Controller 4 - 25
Microprocessor and Datalogger Boards 4 - 29
Circuit Pack Installation 4 - 29
External Wiring 4 - 29
5 Acceptance Testing
Test Procedures 5 - 1
Meter Calibration 5 - 2
Battery on Discharge Alarm Test 5 - 2
Float and Equalize Control Test 5 - 3
High Voltage Shutdown and Restart Test 5 - 4

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
Issue 4 August 1998 Table of Contents - 3
Fuse Alarm Test 5 - 6
Remote On/Off (TR Signal) Test 5 - 8
Bulk Ringer Alarm Test 5 - 8
6 Operation
Front Panel Switches and Indicators 6 - 1
7 Troubleshooting
Flowcharts 7 - 1
8 Product Warranty
Appendix
ACompatible Lucent
Technologies Rectifiers

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
Issue 4 August 1998 List of Figures - 1
List of Figures
Figure 1-1: ECS-6U Controller 1 - 2
Figure 1-2: Typical ECS Controller Application 1 - 3
Figure 2-1: Front View of ECS-6U Controller
(Door Shown in Full Open Position) 2 - 2
Figure 2-2: ECS-6U Controller Block Diagram 2 - 3
Figure 2-3: Detail of 113A2 Control Unit Display
Panel 2 - 4
Figure 4-1: 26-inch Frame with Flush Mounting 4 - 3
Figure 4-2: 26-inch Frame with 5-inch Non-Flush
Mounting (List BA) 4 - 3
Figure 4-3: 23-inch Frame with 9-inch Flush Front
Mounting (List BA) 4 - 4
Figure 4-4: ECS-6U Controller Backplane (Upper) 4 - 4
Figure 4-5: CP1 Jumper and Switch Locations 4 - 11
Figure 4-6: CP1 DIP Switch Settings 4 - 12
Figure 4-7: ECS-6U Controller Backplane (Lower) 4 - 12
Figure 4-8: Rectifier Interface Board (RIB) Layout
and Switch Locations 4 - 13
Figure 4-9: RIB DIP Switch Settings 4 - 14
Figure 4-10: Control Cable for Non-Lucent
Technologies Rectifier Connection 4 - 14
Figure 4-11: Rectifier Adapter Board (RAB) Layout
and Switch Locations 4 - 15
Figure 4-12: RAB DIP Switch Settings 4 - 16
Figure 4-13: 248A Order Wire Board 4 - 18

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
2 - List of Figures Issue 4 August 1998
Figure 4-14: Boost Charge Panel (Front and
Rear Views) 4 - 19
Figure 4-15: Shunt Isolator Circuit 4 - 21
Figure 4-16: Typical Alarm Application Schematic 4 - 30
Figure 4-17: Typical Alarm Wiring Examples 4 - 31
Figure 5-1: Fuse Alarm Test 5 - 7
Figure 6-1: Front Panel Location of Controls
and Displays 6 - 3
Figure 7-1: Office Alarms Received 7 - 2
Figure 7-2.1: 113A2 Control Unit Has Lost Power 7 - 3
Figure 7-2.2: 113A2 Control Unit Has Lost Power
(continued) 7 - 4
Figure 7-3.1: Verify Controller Alarms 7 - 5
Figure 7-3.2: Verify Controller Alarms (continued) 7 - 6
Figure 7-3.3: Verify Controller Alarms (continued) 7 - 7
Figure 7-3.4: Verify Controller Alarms (continued) 7 - 8
Figure 7-4: Display Is Not Lit 7 - 9
Figure 7-5: Meter Out of Calibration 7 - 10

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
Issue 4 August 1998 List of Tables - 1
List of Tables
Table 2-A: ECS-6U Controller Electrical Specifications 2 - 18
Table 2-B: Battery Plant Alarm Voltage Ranges 2 - 20
Table 2-C: ECS-6U Controller Physical Specifications 2 - 20
Table 3-A: ECS-6U Controller Ordering Information 3 - 1
Table 3-B: Kits 3 - 2
Table 3-C: Recommended Spare Parts 3 - 3
Table 4-A: Default Factory Settings for Circuit Boards 4 - 2
Table 4-B: Wire Descriptions and Functions 4 - 6
Table 4-C: SW109 DIP Switch Settings 4 - 8
Table 4-D: Available Rectifier Interface Cables 4 - 10
Table 4-E: Non-Lucent Technologies
Rectifier Control Signals 4 - 17
Table 4-F: External Connections Required to
Establish a Communication Link over the
FT-Series G Embedded Telemetry System 4 - 19
Table 4-G: Shunt Isolator Circuit Pack Shunt Voltage
Programming 4 - 23
Table 4-H: AKC1B Shunt Isolator Circuit Pack
Shunt Current Programming 4 - 24
Table 4-I: Terminal Block Pin Assignments for
113A2 Control Unit 4 - 25
Table 6-A: Front Panel Switches and Indicators 6 - 1

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
2 - List of Tables Issue 4 August 1998

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
Issue 4 August 1998 Introduction 1 - 1
1 Introduction
General
Information This product manual, Select Code 167-790-045, describes the
J85501E-1 ECS-6U Universal Rectifier Controller. The basic
ECS-6U controller monitors and controls any combination ofup
to six Lucent Technologies switchmode (SR) or Lineage®2000
ferroresonant rectifiers and provides a single interface point for
power alarm and status reporting. When ordered with the
optional microprocessor and datalogger features, it adds the
latest technology in the product line to the battery plant.
When used with the optional Rectifier Adapter Board (RAB),
the ECS-6U controller allows rectifiers of various technologies,
vintages, and vendors to be tied together in the same battery
plant and can be used for retrofit applications in older Lucent
Technologies battery plants such as the 150 series, the 326
series, or the 111A. It can also be used to replace older
technology controllers in other vendors' battery plants.
Upgrading can be accomplished by placing the controller in a
supplemental bay or in the same bay as the original equipment.
Appendix A is a list of the various Lucent Technologies
rectifiers, both J- and KS-coded, that have the automatic restart
feature and are compatible with the ECS-6U.
The ECS-6U demonstrates Lucent Technologies' continuing
dedication to providing state-of-the-art energy systems
management products for all battery plants, both old and new.
The Lineage®2000 Battery Plant product line is designed to
provide battery-backed common system office voltages of
+24Vdc, -24Vdc, or -48Vdc in telecommunications
applications.
The ECS-6U controller is shown in Figure 1-1. A typical ECS
controller application is shown in Figure 1-2.

Lucent Technologies Lineage®2000 ECS-6U Controller J85501E-1
1 - 2 Introduction Issue 4 August 1998
Figure 1-1: ECS-6U Controller
Lucent