Lowell MSM2 Manual de usuario

Model: MSM2
Momentary Switch Module
©2010 Lowell Manufacturin Company, 100 Inte ram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—
636.257.6606. Lowell makes every effort to provide accurate information while reservin the ri ht to chan e
specifications and/or improve manufacturin methods without notification. (lowellmf .com)
Spec. No. 1141
(rev. 04.22.11)
pg. 1 of 2
Model No. Description Power Requirements (drawn from host) Remote Switch Maximum
S 2 omentary Switch odule 24VDC, 30mA 6 with RPCs (100mA max) or 12 with SCS-4 (200mA max)
Description:
The momentary switch module ( S 2) allows equipment that’s con-
nected to a remote power control (RPC-series) or 4-step sequencer
(SCS-4) to be switched from multiple locations. The S 2 is placed
between the RPC (or SCS-4) and multiple momentary switches. It
converts the normally open momentary contact closures to latching,
maintained closures. This allows multiple switches in a variety of lo-
cations to activate connected equipment. When the S 2 is con-
nected, a momentary closure on any remote switch causes the S 2
to change the state from open to closed or from closed to open, turn-
ing the RPC (or SCS-4) on or off. The S 2 features dual terminal
strips to connect (2) SPST momentary-style switches. Additional
switches can be added in parallel (6 total for use with RPC-series or
12 total for use with the SCS-4). LED indicators display system sta-
tus (on or off). The S 2 does not require an external power source
as it draws power from the host unit (RPC-series or SCS-4).
Features:
• Compact unit (5"L x 3.279"W x 1.687"H)
• Steel chassis with black powder epoxy finish includes mounting
holes and connection diagram.
• ount to a blank rack panel or rack shelf that’s pre-punched for
electronic devices (Lowell odel No’s. USE-210 or USE-310, order
separately)
• ade in the USA
A & E Specifications:
The device for converting normally open momentary contact closures
to latching maintained closures shall be Lowell momentary switch mod-
ule odel No. S 2. It shall allow for multiple momentary style
switches to be used to activate equipment that is connected to Lowell
RPC-series remote power controls or Lowell SCS-4 sequence con-
troller. The S 2 device shall include 1 terminal strip for connection
to remote power control odel No.______(RPC-series) or sequence
controller odel No. SCS4. It shall also include 2 terminal strips to
connect up to 4 momentary switches odel No.______(RPSB-series)
when connected to a remote control (RPC-series) host; or up to 12
momentary switches odel No._______(RPSB-series) when con-
nected to sequence controller odel No. SCS-4 as a host.
Compatible Remote Switches: (order separately)
Momentary closure switch — three conductors:
RPSB- P ........Black Decora wall plate switch (rocker switch, 1 LED)
RPSW- P .......White Decora wall plate switch (rocker switch, 1 LED)
RPSB- KP......Black Decora wall plate switch (key switch, 1 LED)
RPSW- KP.....White Decora wall plate switch (key switch, 1 LED)
RPSB- R........IU rackmount switch (rocker switch, 1 LED)
RPSB- KR......IU rackmount switch (key switch, 1 LED)
Momentary closure switch — four conductors:
RPSB2- P ......Black Decora wall plate switch (rocker switch, 2 LEDs)
RPSW2- P .....White Decora wall plate switch (rocker switch, 2 LEDs)
RPSB2- KP....Black Decora wall plate switch (key switch, 2 LEDs)
RPSW2- KP...White Decora wall plate switch (key switch, 2 LEDs)
RPSB2- R......IU rackmount switch (rocker switch, 2 LEDs)
RPSB2- KR....IU rackmount switch (key switch, 2 LEDs)
Compatible Host Devices: (order separately)
RPC-1....................................Remote power control (15A, 1 duplex, cord)
RPC-1-20A-CD......................Remote power control (20A, 1 duplex, cord)
RPC-1-20A- C .....................Remote power control (20A, 1 duplex, hardwired)
RPC-1-30A- C .....................Remote power control (30A, 1 twistlock, hardwired)
RPC-1-IG- C........................Remote power control (20A, 1 IG duplex, hardwired)
RPC-1-TVSS-CD...................Remote power control (20A, 1 duplex, cord)
RPC-1-TVSS- C ..................Remote power control (20A, 1 duplex, hardwired)
RPC-4-CD .............................2U rackmount panel with remote control (15A, 4 duplex, cord)
RPC-4- C.............................2U rackmount panel with remote control (15A, 4 duplex, hardwired)
ACS-1510-RPC .....................Power strip with remote control (15A, 5 duplex, cord)
ACS-2010-RPC-HW..............Power strip with remote control (20A, 5 duplex, hardwired)
ACS-2010-IG-RPC-HW.........Power strip with remote control (20A, 5 IG duplex, hardwired)
ACS-2018-5C-RPC-HW ........Power strip with remote control (20A, 9 duplex, 5 circuit, hardwired)
ACS-2018-IG-5C-RPC-HW ...Power strip with remote control (20A, 9 IG duplex, 5 circuit, hardwired)
SCS-4....................................Sequence controller
1.55"
5.00"
4.50"
3.10"
(3) plug-in Phoenix-
style connectors
provided with unit
Terminals will accept
up to 14-ga. wire,
stranded or solid
(2) 7/32"
mounting
holes

Spec. No. 1141
(rev. 04.22.11)
pg. 2 of 2
©2010 Lowell Manufacturin Company, 100 Inte ram Dr., Pacific MO 63069. Phone–800.325.9660 Fax—
636.257.6606. Lowell makes every effort to provide accurate information while reservin the ri ht to chan e
specifications and/or improve manufacturin methods without notification. (lowellmf .com)
Model: MSM2
Momentary Switch Module
Typical application with RPC unit:
Toggle (flip-flop) between two RPC units:
Additional RPC units may be added.
Connect Com and Sw terminals ONLY.
3 conductors*
Connection to RPC-1.
Connections are identi-
cal for all RPC-series .
4 conductors*
3 conductors*
Additional switches
may be added
(max. 6 total).
Note: Two remote switch
terminal blocks are provided
for convenience. Terminals are
parallel connected internally.
Three conductors connect to omentary Switch odels:
RPSB- P
RPSW- P
RPSB- KP
RPSW- KP
RPSB- R
RPSB- KR
Four conductors connect to omentary Switch odels:
RPSB2- P
RPSW2- P
RPSB2- KP
RPSW2- KP
RPSB2- R
RPSB2- KR
SPST normally open momentary
switches (unlimited quantity).
Note: Two remote switch terminal blocks
are provided for convenience. Terminals
are parallel connected internally.
*Note: 22-ga. wire maximum distance 6,000 ft.
18-ga. wire maximum distance 15,000 ft.
Otros manuales de Unidad de control de Lowell
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario