LinkBone 8x8 Matrix Manual de usuario

LinkBone Switch
Type: 8x8 Matrix/Dual 8x8 Matrix
User manual
Version 0.9
Copyright © 2014 LinkBone. All rights reserved.

2
LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
Table of ontents
1. Safety instructions .......................................................................................................................... 3
2. Inspection of the instrument .......................................................................................................... 5
3. Device description ........................................................................................................................... 6
3.1 Front panel .............................................................................................................................. 7
3.2 Rear panel ............................................................................................................................... 8
3.3 Instrument setup .................................................................................................................... 9
3.4 19'' Rack system mounting procedure .................................................................................. 10
4. System Display .............................................................................................................................. 11
4.1 Main screen ........................................................................................................................... 11
4.2 Screen settings ...................................................................................................................... 13
4.3 Infrared Remote Control settings ......................................................................................... 14
4.4 Ethernet settings ................................................................................................................... 16
4.5 RS-232 settings ...................................................................................................................... 18
5. Ethernet remote control port ....................................................................................................... 19
5.1 HTTP server ........................................................................................................................... 19
5.2 Telnet Server ......................................................................................................................... 21
6. Access through RS-232 interface .................................................................................................. 22
7. Text commands accepted by LinkBone Switch 8x8 Matrix/Dual 8x8 Matrix type ....................... 23
8. Device cleaning ............................................................................................................................. 24
9. Product recycling .......................................................................................................................... 24
10. Specifications ............................................................................................................................ 25
11. Appendix A - Electromagnetic Compatibility ............................................................................ 26
12. Appendix B - Licenses ................................................................................................................ 27

LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
3
1. Safety instructions
The user should get familiar with safety requirements and operating instructions before turning
on the device for the first time to prevent personal injury or damage of equipment. The
manufacturer does not take responsibility for any instrument damages or personal injuries caused
by not restricting the device operation instructions and specifications.
The LinkBone Switch must be only used with the power adapter provided by the manufacturer. The
device should be operated at temperature range from 0 to 40 °C and low humidity environment.
Ensure adequate air circulation to prevent overheating of the device. During operation the device all
its components must be always dry and used in an atmosphere free of conductive pollution. The
operating atmosphere should not contain explosive and corrosive gases. In case of suspected device
failure or any other hazardous situation the user should immediately stop the operation of the
device. Keep all elements of the system away from children.
The device should not be exposed to direct sunlight. In case of spilling liquid on the equipment,
immediately disconnect the power supply and discontinue its use.
During installation please note that device housing and all connectors are connected to the negative
rail of the power supply adapter (marked as "-" or ground on the 12VDC connector). Do not short the
device ground to elements with different electric potential (e.g by connecting device housing or
external cables). Touching device ground and elements with the different electric potential can
result in electric shock.
In order to connect external equipment to LinkBone Switch the user should always check the
electrical and mechanical compatibility of the devices. The specified voltage and current values for
the connectors cannot be exceeded. In case of incompatibility of electrical or mechanical properties
devices should not be connected.
When connecting external equipment to ports with labels from A to P please use proper protection
against signal reflections, electrostatic discharge and other intended or unintended(e.g. by device
failure) short circuits with other port lines or ground. Make sure that cables being connected to the
device are previously discharged to prevent damage of the equipment from ESD. It is not
recommended to use LinkBone Switch with sensible equipment which can be damaged by
unexpected electric signals or short circuits. The manufacturer is not liable for any equipment
damage resulting from not using suitable protection circuits or improper use of the LinkBone Switch.
To reduce probability of device failure because of external noise sources shielded cables should be
used. Please use proper overvoltage protection to prevent damage of the equipment (e.g by
lightning strike). se only fuse types specified for given device.
Do not operate the unit with the cover or any part of casing removed. When the power supply is
connected to LinkBone Switch do not touch elements with high voltage.
To change the batteries in IR remote control please remove the bottom battery cover. Replace the
batteries according to the drawing under the battery cover. Please pay attention to the battery

4
LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
polarities and type. Insert the battery cover. The manufacturer is not liable for damage to the
remote control because of badly inserted batteries.
The device LinkBone Switch fulfills the requirements of European nion directives for conducted and
radiated emissions, as specified in the appendix of this manual. Connecting external high amplitude
or high frequency signal sources to LinkBone Switch ports may increase the emissions level of the
device to the value which does not comply with E directives. Therefore, the user is obligated to
check if conducted and radiated emission levels were not exceeded after connecting external signal
sources and receivers to the LinkBone Switch ports. If emission requirements are not met the user
should tune the signal sources to reach an acceptable level of the EM emission.
If guarantee seals are broken or removed the manufacturer is not responsible for secure and proper
operation of the device. All repair or servicing activities should be performed only by authorized
service centre. Care should be taken to avoid mechanical damage of the unit during transport. Do
not faulty or damaged device.
In order to ensure safe and fault free operation of the device it is recommended to do the inspection
of the unit once a year by an authorized service center.
The manufacturer reserves the right to modify or completely change the operating instructions and
specification of the device at any time. The latest version of documentation can be found at
www.LinkBone.com.
Manufacturer:
Z H Kamserwis
PL98-400 Wieruszow
ul. Kasztanowa 4
tel. +48 601 743 537

LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
5
2. Inspection of the instrument
After receiving the unit please inspect if the shipping container is not damaged and the check
the completeness of the delivery. In case of mechanical or electrical damage please contact the sales
representative. The responsibility for device damages during the delivery is held by sender or carrier
side. The manufacturer is not liable for defects caused during transport. In case of damage of
shipped goods please keep the complete shipping container and filling.
Before the first run of the device please check that none of the instrument elements are damaged or
defective. Pay special attention inspecting the power adapter supplied with the unit to avoid electric
shock. In case of finding defect please contact sales representative.
Packing list:
-LinkBone Switch, 8x8 Matrix type
-AC wall adapter 12V/1000mA
-Infrared remote control
-Two mounting brackets for 19" rack installation with screws
- Self adhesive rubber feet for placing the device on a flat surfaces
-ser manual

6
LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
3. Device description
LinkBone 8x8 Matrix Switch allows switching digital and analog signals between two sets of eight
bidirectional ports. One set of ports with labels A to H represents matrix column. Second set of ports
with labels I to P represents matrix row. The device internal switching matrix can connect any
column port with any row port. Gold cladding on internal switching contacts ensures very low
resistance and failure rate. In order to maximize the contact life time all switching contacts are cut
off from external atmosphere to prevent from corrosion and oxidation. The state of internal
switches does not change after interruption or disconnection of power supply which allows limiting
power consumption in standby mode to minimum. The architecture of LinkBone instruments
provides high reliability of switching for wide range of signal voltage levels and current values.
The block diagram illustrating the connection of input/output ports is shown in figure 1. Ports
with symbols from A to H represent matrix column and ports from I to P matrix row. The switching
matrix includes 64 relay switches allowing connecting any row port with any column port. Each
switch state is set by user configuration independently. All lines can route electrical signals
bidirectionally between ports. Meaning that each port can operate as an input or output. To prevent the
accumulation of electrostatic charge that can damage connected devices, each port is connected to
ground via a 5.1 MΩ resistor. For detailed port parameters and characteristics please refer to
chapter 10 (Specifications).
Due to internal construction of signal ports, there are two LinkBone Switch types:
-8x8 Matrix: each port contains only one line for routing electrical signals
-Dual 8x8 Matrix: each port has two symmetrical lines for routing electrical signals with
numbers 1 and 2 (e.g. for stereo audio or differential signals)
Figure 1: LinkBone 8x8 Matrix Switch internal port connection diagram.

LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
7
The device operates in two port switching modes:
-single – only one connection it allowed between two selected ports from matrix row and
column. This mode is dedicated for applications where only two ports can be connected
simultaneously. To avoid short circuit of multiple ports during the switching procedure first
all ports are being disconnected and then final connection is established.
-multi – multiple ports can be connected via matrix switch network.
NOTE: because several ports can be shorted together during switch operation, proper
protection circuits/techniques are needed to avoid damage of connected equipment.
The port connection configuration can be done via touch screen located on the front panel or
remotely via Ethernet, RS-232 or infrared remote control.
The access via Ethernet interface is possible by following services::
-HTTP server with user configuration page described in chapter 5.1 (HTTP server)
-Telnet server accepting text commands described in chapter 7 (Text commands accepted by
LinkBone Switch 8x8 Matrix/D al 8x8 Matrix type)
The switch control via RS-232 interface is done by using text commands with syntax similar to the
Telnet server commands described in chapter 7 (Text commands accepted by LinkBone Switch 8x8
Matrix/D al 8x8 Matrix type).
Additionally the switch status can be configured by included RC5 infrared remote control.
3.1 Front panel
Figure 2 shows the front panel of the LinkBone Switch containing the following elements:
1) power switch (position I means that power is on and O indicates that power is off)
2) status indicator, the blue color indicates that the device is ready for operation
3) infrared Remote Control (RC) sensor with RC5 decoder
4) reset button with the following functions:
•single button press disconnects all ports
•holding down button for 5 seconds starts touch screen calibration procedure
5) RS-232 port described in chapter 6 (Access thro gh RS-232 interface)
6) Ethernet port described in chapter 5 (Ethernet remote control port)
7) System Display with touch screen described in chapter 4 (System Display)

8
LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
Figure 2: Front panel of the LinkBone Switch.
3.2 Rear panel
Figure 3 shows the rear panel of the LinkBone Switch containing the following elements:
8) A to P bidirectional signal ports. The specification of the ports can be found in chapter 10
(Specifications).
a. The BNC port version has the following pin connections:
Center nut – port signal line
Shield – ground connection
b. The XLR port version has the following pin connections(pin numbers are included on
the XLR connector):
1 - ground connection
2 – positive signal line
3 – negative signal line
9) fuse socket, for fuse replacement type please refer to chapter 10 (Specifications).
10) 12V DC input power connector, refer to chapter 10 (Specifications) for more information.
Figure 3: Rear panel of the LinkBone Switch.

LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
9
3.3 Instrument setup
Before powering the LinkBone Switch please place it on a flat, stable and dry surface. Stick the
four self adhesive rubber feet on the bottom surface of the device housing. Ensure that there is no
access to the unit by children. Insert the power adapter DC plug into 12VDC socket on the rear panel
of the device. Set the power switch on front panel into O position. Please make sure that used AC
power outlet fulfills the power requirements described in chapter 10 (Specifications). Plug the power
adapter into your AC power outlet. Figure 4 shows the power connection diagram.
.
Figure 4: Connection of the LinkBone Switch to the power outlet.
To turn on the unit set the power switch position on position. The status indicator will light up
red. After a few seconds the light color should change to blue indicating the device readiness for
operation. The system display will show the main screen described in chapter 4 (System Display). If
the status indicator will not light up after power on please check the fuse on the rear panel. In case
of error message printed on the System Screen please contact your local sells representative in order
to analyze the problem.

10
LinkBone Switch ser manual
, 8x8 Matrix
/Dual
8x8 Matrix type
3.4 19'' Rack system mounting procedure
The LinkBone Switch can be mounted in a standard a 19" rack frame using included brackets.
The instalation handles are fastened with four screws on both sides of the housing as shown in
figure 5. Please make sure that all screws are tightened at there is no loose connection between the
unit housing and the handle. Four oval shaped holes on the mounting handles are used for unit
installation into rack rails. The equipment installation procedure in 19” rack frames is dependent on
the used frame system and should be described in rack installation instructions. Installation of the
LinkBone Switch in 19" rack should be performed only by adequately qualified personnel.
Figure 5: Installation of LinkBone Switch mounting handles for 19” rack systems.
Tabla de contenidos