Lexor ULTIMA Manual de usuario

Pioneering “Smart” Pedi-Spas
PEDICURE SPA USER MANUAL
ULTIMA®
Before Operating the unit, please read this manual thoroughly and retain it for future reference.
RECEIVING AND INSPECTION:
TRADEMARK DISCLAIMER
Vigor, Stellar, Ultima and Princess Seat are the registered trademarks of Lexor. Reproduction or reuse of part or all of trademarks are
expressly prohibited without written permission from Lexor. Due to limitation of the printing process, product colors shown might look
different from actual colors. Lexor will not be responsible for any misprint of this advertisement. Lexor’s footspa specification and prices
may change without prior notice. Pedicure Spas are intended for professional used only, always follow your State Board’s sanitation and
disinfectant guideline.
PLEASE TAKE NOTE! Thoroughly inspect each shipment immediately upon arrival. It is
important that you notify the driver and insist on a notation of the damage. Make this
notation directly on the freight company’s waybill or bill of lading. Failure to note damage on
the waybill or bill of lading may impede and/or prevent any claims that you may have
against the freight carrier.
If missing parts or damage is found. Please notify the carrier at once and request an
inspection. DO NOT DISCARD THE SHIPPING BOX. If you give the carrier a clear receipt
for goods that have been damaged in transit, you do so at your own risk and expense.

2
Table of Contents
SAFETY PRECAUTIONS:................................................................................................. 3
Parts
Identifying Parts for Ultima® Model................................................................................... 4
SPA to SPA RECOMMENDED CLEARANCE:.................................................................. 5
Wall Clearance:................................................................................................................. 5
MANICURE TRAY/ ARMREST / BACK REST INSTALLATION........................................ 6
Up/Down Swinging Armrest:........................................................................................................6
Plumbing Connections:...................................................................................................... 7
Power Drain (optional):................................................................................................................7
Gravity Drain (No Drain Pump):...................................................................................................8
Plumbing Flow Pattern for Power Drain:......................................................................................8
Plumbing Flow Pattern for Gravity Drain:.....................................................................................9
HOT AND COLD WATER SUPPLY LINES.................................................................................9
ELECTRICAL AND PEDICURE SPA COMPONENT SPECIFICATIONS ....................... 11
OPERATION AND CARE INSTRUCTIONS.................................................................... 12
Auto-Fill™:.............................................................................................................................12
JET COVER REMOVAL & INSTALLATION:................................................................... 14
JET HOUSING REMOVAL & INSTALLATION................................................................ 15
MASSAGE SYSTEM & REMOTE CONTROLLER:......................................................... 16
Safety Requirements for Pedicure Spas................................................................................18

3
____________________________________________________Safety Precautions
READ AND FOLLOW INSTRUCTIONS CAREFULLY
SAFETY PRECAUTIONS:
Warning THIS PRODUCT IS FOR INDOOR USE ONLY
DISCONNECT POWER SUPPLY CORD BEFORE SERVICING
This product is to be connected to a branch circuit outlet protected by a Class A GROUND FAULT CIRCUIT
INTERRUPTER (GFCI), and the GFCI shall be tested regularly for continued protection and correct operation. If a
Class A GFCI protected outlet is not available, DO NOT USE THIS PRODUCT! Please contact a licensed
electrician for installation of a Class A GFCI according to local electric codes, or equivalent.
Warning DO NOT USE if you are diabetic, have poor circulation, or if any area of your feet or legs
is inflamed or has an open sore. Consult your physician before using if you have any kind of
fungal infection, swelling, fracture or persistent pain.
Warning TO REDUCE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE
THIS UNIT UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME
•LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE
•UTILISER SEULEMENT A L’INTERIEUR
•COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE, AU NETTOYAGE
Warning 1. Excessive water temperature is dangerous and should be checked BEFORE use.
2. Maximum temperature of the water should never exceed 100 degrees F.
3. DO NOT STEP/ STAND IN FOOT BASIN.
4. Always enter and exit the Pedicure Spa slowly and carefully.
5. NEVER bring and / or operate any electrical devices into or near the Pedicure Spa.
6. Maximum load in spa chair is 250lbs (114kg).
Warning
If a crack in the GLASS BOWL occurs, DO NOT handle unless the proper attire and
equipment is used. Discontinue use of the bowl until proper replacement is arranged. You
may be held accountable for any injury that may occur. Lexor is not liable for any injury
that may occur.
STATES’ NOTICE

4
In the common wealth of most of the States, all pedicure spas shall be installed for Commercial usage in the
states, are required to have backflow preventer. This equipment shall be installed between the water inlets and
the spa at Salon’s cost.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
__________________________________________________Identifying Parts
Identifying Parts for Ultima® Model
(Pedicure Whirlpool with Massage System)
1. Head Rest
2. Chair Cushion with
Massage
3. Armrest Cushion
4. Massage Remote Control
5. Manicure-Tray (Optional)
6. Angelic Bowl
7. Footrest
8. Sani-Drain™ System with

5
Discharge On/Off Knob
9. Jet On/Off Knob & Auto-
Fill™
10. Hot/Cold Water Mixer
Valve
11. Flex Water Filler/Spray
Spout
12. Up/Down Armrest
13. Handbag (purse) Hook
14. Tub Light
15. Water Level Sensor
16. Drain Stopper
17. Pure-Flo™ Jet
18. Adjustable height Tech
Stool for Pedicure
_______________________________________________________Installation
SPA to SPA RECOMMENDED CLEARANCE:
Wall Clearance:

6
_
_____________________________________________________Installation
MANICURE TRAY/ ARMREST / BACK REST INSTALLATION
Up/Down Swinging Armrest:
1. Plug-In the manicure trays and attach the purse hook. (1 Supplied)
Back Rest:

7
1. To set backrest up: Lift up the backrest until a “Click” is heard. Make sure the lever is locked
before operating.
2. To fold down backrest: Lift up lever handle located on the left side / bottom of Chair.
_______________________________________________________Installation
Plumbing Connections:
Warning
Before any connection, pay attention to these subjects:
1. Debris or residue may become lodged into the Hot and Cold hoses during construction, which may clog
the Hot and Cold Mixer. To clean, drain a good amount of water from water hoses to bucket before
connecting them to the pedicure spa. Failure to do so may void your Warranty.
2. Hooking up a used Hot/Cold flex hose is not recommended since debris from broken rubber seal might
clog water mixer. Failure to do so may void your Warranty.
3. Backflow preventer: Due to differences in construction lay-out of your Salon and City’s plumbing code,
please contact your local Plumber to fulfill your needs as required. Backflow Preventers are not supplied
by the pedicure spa manufacturer.
4. Check valve is an optional part and supplied free of charge for your convenience. Factory is not liable for
this Check valve.
5. Maximum Inlet water pressure must be under 75 PSI.
Power Drain (optional):

8
_______________________________________________________Installation
Gravity Drain (No Drain Pump):
Plumbing Flow Pattern for Power Drain:

9
_______________________________________________________Installation
Plumbing Flow Pattern for Gravity Drain:
HOT AND COLD WATER SUPPLY LINES
Carefully connect ½” ID supply hoses (not provided) to fresh water sources. Shut-off valves (not
provided) should be utilized. Valves should be placed outside the tub for easy access.
Before water line connections, please follow below:
Determine if your spa chair is used for a new construction of a salon or a replacement spa chair.
1. New construction: Make sure to remove any and all debris and/or dust from current hot cold
water pipes before hooking up to spa. Suggested direction to remove debris: turn on water and
drain into a bucket or container. See illustration below:
2. Replacement Spa: Always use new hot/cold water hoses when connecting a new spa chair to
prevent debris, such as old rubber particles, from clogging drain.

10
______________________________________________________________Installation
CONNECT DRAIN WITH POWER DRAIN (PUMP) OR GRAVITY DRAIN (NO PUMP)
Using ¾” schedule 40 PVC (Power Drain) or 1 ¼” flex tube (Gravity Drain) and appropriate traps.
Connect drain to meet local plumbing codes.
Rubber connection to the drain should be removable for easy service and should not be permanent to
prevent damages.
Tabla de contenidos
Otros manuales de Spa de pedicura de Lexor