Lexor PRIVE PEDICURE SPA Manual de usuario


THE KEY TO SALON SUCCESS
PRIVE PEDICURE SPA USER MANUAL
WARNING: 1.This product is for indoor use only & is not recommended for use on carpet or wood floor.
2.This product must be connected to a circuit outlet protected by a class A GFCI.
3. O NOT USE if you have poor circulation, or if any area of your feet or legs has an open sore.
4. Maximum temperature of the water should never exceed 100 degrees F.
5. O NOT STEP or STAN IN THE FOOT BASIN.
6. O NOT operate any electrical devices near the pedicure spa.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
Table of Contents
IDENTIFYING PARTS FOR PRIVE® MODEL 2
WALL CLEARANCE & SPA TO SPA RECOMMENDED CLEARANCE 3
INSTALLATION OF PEDICURE SPA DOME 4
INSTALLATION OF PEDICURE SPA SEAT 5
INSTALLATION OF PLUMBING SYSTEM 8
INSTALLATION OF VENTILATION SYSTEM OPTIONAL) 11
ELECTRICAL AND PEDICURE SPA COMPONENT SPECIFICATIONS 12
PRE-OPERATIONAL SETUP 13
OPERATE AUTO-FILL / JET SWITCH 15
OPERATE DIGITAL CONTROL PANEL 16
RESET WATER SENSOR AND WATER LEVEL 17
MASSAGE SYSTEM & REMOTE CONTROLLER 19
DOME SPOTLIGHT REPLACEMENT
STEAMER REPLACEMENT
24
25
AF-CONTROL BOX REPLACEMENT
26
7. Maximum load in the spa chair is 250lbs (114kg).
PROPER INSTALLATION ACCOR ING TO THIS MANUAL IS REQUIRE . FAILURE TO O SO MAY RESULT IN
SERIOUS INJURY AN /OR WARRANTY WILL BE NULL. YOU MUST HAVE A LICENSE PLUMBER TO CONNECT THE
SPA AN WATER SYSTEM IN PLACE SAFELY.
STATES’ NOTICE
In the commonwealth of most states, all pedicure spas installed for commercial usage are required to have a
backflow preventer at the salon’s cost. This device shall be installed between the water inlet hose and the spout
RECEIVING AN INSPECTION: If missing parts or damages are found, please notify the carrier at once and
insist on a notation of the damage on the bill of lading. O NOT ISCAR THE SHIPPING BOX. If you give
the carrier a clear receipt for goods that have been damaged in transit, you do so at your own risk and expense.
DRAIN KNOB & AUTO-FILL /JET KNOB
REMOVING THE FRONT PANEL
FAUCET ASSEMBLY INSTRUCTION
21
22
20
1
REMOVING THE FOOTREST 27

Pedicure Spa with Massage System
1
2
3
4
5
6
10 12
15
17
19
18
14
21
13
7
9
11
8
16 20
16
1. ome spotlight
2. ome
3. Pillow
4. Back cushion with massage
5. Massage remote control
6. Armrest cushion
7. Seat cushion
8. Footrest with calf support
9. igital control panel
10. rain knob
11. Hot/Cold water mixer valve
12. Auto-fill/Jet knob
13. Aurora bowl
14. Handbag (purse) hook
15. Manicure tray
16. Hand spray spout
17. Ventilation inlet
18. ECOJETTM Magnetic drive
19. Safety device for steamer
20. Air ring therma Jet
21. Low profile pedicure stool prive
2
Identifying Parts for PRIVE® Model
IDENTIFYING PARTS

WALL CLEARANCE & SPA TO SPA RECOMMENDED CLEARANCE
3
VERY IMPORTANT:The wall clearance for dome-to-wall 0.5 inch / 1.25cm and base-to-wall
10 inch / 25.4cm are mandatory to give enough space for the unobstructed chair recline and
plumbing system connections. Failure to follow may result in serious damage to the spa
component and void the warranty.
INSTALLATION

INSTALLATION OF PEDICURE SPA DOME
1. L WER D ME ASSEMBLY
Step 1: Install lower-dome by inserting 2 mounting rods from lower dome into spa base frame
then secure 2 M8 x 45 bolts (attached on base). Locate and connect both ends of spotlight
power cables.
Step 2: Open the panel labeled “UPPER”. Install upper-dome by inserting 2 mounting rods from
upper-dome to lower-dome frame then secure 2 M8 x 20 bolts (in the accessory bag). Locate and
connect both ends of spotlight power cables. Re-install the panel.
2. UPPER D ME ASSEMBLY
Panel labeled
“UPPER”
2 M8 x 45 bolts
4
INSTALLATION

INSTALLATION OF PEDICURE SPA SEAT
1. F LD & UNF LD BACK-REST MASSAGE
“CLICK”
5
Raise the backrest until a “click” is heard. Make
sure the lever is locked before operating.
To fold down the backrest: Lift up lever handle
and push the backrest downward.
INSTALLATION

2. BACK CUSHI N ASSEMBLY
2
2
NOTE:
Wire & connector number 2 must be routed under the seat frame.
DON’T plug the +) connector of the number 2 into the -) connector of the number 1.
Install the back cushion by engaging the 2 bottom hooks
of cushion onto the shaft of massage frame. Position the
top of back cushion, then snap the fit joint of back
cushion to the crossbar of massage frame, press the
back cushion firmly on the massage frame to secure it.
Install the seat cushion by engaging the 2-rear hooks of
seat cushion onto the seat frame.
Position the seat cushion then snap the fit joint of seat
cushion to the seat frame. Press the seat cushion firmly
on the seat frame to secure it.
Connect the 2 connectors labeled “2” from the seat
cushion to the spa base.
3. SEAT CUSHI N ASSEMBLY
6
INSTALLATION

Position and line up both markers of the armrest and
seat frame connectors. Engage both sides into guide
joints. Horizontally rotate armrest counter clockwise
(clockwise with right armrest) to lock it in place.
Connect 2 connector labeled “1” between Right
Armrest and Spa Base.
lever of locking
device
Press
& Hold
1
1
A. Armrests Assembly
B. ArmRests Removal
4. ARMRESTS ASSEMBLY
isconnect the connector of the right armrest
labeled “1”.
Vertically rotate left armrest clockwise (counter
clockwise with right armrest). Press and hold lever
locking device to unlock the mechanism and
continue to rotate armrest clockwise (counter
clockwise with right armrest) to remove the
armrest.
Line-up markers
NOTE: Locate the maker line before assembling.
1
1
7
INSTALLATION

INSTALLATION OF PLUMBING SYSTEM
NOTE: The drainage and water supply system installation require a licensed plumber. etailed
instructions can be found in the manual book. Instructions and local plumbing codes need to be
carefully complied to pass the city inspections.
1. GRAVITY DRAIN
8
GRAVITY RAIN
1-¼” flex hose with removable connector is provided for easy
installation (optional)
Backflow preventer (not included)
(Optional device based on local
plumming code)
½” I cold water
½” I hot water
Vent
rainage pipe connect to waste system through
P-trap and vent.
Connect to sanitaryConnect to sanitary
Underground P-trap
1-½” drainage pipe
The gravity drainage installation should comply with SECTION 701.0, 2018 UPC.
P-trap, vent, and connectors should comply with SECTION 1001.1 and 1001.2 UPC.
An alternative code needs to be complied with by the states not adopting UPC.
●rainage system: SECTION 701.2 and 702.2 IPC (or local plumbing code).
●P-trap, vent, and connectors: SECTION 1002.1 and 1002.2 IPC (or local plumbing code).
The installer/plumber is responsible for obtaining and complying with the local plumbing code for
inspection. If any assistance is required from the vendor’s side, please contact our customer service.
PLUMBING SYSTEM

2. P WER DRAIN
The power drainage installation should comply with SECTION 807.1, 2018 UPC.
P-trap, vent, and connectors should comply with SECTION 1001.1 and 1001.2 UPC.
An alternative code needs to be complied with by the states not adopting UPC.
●rainage system: SECTION 701.2 and 702.2 IPC (or local plumbing code).
●P-trap, vent, and connectors: SECTION 1002.1 and 1002.2 IPC (or local plumbing code).
The installer/plumber is responsible for obtaining and complying with the local plumbing
code for inspection. If any assistance is required from the vendor’s side, please contact
our customer service.
9
½” I cold water ½” I hot water
¾” PVC drain
¾” drain pipe
¾” coupling
Check valve
PLUMBING SYSTEM
Tabla de contenidos
Idiomas:
Otros manuales de Spa de pedicura de Lexor