Short instructions IT 6300 Leuze electronic Page 2
Preface
We congratulate you on the purchase of one of the most powerful hand-held scanners. This document is
intended to provide information on the handling and use of the IT 6300 DPM produced by Leuze electronic.
It includes explanations of the most important information necessary for operation. In addition, the most
important connection types are explained and information is provided on programming with the aid of
codes.
Additional information can be found in the online help system, which is installed together with the setup tool.
Contents
PREFACE ....................................................................................................................................................................... 2
CONTENTS .................................................................................................................................................................... 2
SCOPE OF DELIVERY ................................................................................................................................................ 3
•IT 6300 PART NO. 50105380............................................................................................................................... 3
INSTALLATION ........................................................................................................................................................... 3
Switching off the computer ....................................................................................................................................... 3
CONNECTING THE HAND-HELD SCANNER ...................................................................................................................... 3
Connecting the cable for the IT 6300 ....................................................................................................................... 4
Testing the scanner................................................................................................................................................... 4
SPECIFICATIONS ........................................................................................................................................................ 4
PIN ASSIGNMENTS OF THE CONNECTION CABLE............................................................................................................. 4
TTL-RS232 cable/ext IT 6300 Part No. 501 05422 ................................................................................................ 4
PS2 cable/ext IT 6300 Part No. 50105424 ............................................................................................................. 5
USB cable IT 4xxx Part No. 50103404................................................................................................................... 5
READING FIELDS ........................................................................................................................................................... 6
IT 6300 DPM............................................................................................................................................................ 6
RESETTING THE IT 6300 TO FACTORY SETTINGS ........................................................................................... 7
CONFIGURATION ....................................................................................................................................................... 7
IT 6300 ON THE SERIAL PC INTERFACE......................................................................................................................... 8
With voltage supply via power supply unit with TTL-RS232 cable/ext IT 6300 Part No. 50105422........................ 8
Configuration for the Leuze standard protocol........................................................................................................ 9
IT 6300 ON MA 41 DP-K OR MA 41 IS ....................................................................................................................... 9
IT 6300 ON MA 41 DP-K OR MA 41 IS ..................................................................................................................... 10
IT 6300 TO MA 21...................................................................................................................................................... 11
IT6300 TO PS2 INTERFACE ......................................................................................................................................... 12
IT 6300 TO USB INTERFACE (KEYBOARD EMULATION) .............................................................................................. 13
IT 6300 TO USB INTERFACE (COM PORT EMULATION).............................................................................................. 14
TRIGGER...................................................................................................................................................................... 15
TROUBLESHOOTING .................................................................................................................................................... 15
TYPE OVERVIEW...................................................................................................................................................... 16
ACCESSORIES............................................................................................................................................................ 16
CONNECTING TO LEUZE MULTINET PLUS .................................................................................................................... 17
CONNECTING TO PROFIBUS ......................................................................................................................................... 17
CONNECTING TO INTERBUS ......................................................................................................................................... 17

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 3
CODES FOR FAST CONFIGURATION .................................................................................................................. 18
Scope of delivery
•IT 6300
Part No. 50105380
1. Hand-held scanner IT 6300 IDP 351 S
2. CD-ROM
An overview of the types can be found on page 16
For accessories, see page 16
Installation
Switching off the computer
Information on switching off and shutting down the connected computer - which must always be performed
before connecting peripheral devices, such as a scanner - can be found in the appropriate operating
instructions for your computer.
Connecting the hand-held
scanner
Shown in the figure below are the individual steps for
installing the cable on the scanner; these steps are
described in the following.
Cable latch
Fastening clip

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 4
Connecting the cable for the IT 6300
1. To secure the interface cable to the scanner, proceed as follows: plug the RJ 41 connector into the
socket on the bottom of the hand-held scanner, now use a Phillips screwdriver to secure the supplied
clip for locking the cable.
2. Connect the interface cable to the appropriate connection socket on the computer.
3. You will need a power supply unit for the voltage supply. Connect this power supply unit to the interface
cable.
4. Connect the power supply unit to the power socket.
5. Check the operational readiness of the scanner by pointing the scanning surface towards a flat surface
and pulling the trigger. A green target line as well as the red illumination should now be visible. Now
scan a sample label. The scanner emits an audible signal to confirm that the label has been read; if
necessary, the data are now passed on to the computer.
Testing the scanner
The adjacent bar code is for testing the scanner,
the module size is 0.5 mm (20 mil)
Code 39 bar code sample
Specifications
The technical data can be found in the data sheet for the IT 6300.
Pin assignments of the connection cable
TTL-RS232 cable/ext IT 6300 Part No. 501 05422
Pin assignments of the 9 pin D-sub socket (female) for cable 42206139-04
Pin number Signal Designation
1 Shield Shield
2 TX Transmit data
3 RX Receive data
5 GND Signal ground
7 CTS Clear to send
8 RTS Request to send
Pin at power supply unit
connection
Signal Designation
1 VCC IN 4.5…12 V DC
2 GND Ground
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403.

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 5
PS2 cable/ext IT 6300 Part No. 50105424
Pin assignments of the Mini DIN socket or connector for cable 42206416-01
Pin connector Pin socket Signal Designation
1 - PC data PC data line
2 2 NC Not used
3 3 GND Signal ground
4 4 VCC IN 5 Volts DC
5 - PC Clock PC clock line
6 6 NC Not used
- 1 KB Data Keyboard data line
- 2 KB Clock Keyboard clock line
Pin at power supply unit
connection
Signal Designation
1 VCC IN 4.5…12 V DC
2 GND Ground
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403.
USB cable IT 4xxx Part No. 50103404
Pin assignments of USB type A connector for cable 42206132-03
USB type A connector Signal Designation
1 VCC IN 5 Volts DC
2 Data - Data line -
3 Data - Data line +
4 GND Signal ground
Pin at power supply unit
connection
Signal Designation
1 VCC IN 4.5…12 V DC
2 GND Ground
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403.

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 6
Reading fields
IT 6300 DPM

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 7
Resetting the IT 6300 to factory settings
To reset all parameters to factory settings, scan the bar code shown below.
Attention: All settings are lost!!!
Configuration
The hand-held scanner can always be configured using bar codes. To do this, first select the bar code in
the manual and then actuate the trigger button in order to read the code. The configuration is then
immediately accepted and executed.
Several of the most important configurations are listed in the following.
A second option is to configure the hand-held scanner with the USB and RS232 interfaces with the aid of
the "6300 Series Setup Tool" PC program. You can download and install this program from our homepage
at www.leuze.de. The program can be used to make settings and transfer them to the hand-held scanner.
The configuration can also be stored so that it can be reused at a later time.
The standard applications are described in the following; each is summarised on a separate page.

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 8
IT 6300 on the serial PC interface
With voltage supply via power supply unit with TTL-RS232 cable/ext IT 6300
Part No. 50105422
Please connect the IT 6300 acc. to the adjacent figure.
Required parts:
1x 501 05 380 IT 6300 IDP 315S
1x 501 05 422 Cable TTL-RS232/ext for IT 6300
1x 501 03 403 Power supply unit
Pin assignments of the 9 pin D-sub
socket (female) for cable 42206139-04
Pin number Signal Designation
1 Shield Shield
2 TX Transmit data
3 RX Receive data
5 GND Signal ground
7 CTS Clear to send
8 RTS Request to send
Pin at power supply unit
connection
Signal Designation
1 VCC IN 4.5…12 V DC
2 GND Ground
The proper power supply unit for the IT 6300 (230V/50Hz) has part no. 501 03403.
RS 232 transmission with 38400 baud, 8 data bits, 1 stop bit, no parity, postfixes CR/LF.

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 9
Configuration for the Leuze standard protocol
Leuze standard protocol:
RS 232 with 9600 baud, 8 data bits, 1 stop bit, no parity, prefix STX and postfixes CR/LF
Factory setting
Return the IT 6320 to the base station to apply the settings. This procedure is concluded
with audible confirmation signals.
To configure the device, please scan the codes in the specified order.
The read operation is confirmed by an audible signal.
RS 232 interface c
RS 232 baud rate: 9600 baud d
Prefix STX e
The setup tool must be used in order to configure the prefix.
The following settings must be performed:
•Activate the Formatting Enabled check box.
•Please enter \002 in the Leading Text field.
•Select Full string and click Add.
•Activate the CR/LF check box.

Leuze electronic
Short instructions IT 6300 Leuze electronic Page 10
IT 6300 on MA 41 DP-K or MA 41 IS
RS 232 transmission with 9600 baud, 8 data bits, 1 stop bit, no parity, postfixes CR/LF.
Required parts:
1x 501 05 380 IT 6300 IDP 315 S
1x 501 05 422 Cable TTL-RS232/ext for IT 6300
1x 501 03 403 Power supply unit
1x 500 35 421 KB 021 Z
1x 500 33 638 MA 41 DP-K for Profibus
(for Interbus: 500 28 994 MA 41 IS or 500 30 085 MA 41 IS PDP)
Pin assignments KB021 Z
Core colour Signal Terminal in MA 41:
brown (RXD) 2
white (TXD) 1
blue (GND) 4
red (VCC)
black (GND)
bare (shield) (PE) 21
Please connect the IT 6300 acc. to the figure below.
Configuration
Connection to MA41 in standard setting
Tabla de contenidos
Otros manuales de Escáner de Leuze electronic

Leuze electronic
Leuze electronic DCR 202i Manual de usuario

Leuze electronic
Leuze electronic RSL 420P Manual de usuario

Leuze electronic
Leuze electronic CU405-2M12 Manual de usuario

Leuze electronic
Leuze electronic rotoScan ROD4 plus Series Manual de usuario

Leuze electronic
Leuze electronic RSL 410 Manual de usuario

Leuze electronic
Leuze electronic RSL 450P Manual de usuario

Leuze electronic
Leuze electronic RS4 Manual de usuario

Leuze electronic
Leuze electronic RSL 420 Manual de usuario

Leuze electronic
Leuze electronic IT 1910i Manual de usuario

Leuze electronic
Leuze electronic KRTL 3B Manual de usuario