KT-Elektronik SOL3-7 Manual de usuario

Solar controller
SOL3-7
Installation and operating
manual
Firmware version 1.07
April 2011

Installation and operating manual KT-Elektronik
Warranty
We permanently enhance our products, therefore we reserve the right to make changes
to our products at any time and without prior notice.
We take no responsibility for the accuracy or completeness of this manual. No liability
can be accepted for the use of our products for a buyer specific purpose. Buyer claims,
especially claims for damages including lost profits or other financial losses are
excluded. This does not apply if the damage caused by intent or gross negligence. In
case of negligent violations of major contractual obligations, our liability is limited to the
foreseeable damage
Security advices
Only qualified personnel that is familiar with installation and
commissioning of this product is allowed to mount and put into
operation the device. Appropriate shipping and storage are assumed.
The product is designated for use in heavy current equipment.
Installation and maintenance have to be performed according to the
corresponding safety regulations.
2EB_37387_SOL3-7_EN003

KT-Elektronik SOL3-7
Table of contents
1 Operation ...................................................................................................................... 6
1.1 Controls .................................................................................................................. 6
1.1.1 Rotary pushbutton ........................................................................................... 6
1.1.2 Rotary switch ................................................................................................... 7
1.2 Operating modes for heating circuit ........................................................................ 8
1.3 Display .................................................................................................................... 9
1.4 Retrieving data – Information level ....................................................................... 11
1.5 Setting the system time ........................................................................................ 12
1.6 Adjust usage schedule settings ............................................................................ 13
1.7 Setting the party mode (heating circuit/auxiliary heating) ..................................... 15
1.8 Access advanced information level ...................................................................... 16
1.8.1 Setting holidays .............................................................................................. 17
1.8.2 Setting vacation times .................................................................................... 17
1.9 Operation level stucture ....................................................................................... 19
2 Commissioning ............................................................................................................ 20
2.1 Setting the system variant ID ................................................................................ 20
2.2 Activate and deactivate functions ......................................................................... 21
2.3 Edit settings .......................................................................................................... 23
2.4 Sensor calibration ................................................................................................. 24
2.5 Reset to factory default settings ........................................................................... 25
3 Manual operating mode .............................................................................................. 26
4 System variants ........................................................................................................... 27
4.1 Extending the basic system variant representations ............................................ 36
5 Solar circuit functions .................................................................................................. 39
5.1 Basic Control function ........................................................................................... 39
5.2 Storage ................................................................................................................. 41
5.3 Swimming pool ..................................................................................................... 42
5.4 Collector return flow sensor, Collector flow sensor .............................................. 43
5.5 Measurement of solar power and solar energy .................................................... 44
5.6 Rotation speed control .......................................................................................... 46
5.7 Collector overheating protection ........................................................................... 47
5.8 Collector minimum temperature ........................................................................... 48
5.9 Start up function ................................................................................................... 48
5.10 Forced pump operation (blocking protection) ..................................................... 48
5.11 Collector Antifreeze ............................................................................................ 49
EB_37387_SOL3-7_EN003 3

Installation and operating manual KT-Elektronik
5.12 Two collector arrays ........................................................................................... 50
5.13 External heat exchanger ..................................................................................... 50
5.14 Auxiliary heating with secondary heat generator ................................................ 51
6 Heating circuit functions .............................................................................................. 52
6.1 Prescribing the room temperature set-points ....................................................... 52
6.2 Weather-compensated control ............................................................................. 52
6.2.1 Gradient characteristic .................................................................................. 52
6.2.2 4-point characteristic ...................................................................................... 54
6.3 3-point control ....................................................................................................... 56
6.4 Two-point control .................................................................................................. 56
6.5 Regulating by fixed value ..................................................................................... 57
6.6 Underfloor heating/screed drying ......................................................................... 57
6.7 Deactivation depending on the outdoor temperature ........................................... 59
6.7.1 OT deactivation temperature for daytime operating mode ............................. 59
6.7.2 OT deactivation temperature for night-time operating mode ......................... 59
6.7.3 OT activation temperature for daytime operating mode ................................. 59
6.7.4 Summer operating mode (OM) ...................................................................... 60
6.8 Delayed outside temperature compensation ........................................................ 60
6.9 Remote operation ................................................................................................. 61
6.10 Optimization ........................................................................................................ 61
6.11 Raise return flow of external heating system ..................................................... 62
6.11.1 Main principle ............................................................................................... 62
6.11.2 Implementation ............................................................................................ 63
7 Domestic water circuit functions .................................................................................. 64
7.1 Domestic water heating in storage tank ............................................................... 64
7.2 Thermal Disinfection of the storage tank .............................................................. 64
8 System wide functions - all system variants ................................................................ 65
8.1 Automatic summer/winter switching ..................................................................... 65
8.2 Antifreeze ............................................................................................................. 65
8.3 Locking manual operating mode .......................................................................... 66
8.4 Locking the rotary switch ...................................................................................... 66
8.5 Enter a valid individual access code ..................................................................... 66
8.6 Temperature difference controller ........................................................................ 67
9 Malfunction .................................................................................................................. 68
9.1 Error list ................................................................................................................ 68
9.2 Sensor failure ....................................................................................................... 68
4EB_37387_SOL3-7_EN003

KT-Elektronik SOL3-7
9.3 Temperature monitoring ....................................................................................... 69
9.4 Error status register .............................................................................................. 69
9.5 SMS delivery in case of a system failure .............................................................. 70
10 Communication ........................................................................................................ 71
10.1 Communication module KOM232PC ................................................................. 72
10.2 Communication module iCon485 ...................................................................... 72
10.3 Communication module KOM232M ................................................................... 74
10.4 Data Modem DataMod11 .................................................................................. 75
10.5 ModBus-MBus-Gateway .................................................................................... 76
10.6 Description of the adjustable communication settings ....................................... 76
10.7 Memory module ................................................................................................. 77
10.8 55Viewer for visualization and remote maintenance. ........................................ 78
10.9 Data Logging ..................................................................................................... 79
11 Mounting ................................................................................................................... 80
12 Electrical connection ................................................................................................. 82
12.1 Notes for wire installation ................................................................................... 82
12.2 Surge Protection Measures ................................................................................ 82
12.3 Connecting the controller .................................................................................... 82
12.3.1 Connecting the sensors ............................................................................... 83
12.3.2 Connecting the pumps ................................................................................. 83
12.3.3 Legend for connection diagram ................................................................... 83
12.3.4 Wiring diagram ............................................................................................. 84
12.3.5 Terminal assignment for Outputs ................................................................. 85
12.3.6 Terminal assignment for inputs .................................................................... 88
13 Appendix ................................................................................................................... 89
13.1 Function block lists ............................................................................................. 89
13.2 Parameter list ..................................................................................................... 93
13.3 Resistance values ............................................................................................ 103
13.4 Technical specifications .................................................................................... 104
13.5 Accessories ...................................................................................................... 105
13.6 Function block settings in configuration levels ................................................. 106
13.7 Abbreviations .................................................................................................... 107
13.8 Access codes ................................................................................................... 108
13.9 Notes ................................................................................................................ 109
EB_37387_SOL3-7_EN003 5

Installation and operating manual KT-Elektronik
1 Operation
The controller is factory-provided with standard temperature settings and timing
programs and therefore ready for use.
The current date and time have to be set at initial operation of the controller (Chapter
1.5).
1.1 Controls
The operational controls are located on the front side of the controller.
1.1.1 Rotary pushbutton
Rotary pushbutton
Turn :
Display, select settings and function blocks
Push :
confirm selection or setting
6EB_37387_SOL3-7_EN003

KT-Elektronik SOL3-7
1.1.2 Rotary switch
The rotary switch is used to select the operating mode on the left hand and the basic
settings of the controller on the right hand.
Rotary switch – operating mode
Control on, display informations about
operating behaviour of unit (standard position)
Turning off the control functions
(Controller remains in operation)
Manual operating mode:
manual switching of pumps and valves,
position presetting in percent
Rotary switch – Settings
Solar-Turn-on threshold
Solar-Turn-off threshold
Scheduled time ranges and operating modes for
heating circuit (1), aux. heating (2) and hot water
circulation (3)
Party mode
System time:
Setting time, date and year
Configuration and settings level
EB_37387_SOL3-7_EN003 7

Installation and operating manual KT-Elektronik
1.2 Operating modes for heating circuit
The operation of the heating circuit can be affected depending on time and day of week.
Thereto different set-points for night and day exist. A usage schedule determines when
to operate in day-time OM or night-time OM. It is possible to deactivate schedules
(without deleting them) and to specify manually to operate permanently in day-time or
night-time operating mode.
Icons on the display indicate the current OM for each function of the controller:
Daytime operating mode (nominal operation)
Values are permanently adjusted to meet the set-points entered for nominal operating
mode regardless of scheduled time ranges or summer operating mode settings.
Night-time operating mode (reduced operation)
Values are permanently adjusted to meet the set-points entered for reduced operation
regardless of scheduled time ranges.
Normal operating mode off
Normal operating mode is deactivated regardless of the scheduled time ranges. Only
equipment anti-freeze is ensured (if activated).
Automatic operating mode
The controller automatically switches between both modes depending on the time.
Manual operating mode
Manual control of valves and pumps (Chapter 3).
8EB_37387_SOL3-7_EN003

KT-Elektronik SOL3-7
1.3 Display
During operation, the display shows the current time as well as information about the
status of the controller. The usage periods are represented by black squares below the
row of numbers. Symbols mark the operational status of the controller.
Holiday operating
mode (OM)
Vacation OM
Malfunction
Frost protection OM
1Heating circuit 2Solar circuit 3Auxiliary heating,
domestic water
circuit
Automatic operating
mode Automatic operating
mode Automatic operating
mode
Night-time operation Night-time operation
Daytime Operation Manual operating mode Daytime Operation
Manual operating mode Stand-by OM Manual operating mode
Stand-by OM Collector pump CP1 Stand-by OM
Circulation pump UP1 Collector heat exchanger
pump, CTP Circulation pump ZP
Valve M1 OPEN Storage tank pump SP1 Aux. heating NH
Valve M1 CLOSED Collector switching
valve CUV
Collector pump CP2
Temperature
difference switch TdS
Storage switching
valve SUV
Storage pump SP2
EB_37387_SOL3-7_EN003 9

Installation and operating manual KT-Elektronik
The following applies to the icon of the collector pump(s):
Icon or Description
Icon off Pump off
Icon flashes briefly Condition to turn on the pump is met but the
pump is still off because of the minimum idle
time.
Icon is on but disappears for a
short time in intervals
Condition to turn off the pump is met but the
pump is still running because of the minimum
running time.
Icon on Pump is running
The controller status can be viewed at operating mode level (Chapter 1.4 ).
10 EB_37387_SOL3-7_EN003
Otros manuales para SOL3-7
2
Tabla de contenidos
Otros manuales de Enrutador de red de KT-Elektronik
Manuales populares de Enrutador de red de otras marcas

NETGEAR
NETGEAR FS526T - Switch Manual de usuario

Korenix
Korenix JetNet 5710G Series Manual de usuario

Automated Logic
Automated Logic ZN551 Manual del propietario

Cisco
Cisco ASR 1000 Series Manual del operador

EnGenius
EnGenius ESR-9710 Manual de usuario

Cisco
Cisco 805 Series Instrucciones de funcionamiento y seguridad