Kohler 1263840 Instrucciones de montaje

Installation and Care Guide
Amplifier
Français, page“ Français-1”
Español, página“ Español-1”
1263840
1298482-2-A

Specifications
Ambient Temperature Max 104°F (40°C)
Maximum Relative Humidity 90% non-condensing
Electrical Service 120 VAC, 50/60 Hz, 1.3 A Max
Power Cable Length 36″(914 mm)
Data Cable Length 6’ (1.83 m)
Output Power 90 Watts total
Frequency Response 20 Hz - 18 kHz +/- 3dB
Signal/Noise Ratio >75 dB
Total Harmonic Distortion <0.1% at 1 Watt, <1% at full output
power
Tools and Materials
Before you Begin
WARNING: Risk of electric shock. Disconnect power before
servicing.
CAUTION: Risk of product damage. The amplifier is rated to
operate in temperatures up to 104°F (40°C). Do not install near heat
sources (such as radiators or heat registers) or in any location where
the temperature may exceed 104°F (40°C).
NOTICE: This product is not water-resistant. Do not install in a
location where excessive moisture, high humidity levels, or
condensation are present.
NOTICE: Follow all electrical and building codes.
• Wire Cutter/Stripper
Plus:
1298482-2-A 2 Kohler Co.

Before you Begin (cont.)
NOTICE: Provide unrestricted service access to the amplifier.
NOTICE: Provide a minimum of 6″(152 mm) of space around the
amplifier for proper air flow.
Determine amplifier and speaker locations before beginning
installation. Test the BLUETOOTH
®
range between the amplifier
and your wireless device when determining amplifier location.
Under normal conditions, the maximum range is 30’ (9.14 m).
The amplifier can be mounted in any orientation. Use the
supplied brackets or rubber feet to accommodate your mounting
configuration.
Locate the amplifier within close proximity to a 15 A 120 V
electrical outlet. Install a GFCI or RCD electrical outlet within the
stud framing and within 24″(610 mm) of the amplifier.
A qualified electrician should install any electrical outlet.
Install the electrical outlet prior to installing the amplifier.
This amplifier complies with CE, FCC, IC, and RoHS.
Kohler Co. 3 1298482-2-A

1. Preparation
Plan the location of the amplifier to allow access to the front and
back ports.
To play your personal music files, a wireless BLUETOOTH device
or a device with a 3.5 mm stereo cable connection is required.
Allow adequate reach for wires between the bath and the
amplifier.
Make sure the status LED will be visible after installation.
NOTICE: The circular auxiliary-in port is not an ethernet
communication port. Do not connect an ethernet network to the
auxiliary-in port. Use the auxiliary-in port only for a standard
accessory.
Status LED
AC Power Supply
User Interface
Amplifier
Auxiliary-In Cable
Chromatherapy Cable In
Transducers
1298482-2-A 4 Kohler Co.

2. Installation
CAUTION: Risk of product damage. The amplifier is rated to
operate in temperatures up to 104°F (40°C). Do not install near heat
sources (such as radiators or heat registers) or in any location where
the temperature may exceed 104°F (40°C).
NOTICE: Mount the amplifier in a dry location, and provide a
minimum of 6″(152 mm) of space for proper air flow.
NOTE: Choose the mounting location to best suit the location of the
incoming transducer wires and other cables.
NOTE: Make sure the status LED will be visible after installation.
Mounting Options
Wall-mount: Secure the amplifier in an upright position using the
mounting brackets, anchors, and short screws provided.
Cabinet-mount: Secure the amplifier in an upright position using
the mounting brackets and short screws provided.
Cabinet-Mount
Under-MountSurface-Mount
Wall-Mount
Kohler Co. 5 1298482-2-A

Installation (cont.)
Surface-mount: Attach the four rubber feet to the underside of
the amplifier to protect against scratching your shelf or
countertop surface.
Under-mount: Secure the amplifier in position using the
mounting brackets and short screws provided.
Bracket Installation
Position the amplifier with attached brackets in the desired
location.
Mark the bracket hole locations with a pencil.
Drill pilot holes or insert anchors as needed at the marked
locations.
Secure the brackets using the four screws provided.
1298482-2-A 6 Kohler Co.

3. Amplifier Connection
NOTE: The transducer terminals and wires are numbered to
identify the correct connections. When required, the amplifier can be
removed to aid in the wire connection process.
NOTE: A data cable is provided to connect the amplifier to the user
interface.
NOTICE: The circular auxiliary-in port is not an ethernet
communication port. Do not connect an ethernet network to the
auxiliary-in port. Use the auxiliary-in port only for a standard
accessory.
Disconnect the power from the amplifier.
If equipped, connect the chromatherapy connector from the bath
to the chromatherapy connection on the amplifier.
Connect the transducer wires to the transducer terminals on the
amplifier. The white wires with black stripes are connected to the
positive (+) terminals, and the solid white wires are connected to
the negative (-) terminals.
Connect the clear connector of the user interface cable to the
amplifier user interface connection.
If used, connect the auxiliary-in cable to the auxiliary-in port on
the amplifier.
Reconnect the power to the amplifier.
Verify that the status LED turns on.
Power
Cable
Transducer
Terminals
User Interface
Connection
BACKFRONT
Auxiliary-In
Port
Chromatherapy
Connection
Status LED
Kohler Co. 7 1298482-2-A

4. Operation
When using the auxiliary-in, set your music device to midrange
volume after connecting to the amplifier, but before sending an
audio signal from the device.
To listen to a BLUETOOTH source, go to the AUX screen of the
User Interface. Activate by pressing the AUX icon.
A wireless BLUETOOTH source will override an auxiliary-in
source.
When listening to an auxiliary-in source, a tone will be heard
when a BLUETOOTH device is paired with the amplifier. The
tone indicates that the auxiliary-in source is no longer active.
To listen to an auxiliary-in source, the BLUETOOTH source must
be un-paired from the amplifier.
When listening to a BLUETOOTH device which is paired with the
amplifier, a tone will be heard when the BLUETOOTH device has
unpaired from the amplifier and is no longer active.
Status LED Light
Yellow blink = Amplifier error: Contact Kohler Customer Service.
Blue blink = Stand-by mode: Normal operation - No
BLUETOOTH connection.
Blue solid = Normal operation: BLUETOOTH receiver is paired
with a device.
Green blink = User interface error - For example, loose or
disconnected cable.
3.5 mm Stereo Input
Power
Cable
Transducer
Terminals
User Interface
Connection
BACKFRONT
Auxiliary-In
Port
Chromatherapy
Connection
Status LED
1298482-2-A 8 Kohler Co.

Operation (cont.)
A wired audio device can be connected to the auxiliary-in port on
the amplifier.
Audio input may be slightly delayed when a device is initially
connected.
Wireless Input
Once a BLUETOOTH device is paired, the LED will be solid blue
and the audio input will fade-in.
On the BLUETOOTH user device, the amplifier will display as
″VibrAcoustic″.
If a BLUETOOTH pin number is required, use ″0000″.
NOTE: For more information on system operation, refer to the
Homeowner’s Guide.
Troubleshooting
IMPORTANT! Turn off the power supply before performing any
maintenance.
NOTE: For service parts information, visit your product page at
www.kohler.com/serviceparts.
This troubleshooting guide is for general aid only. For service and
installation issues or concerns, call 1-800-4KOHLER.
Troubleshooting Table
Symptoms Probable Cause Recommended Action
1. One or more
transducers do
not produce
sound.
A. Transducer wire is
not connected
properly.
A. Make sure the wires
are properly
connected to the
amplifier. Each
transducer has a
white with black
wire which is the
positive (+) lead, and
a solid white wire
which is the negative
(-) lead.
Kohler Co. 9 1298482-2-A

Troubleshooting (cont.)
Troubleshooting Table
Symptoms Probable Cause Recommended Action
B. Damaged
transducer wires. B. The bath has six
transducers with
cables that are
permanently
attached. Inspect the
six transducers for
frayed, cut, or loose
wires. Contact Kohler
Customer Service for
assistance.
C. Transducer is
missing, loose, or
not attached.
C. If any one of the six
transducers is
missing, loose, or not
attached to the bath,
contact Kohler
Customer Service for
assistance.
2. The music
stops even
though a song
is properly
selected, and
the status
indicator light
is blinking
yellow.
A. Thermal shut
down. A. Shut down the
system for one hour
to allow the unit to
cool. Make sure the
area where the unit
is installed does not
exceed 104°F (40°C).
Restart the system.
The LED status
indicator should be
solid blue.
B. Amplifier error. B. Call Kohler
Customer Service if
the amplifier LED
status indicator is
blinking yellow after
the system has been
restarted.
3. The status LED
is not
illuminated.
A. Power supply is
not plugged into
the outlet.
A. Plug the power
supply into the
outlet.
B. Power supply
connection to the
amplifier is loose
or disconnected.
B. Check power supply
connection to the
amplifier and
reconnect if needed.
1298482-2-A 10 Kohler Co.