Knick Protos LDO 3400-170 Manual de usuario

Latest Product Information: www.knick.de
Protos 3400(X)
Process Analysis System
Protos LDO 3400-170 Measuring Module
For Optical Oxygen Measurement
in Liquids and Gases
The Art of Measuring.
Aktuelle Produktinformation: www.knick.de
Analysenmesssystem
Protos 3400(X)
Betriebsanleitung Messmodul Protos CONDI 3400 (X)-051
zur Leitfähigkeitsmessung mit induktiven Sensoren
Deutsch
The Art of Measuring.
Aktuelle Produktinformation: www.knick.de
Analysenmesssystem
Protos 3400(X)
Betriebsanleitung Messmodul Protos CONDI 3400 (X)-051
zur Leitfähigkeitsmessung mit induktiven Sensoren
Deutsch
User Manual
English

Trademarks
The following trademarks are used in this manual without further marking:
CalCheck®, Calimatic®, Protos®, Sensocheck®, Sensoface®, ServiceScope®, Unical®, VariPower®, Ceramat®,
SensoGate®
are registered trademarks of Knick Elektronische Messgeräte GmbH & Co. KG, Germany
Memosens®
is a registered trademark of
Endress+Hauser Conducta GmbH & Co. KG, Germany
Knick Elektronische Messgeräte GmbH & Co. KG, Germany
SMARTMEDIA®
is a registered trademark of Toshiba Corp., Japan
©2017 Subject to change without notice
Return of Products under Warranty
Please contact our Service Team before returning a defective device. Ship the cleaned device to
the address you have been given. If the device has been in contact with process fluids, it must be
decontaminated/disinfected before shipment. In that case, please attach a corresponding certificate,
for the health and safety of our service personnel.
Disposal
Please observe the applicable local or national regulations concerning the disposal of
“waste electrical and electronic equipment”.
Knick
Elektronische Messgeräte GmbH & Co. KG
Beuckestr. 22
14163 Berlin, Germany
Phone: +49 30 801 91 - 0
Fax: +49 30 801 91 - 200
Web: www.knick.de
Email: [email protected]

3
Table of Contents
Protos LDO 3400-170 Module
Return of Products under Warranty .................................................................................... 2
Disposal ......................................................................................................................................... 2
Trademarks ................................................................................................................................... 2
Intended Use.................................................................................................... 6
Conformity with FDA 21 CFR Part 11.................................................................................. 6
Safety Information .......................................................................................... 7
Software Version......................................................................................................................... 8
Modular Concept ....................................................................................................................... 9
Short Description .......................................................................................... 10
Short Description: FRONT Module ....................................................................................10
Short Description: Menu Structure....................................................................................11
Short Description: BASE Module........................................................................................13
Terminal Plate................................................................................................ 14
Inserting the Module .................................................................................... 15
Wiring ............................................................................................................. 17
Menu Selection.............................................................................................. 18
Menu Structure.............................................................................................. 18
Passcode Entry............................................................................................... 19
Changing a passcode.....................................................................................................19
Configuring the Measurement Display ....................................................... 20
Calibration / Adjustment .............................................................................. 22
Recommendations for Calibration.....................................................................................23
HOLD Function During Calibration ...................................................................................24
Automatic Calibration in Water...........................................................................................26
Automatic Calibration in Air.................................................................................................28
Product Calibration (Calibration with Sampling) ........................................................30
Zero Correction.........................................................................................................................32
Parameter Setting: Operating Levels .......................................................... 33
Administrator Level .................................................................................................................33
Operator Level...........................................................................................................................33
Viewing Level.............................................................................................................................33

4
Table of Contents
Protos LDO 3400-170 Module
Parameter Setting: Locking a Function............................................................................34
Activating Parameter Setting ..............................................................................................35
Documenting Parameter Setting .......................................................................................36
ProgaLog 3000 Software (Option) forConfiguration and Documentation .......38
Configuration using "ProgaLog 3000".....................................................................41
Setting the Sensor Data Parameters............................................................ 42
Sensoface ....................................................................................................................................47
Logbook.......................................................................................................................................48
Factory Setting..........................................................................................................................48
Configuring a Current Output.............................................................................................51
Current Outputs: Characteristics ........................................................................................52
Output Filter...............................................................................................................................54
NAMUR Signals: Current Outputs ......................................................................................55
NAMUR Signals: Relay Contacts..........................................................................................56
Relay Contacts: Protective Wiring ......................................................................................57
Relay Contacts, Usage ............................................................................................................58
Relay Contacts: Sensoface Messages................................................................................59
Rinse Contact.............................................................................................................................60
Icons in the Measurement Display ....................................................................................61
Limit Value, Hysteresis, Contact Type................................................................................61
OK1,OK2 Inputs: Specifying the Level..............................................................................62
Switching Parameter Sets via OK2.....................................................................................63
Selecting Parameter Set (A, B) via OK2 Input ................................................................63
Signaling Active Parameter Set via Relay Contact.......................................................63
Maintenance .................................................................................................. 65
Diagnostics Functions................................................................................... 66
Point of Meas Description.....................................................................................................66
Logbook.......................................................................................................................................66
Device Description ..................................................................................................................67
FRONT Module..........................................................................................................................67
BASE Module..............................................................................................................................67
Sensor Monitor..........................................................................................................................68
Cal Record...................................................................................................................................69

5
Table of Contents
Protos LDO 3400-170 Module
Sensor Network Diagram......................................................................................................69
CIP/SIP Cycles, Autoclaving Counter.................................................................................70
Setting Diagnostics Messages as Favorite ......................................................................71
Message List...............................................................................................................................73
Specifications................................................................................................. 78
Appendix:....................................................................................................... 81
Minimum Spans for Current Outputs ...............................................................................81
Index............................................................................................................... 86

6
Intended Use
In their directive “Title 21 Code of Federal Regulations, 21 CFR Part 11,
Electronic Records; Electronic Signatures“ the US American health agency FDA
(Food and Drug Administration) regulates the production and processing of
electronic documents for pharmaceutical development and production.
This results in requirements for measuring devices used for corresponding
applications. The following features ensure that the Protos 3400 modular
process analysis system meets the demands of FDA 21 CFR Part 11:
Electronic Signature
Access to the device functions is regulated and limited by individually adjust-
able codes – “Passcodes“. This prevents unauthorized modification of device
settings or manipulation of the measurement results. Appropriate use of these
passcodes makes them suitable as electronic signature.
Audit Trail Log
Every change of device settings can be automatically recorded and doc-
umented in the Audit Trail Log on the Protos card. The recording can be
encrypted.
Conformity with FDA 21 CFR Part 11
The module is used to measure oxygen in liquids and gases using an optical
sensor of the SE 740 series. The module permits simultaneous measurement
of oxygen partial pressure, barometric pressure and temperature. In addition,
oxygen saturation or concentration and volume concentration in gases can be
calculated and displayed.
The LDO 3400-170 module is not intended for operation in locations subject to
explosion hazards.

7
Safety Information
NOTICE!
Never try to open the module!
If a repair should be required, return the module to our factory.
If the specifications in the instruction manual are not sufficient for assessing
the safety of operation, please contact the manufacturer to make sure that your
intended application is possible and safe.
Be sure to observe during installation:
• Switch off power supply before replacing or inserting a module.
• Protect the signal inputs of the modules against electrostatic discharge.
• Before commissioning it must be proved that the device may be connected
with other equipment.

8
Software Version
LDO 3400-170 Module
Protos 3400 Device Software
The LDO 3400-170 module is supported by software version A.0 or higher.
LDO 3400-170 Module Software
Software version 1.x
Menu Display Device description
Device hardware and software
version
Provides information on all modules
installed: Module type and function,
serial number, hardware and software
version, and device options.
Select the different modules (FRONT,
BASE, slots 1 - 3) using the arrow keys.
Device description
Return
22.7 °C
83.3 %Air
Operating panel Protos
Module FRONT 3400-011
Hardware: 1.1, Software: A.1
Serial number: 08150815
BASE
Module FRONT
Querying the Device/Module Software Version
When the analyzer is in measuring mode:
Press menu key, open Diagnostics menu: Device description
Sensor
Device description
Return
22.7 °C
83.3 %Air
Digital sensors
Module LDO 3400-170
Hardware: 1, Software: 1.0
Serial number: 471101149
BASE
FRONT
Sensor
Querying the module software
version
LDO 3400-170 module
hardware and software version,
serial number – here installed in
slot3.
Module

9
Modular Concept
Basic Unit, Measuring Module, Additional Functions.
Documentation
The basic unit is accompanied by a CD-ROM containing the complete
documentation.
Latest product information as well as user manuals for earlier software releases
are available at www.knick.de.
Protos 3400 is an expandable modular process analysis system.
The basic unit (FRONT and BASE modules) provides three slots which can be
equipped by the user with any combination of measuring or communication
modules. The software capabilities can be expanded by additional functions
(options). Additional functions must be ordered separately. They are supplied
with a device-specific TAN for function release.
3 module slots
for free combination of
measuring and communication
modules
Measuring Modules
• pH / ORP / Temp
• O2/Temperature
• Noncontacting conductivity / Temp
• Contacting conductivity / Temp
• Memosens sensors
Additional Functions
Activation via
device-specific TAN
Protos card
Data recording
ProgaLog 3000
Windows® software for
parameter setting and
data evaluation
Protos 3400(X) Modular Process Analysis System
Communication modules
• OUT (additional switching and current
outputs)
• PID (analog and digital controller)
• Profibus PA
• Foundation Fieldbus
• FIU (radio, Memosens, Unical)
(software occupies 2 slots)
• Unical probe controller

10
Short Description
Short Description: FRONT Module
Transflective LC graphic display
(240 x 160 pixels)
white backlighting, high resolution
and high contrast.
4 captive screws
for opening the analyzer
(NOTICE! Make sure that the gasket between FRONT and
BASE is properly seated and clean!)
%Air
°C
24.0°C 25.8°C
Red LED
signals failure (On) or maintenance
request/function check (blinking)
according to NE 44.
Green LED
Voltage supply okay
5 self-sealing cable glands
M20 x 1.5
for entry of voltage supply and signal lines
2 softkeys
with context-sensitive functions.
User interface
with plaintext menus as recom-
mended by NAMUR.
Menu texts can be switched to:
German, English, French, Italian,
Swedish/Portuguese, or Spanish.
Intuitively acquirable menu logic,
based on Windows standards.
Control panel
3 function keys
(menu, meas, enter)
and 4 arrow keys for menu selection
and data entries
Measurement display
Secondary displays
Tabla de contenidos
Otros manuales de Unidad de control de Knick

Knick
Knick Protos Compa 3400(X)-081 Manual de usuario

Knick
Knick Protos 3400 Series Manual de usuario

Knick
Knick Protos COMFF 3400-085 Manual de usuario

Knick
Knick Protos OXY 3400-067 Manual de usuario

Knick
Knick Protos LDO 4400-170 Manual de usuario

Knick
Knick Protos II 4400 Manual de usuario

Knick
Knick Protos MS 3400-160 Manual de usuario
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario