INSTALLALTION & MAINTENANCE MANUAL
Hardware Needed
Y
ou will need the following hardware:
-Adequate gauge & length of wire for your application
-Proper size fuses or breakers to handle amperage
-Proper wire connectors for your application
-Fasteners appropriate size to mount herater.
In certainapplications,conduitmayberequiredbycode. Check
local electrical codes. If you want to be able to turn the heater,
be sure to use flexible conduit.
Mounting Height
Whentheairflowoftheheaterisdirectedverticallyorhorizontally,
theminimum mountingheight is6feet inUSA and8 feetinCanada.
MountingheightsdependuponbuildingutilizationandheaterKW
capacity.
Unpack & Inspect Your New Heater
Location of Heater
The heater should be installed out of the reach of persons. The
direction of air flow should not be restricted by machinery, beams,
etc., and the air flow should wipe exposed walls, rather than
blowing directly at them. When more than one heater is used in an
area, the heaters should be arranged so that the air discharge of
each heater supports the air flow of the others to provide best
circulation of warm air. (See Air Flow Chart)
WARNING
Model: KBP2406 is 240 volt. It is important that you
verify the power supply voltage is the same as the
nameplatevoltageoftheheater. Improper installation
or failure to follow the procedures as outlined in this
manualcan result indamage to theheater. Notethat
theKBP2406 willoperate at 208 volt but will produce
25% less wattage and draw 13% less amps. Dis-
connectall power fromthe heater at themain service
panel before attempting to install or service this unit.
All electrical wiring must conform to local electrical
codes. Heater circuit must be properly protected.
Remove the heater from the box and inspect it for any damage.
Verify that you have received the mounting bracket and
accesories.
Tools Needed
You will need the following tools to install your unit heater:
Screwdriver-(Phillips&Slotted),WireCutters,Pliers,Adjustable
Wrench, Electric Drill
Locate a stud in ceiling or wall and securely fasten bracket with a
minimum of two #12 fasteners 1-1/4" long. Attach heater to bracket
with 3/8" x 1" wing nut & lock washer supplied. Install the lock
washer between the bracket and heater, do not put lock washer
on the plastic wing nut. After desired air discharge position has
been determined, tighten wing nut so that heater will not pivot.
Mounting Heater
Distance From Walls
Maintain 6" minimum clearance to side walls and 2" to ceiling in
back of the heater (Air Intake Side). Maintain 18" clearance in
front of the heater (Dischage Side.)
Model: KBP2406 240V-1phase Unit Heater
kbp2406.pm65rev02/03