Kentec Electronics DNX-R-2F-K Manual de usuario

*Man-1492*
Intelligent Network Solutions
DNX-R-2F/FC-K
Hybrid/RS485 and Full Optic Fibre Intelligent Network Analyser
User Manual
Man-1492
DNX-R-2F/FC-K
Rev.02

Legal information
The contents of this document are provided “as is”, except as required by applicable law, no
warranties of any kind, either express or implied, including, but not limited to, the implied
warranties of merchantability and fitness for a particular purpose, are made in relation to the
accuracy and reliability or contents of this document. Kentec reserves the right to revise this
document or withdraw it at any time without prior notice.
Under no circumstances shall Kentec be responsible for any loss of data or income or any
special, incidental, and consequential or indirect damages howsoever caused.
More information about Kentec can be found at the following Internet address:
http://www.kentec.co.uk
Man-1492
DNX-R-2F/FC-K

Safety
Prior to installation:
Read this manual completely and gather all information on the unit.
Ensure that your application does not exceed the safe operating specifications for this
unit.
This unit should only be installed by qualified personnel.
This unit should be built into an apparatus cabinet, or similar, where access is
restricted to service personnel only.
The power supply wiring must be sufficiently fused, and if necessary, it must be
possible to disconnect manually from the power supply. Ensure compliance to national
installation regulations.
This unit uses convection cooling. Avoid obstructing the airflow around the unit.
Before mounting, using or removing this unit:
Prevent access to hazardous voltages by disconnecting the unit from the power supply.
Warning! Do not open a connected unit. Hazardous voltages may occur within this unit
when connected to a power supply.
Care recommendations
Follow the care recommendations below to maintain full operation of the unit and to
fulfil the warranty obligations.
This unit must not be operated with the cover removed.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit. Rough handling beyond the specification may
cause damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages etc). The unit is not
waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas. Connectors as well as other
mechanical parts may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Kentec
distributor office, or Kentec Tech support.
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
Man-1492
DNX-R-2F/FC-K

Agency approvals and standards compliance
Type
Approval / Compliance
EMC
EN 61000-6-2, Immunity Standard (Industrial Environments)
EN 61000-6-4, Emission Standard (Industrial Environments)
Safety
EN 60950, IT Equipment
Table 1
Ratings
Power
18 to 36V (24V DC nominal); 170mA (at 24V)
Temperature (Operating)
-10 to 70°C
Temperature (Storage)
-40 to 70°C
Ingress protection (IP)
IP20
Table 2
4
Man-1492
DNX-R-2F/FC-K

Safety Control Drawing
Position
Description
Input / Output values
1
RX –LC connector interface for fibre - PORT B
Data rate: 100 Mb/s –125 MBd.
Fibre drive distance:
M: Multi-mode - up to 2km
S: Single-mode –10 / 15 / 20 /
40 / 80km variants
M: 850nm / 1310nm
S: 1310 / 1550nm
BiDi: 1310 & 1550nm
2
TX –LC connector interface for fibre - PORT B
3
RX –LC connector interface for fibre - PORT C
4
TX –LC connector interface for fibre - PORT C
5
Screen/Shield RS-485/ARCNET - PORT B or C
Umax = ± 5Vpk
Imax = ± 60 mA
Data rate:
4.8 to 115.2 kbit/s
6
In / Out / + line RS-485/ARCNET - PORT B or C
7
In / Out / - line RS-485/ARCNET - PORT B or C
8
Screen/Shield RS-485/ARCNET - PORT A1 (Panel IN Port)
9
In / Out / + line RS-485/ARCNET - PORT A1 (Panel IN Port)
10
In / Out / - line RS-485/ARCNET - PORT A1 (Panel IN Port)
11
Screen/Shield RS-485/ARCNET - PORT A2 (Panel OUT Port)
12
In / Out / + line RS-485/ARCNET - PORT A2 (Panel OUT Port)
13
In / Out / - line RS-485/ARCNET - PORT A2 (Panel OUT Port)
Table 3
DNX R-2F Configuration DNX R-2FC Configuration
Figure 1
Table 4
Position
Description
Input / Output values
1
In / +Voltage A
Uin = (18 –36): 24 VDC Nominal
Iin = 210 mA Rated at 24 VDC
2
In / Common
3
In / +Voltage B
4
In / Common
5
Earth connection
6
In & out / Relay contact (C - Common)
Uin = 30 VDC max
Iin = 2000 mA max, Pin = 60 W max
7
In & out / Relay contact (NC - Normally Closed)
8
In / Out / - line RS-485 –IO Interface
Umax = ± 5Vpk
Imax = ± 60 mA
Data rate:
4.8 to 115.2 kbit/s
9
In / Out / + line RS-485 –IO Interface
10
Screen/Shield RS-485 –IO Interface
5
Man-1492
DNX-R-2F/FC-K

Functional description
The DNX R-2F/FC are network nodes that support intelligent infrastructure monitoring
of the hybrid and Optic Fibre network bus with RS-485 / ARCNET CIE interface ports
A1 and A2.
Figure 2: Design Structure Diagram
The DNX R-2F/FC can function in one of two modes:
1) Mode 1 as a PASSIVE dual port Optic Fibre / RS-485 medium converter.
2) Mode 2 as an ACTIVE network node in either a class A or class B monitored
network. (ACTIVE mode is required for use as a network analysis tool)
The mode can be selected through Set 6, switch 4 in Figure 6 and Table 10.
Note* The DNX R-2F/FC will operate in a basic mode unless upgraded to unlock
the additional features offered by the firmware upgrade (DNX R-2F/FC-UG).
Refer to Table 9a for the features included in the DNX R-2F/FC and DNX R-2F/FC-
UG products.
The DNX R-2F/FC may be purchased and later upgraded with the
DNX R-2F/FC-UG functionality by purchasing a license key that allows the IVIEW
application tool to unlock the additional functionality. The DNX R-2F/FC will
operate in BOTH PASSIVE and ACTIVE Modes, with the DNX R-2F/FC-UG
increasing the features set.
6
Man-1492
DNX-R-2F/FC-K

The additional features offered with the DNX R-2F/FC-UG license are accessed by
using the IVIEW application. The license indication LED I/O 3 on the keypad is used to
indicate a licensed/unlicensed state, as in Figure 20.
The DNX R-2F/FC can operate in a mode with two optic fibre interfaces (2F) located on
ports B and C and also in a mode with a single optic fibre interface and an RS-485
interface (FC or CF).
In hybrid mode (FC /CF) the optic fibre interface on the DNX R-2F/FC can be
configured as either port B or C by selecting the correct rotary switch setting as per
Table 11. When used to support an optic fibre link in a class A bus configuration, one
of the
DNX R-2FC modules would require a port swap to support the standard port B to C
connection format around the closed ring. An example of this is illustrated in Figure 3.
Figure 3: Class A –Hybrid Redundant Network
7
Man-1492
DNX-R-2F/FC-K

When using as a 2F module, the two Optic Fibre ports (B & C) are connected as per
Figure 18a.
Depending on the driver module selected, the Optic Fibre, transceiver modules can
support transmission distances up to 80 km. The CIE connection to port A1 and/or A2
is via an RS-485 or ARCNET interface. The connection to ports A1, A2, B and C are as
indicated in Figures 18a and 18b, depending on the mode of operation.
The different operational configurations are presented in figures 4a, 4b, 4c and 4d.
Figure 4a: ACTIVE or PASSIVE Mode (Class B) –DNX R-2F/FC Independent Medium Converters
Figure 4b: ACTIVE Mode (Class A) –DNX R-2F/FC Redundant Radial Link
8
Man-1492
DNX-R-2F/FC-K

Figure 4c: ACTIVE or PASSIVE Mode –DNX R-2F/FC Class A Redundant Hybrid Network
Figure 4d: ACTIVE or PASSIVE Mode –DNX R-2F/FC Class B Radial Hybrid Network
*Note –The Class A or B mode of operation is applicable to both ACTIVE and
PASSIVE Mode.
9
Man-1492
DNX-R-2F/FC-K

Figure 4e: DNX R-2F/FC Port A1 and A2 Connections
The module supports 2-wire half duplex communication from CIE nodes
(RS-485 / ARCNET). With the DNX R-2F/FC-UGupgrade, the module dynamically
manages and protects the data bus through monitoring the data it routes. The
modules are transparent to the CIE protocols, only routing and analysing the data
structure but not the content. The maximum standard transmission rate supported on
the CIE ports (A1 and A2) is 115.2 kbit/s for RS-485 and 312 kbits/s for ARCNET.
(Higher transmission rates are possible with OEM support).
10
Man-1492
DNX-R-2F/FC-K
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Instrumento de medición de Kentec Electronics
Manuales populares de Instrumento de medición de otras marcas

Endress+Hauser
Endress+Hauser Proline Promag 50 Especificaciones técnicas

Siemens
Siemens SITRANS F Coriolis FCT030 Manual de lista de piezas

KLINGER
KLINGER CMF V Series Manual de usuario

EXFO
EXFO FTB-2 Manual de operación y mantenimiento

Keysight
Keysight M8290A Manual de usuario

ADTEK
ADTEK MW-5 Manual de usuario