KEBCO COMBICOM Manual de usuario

COMBICOM
GB Installation Manual USB Serial Converter
Translation of Original Manual
Document Part Version Date
20094859 GBR 00 1014


D - 3
Table of Contents
Table of Contents
1. Introduction..................................................................................................... 4
1.1 General .................................................................................................................................4
1.2 Validity ..................................................................................................................................4
1.3 Qualication .........................................................................................................................5
1.4 Order data.............................................................................................................................5
1.5 Product description.............................................................................................................5
2. Hardware ......................................................................................................... 6
2.1 Description of USB serial converter ..................................................................................6
2.2 Technical data ......................................................................................................................6
3. Software .......................................................................................................... 7
3.1 Manual Driver Installation ...................................................................................................8
3.2 Use among Combivis 5.6 ....................................................................................................8
Listofgures
Figure 1: USB serial converter .................................................................................................6
Figure 2: Conguration.............................................................................................................9

GB -4
Introduction
1. Introduction
1.1 General
Prior to performing any work on the unit the user must familiarize himself with the unit. This
includes especially the knowledge and observance of the safety and warning directions.
The pictographs used in this instruction manual have following meaning:
Danger Refers to danger of life by electric current.
Warning Refers to possible danger of injury or life.
Note Refers to tips and additional information.
1.2 Validity
This manual as well as the specied hardware and software are developments of the Karl E.
Brinkmann GmbH. Errors and omissions excepted!The company Karl E. Brinkmann GmbH
established this documentation to the best of her knowledge but without engagement, that
the herein stated specications may not provide the user with the expected advantagesThe
Karl E. Brinkmann GmbH reserves the right to change specications without prior notice or
to instruct third persons.
The information contained in the technical documentation, as well as any user-specic advice
in spoken and written and through tests, are made to best of our knowledge and information
about the application. However, they are considered for information only without responsibil-
ity. This also applies to any violation of industrial property rights of a third-party.
Inspection of our units in view of their suitability for the intended use must be done generally
by the user. Inspections are particularly necessary, if changes are executed, which serve for
the further development or adaption of our products to the applications (hardware, software
or download lists). Inspections must be repeated completely, even if only parts of hardware,
software or download lists are modied.
Controlling by the
user
Application and use of our units in the target products is
outside of our control and therefore lies exclusively in the
area of responsibility of the user.

GB -5
Introduction
Use under spe-
cial conditions
The used semiconductors and components of KEB are de-
veloped and dimensioned for the use in industrial products. If
the KEB COMBIVERT is used in machines, which work under
exceptional conditions or if essential functions, life-supporting
measures or an extraordinary safety step must be fullled,
the necessary reliability and security must be ensured by the
machine builder.
1.3 Qualication
All work from the transport, to installation and start-up as well as maintenance may only be
done by qualied personnel (IEC 364 and/or CENELEC HD 384 and IEC-Report 664 and note
national safety regulations). According to this manual qualied staff means those who are able
to recognise and judge the possible dangers based on their technical training and experience
and those with knowledge of the relevant standards and who are familiar with the eld of pow-
er transmission (VDE 0100, VDE 0160 (EN 50178), VDE 0113 (EN 60204) as well as those
who note the valid local regulations).
Danger by
high voltage
KEB electronics components contain dangerous voltages
which can cause death or serious injury. In operation, drive
converters, depending on their degree of protection, may have
live, uninsulated, and possibly also moving and hot surfaces.
Care should be taken to ensure correct and safe operation to
minimise risk to personnel and equipment.
1.4 Order data
USB serial Converter 00F58060-0040
USB cable type A type B, 3 m (included) 00F50C4-1030
Adapter DSUB9 to RJ45 00F50C0-0020
1.5 Product description
The USB serial converter is used for the connection of KEB inverters, operators or controls
with DIN66019 interface or interface HSP5 at the USB port of personal computers. It repre-
sents a virtual COM interface on PC side.
The USB serial converter is not a standard USB serial converter. It can be used exclusively
for the communication with KEB units with the interfaces specied above.The converter must
be plugged directly on the interface. A 0.2 m, 1:1 cable can be used as extension. Use adapt-
er DSUB9 to RJ45 (.00F50C0.-0020) to connect the HSP5 interface by RJ45 socket.

GB -6
Hardware
2. Hardware
2.1 Description of USB serial converter
The serial side supports:
DIN66019 (RS 232)/HSP5 (TTL level)
USB socket type B
Figure 1: USB serial converter
2.2 Technical data
General
Dimension (H x B x L) 20 mm x 35 mm x 88 mm
Weight 30 g
Ambient conditions during operation -10°…45°C
Ambient conditions at storage -25°…70°C
Climatic category (EN60721-3-3) 3 K 3
Note Voltage supply via interface
Others Internal potential isolation

GB -7
Software
3. Software
The serial side supports:
• DIN66019 (RS 232)
• HSP5 (TTL level )
The type of interface is automatically detected.
If the DIN66019 protocol is used on the serial side, the "DIN66019 protocol USB" is only
physically converted to "DIN66019 protocol RS232" in the USB serial converter and the log
data remains unchanged.
If the HSP5 protocol is used on the serial side, the "DIN66019 protocol USB" is converted to
"HSP5 protocol TTL level" in the USB serial converter.
The following KEB services are supported (see protocol description HSP5):
0Read / write the parameter value (extended set-addressing)
1Read / write the parameter value (default set-addressing)
18 Read process data telegram type 3 (Timestamp, 2x32, 2x16 Bit)
No automatic baud rate search is supported. The baud rate is adjusted via the used program
e. g. The baud rate can be adjusted in the range of 2400Baud…115.2 kBaud.
The default value of 38.4 HSP5 kBaud should not be changed.
At DIN66019 on F5 the value of 9.6 kBaud should be used.
The baud rate of the connected unit (see unit parameter) and the driver setting for
the used COM port must be adjusted equal.

GB -8
Software
3.1 Manual Driver Installation
1.
The *.inf-le must be assigned once to the system on the PC.
The installation must be made separately for each USB port.
2. The assistent for new hardware opens automatically, if the converter is connected to
a not yet congured for USB serial converter.
3.
The USB-inf-le is located in a „USB driver package“. The „USB driver package“ can
be downloaded under www.keb.de -> Download -> Search for: „USB driver pack-
age“. Extract the “USB driver package” les after the download.
4. Set the path in which the "kebcdc.inf" and kebcdc.cat les are found.
5. Finish the installation.
Computers with Windows 7 do not ask for a driver because a ST Electronic driver
is automatically installed by the system. The function is given, but is recognized
as USB converter, not as KEB unit.If required it can be replaced manually.
With the KEB-USB converter the parameter les can not be read-out with COM-
BIVIS 5 from the F5 when connected via HSP5.
3.2 Use among Combivis 5.6
When using the USB serial converter KEB under COMBIVIS 5.6 some things to consider:
The communication settings are run in serial protocol DIN 66019, even if the converter is con-
nected to an interface of a HSP5 COMBIVERT F5 or COMBIVERT B6. The protocol HSP5 is
always converted to DIN 66019.
The RTS delay must be set between 3000ms and 5000ms. By the delay transmission of the
data is somewhat slowed, whereby the converter has sufcient time to process the data.

GB -9
Software
The conguration settings in COMBIVIS 5.6 can be reached under the menu bar Edit -> Con-
guration -> DIN 66019.
Figure 2: Conguration
In the menu item "Send single" remove the tick.
The driver has to install manually, see chapter "Manual Driver Installation".Excep-
tion:The driver has already been installed automatically by COMBIVIS 6.
The COM port used by the USB converter must be entered. Located at Windows Control
Panel under Device Manager –> Ports (COM und LPT).Interface numbers can be selected
from 0 to 9. If the detected interface has a higher number, it must be renamed in the Device
Manager.
Only one USB converter can be used per PC.

GB - 10
Notes
Otros manuales para COMBICOM
3
Tabla de contenidos
Otros manuales de Convertidor de medios de KEBCO

KEBCO
KEBCO COMBIVERT F5 Manual de usuario

KEBCO
KEBCO COMBITRON 91 Manual de usuario

KEBCO
KEBCO COMBIVERT F5 Manual de usuario

KEBCO
KEBCO combivert B6 Manual de usuario

KEBCO
KEBCO COMBIVERT F5 Manual de usuario

KEBCO
KEBCO COMBIVERT F5 Manual de usuario

KEBCO
KEBCO COMBIVERT T6APD Manual de usuario

KEBCO
KEBCO COMBIVERT S6 Series Manual de usuario

KEBCO
KEBCO COMBIVERT F6 Manual de usuario

KEBCO
KEBCO COMBIVERT 2M.F5.K8F-6009 Manual de usuario