Katadyn Spectra Watermakers Catalina 340R Manual de usuario

Catalina 340R - Remote Manual
Installation and Operating Manual
Spectra Watermakers
Katadyn Desalinaon LLC.
2220 S. McDowell Blvd Ext. Petaluma, CA 94954
Phone: 415-526-2780 Fax: 415-526-2787
info@spectrawatermakers.com
www.spectrawatermakers.com
Updated February 2021

2

3
Spectra Product Registraon Form
(To be completed by end user/owner)
hps://spectrawarranty.formstack.com/forms/product_registraon
Spectra Watermakers Commissioning Report
(To be completed by authorized installer)
hps://spectrawarranty.formstack.com/forms/spectra_install_commissioning_report
Note: Oer & warranty criteria eecve 1/1/2021. For purchases made in the EU, please see ‘Expanded Warranty’
secon of warranty policy in back of the manual for EU specic coverage.
EXCITING EXTENDED WARRANTY OFFER!
-Upgrade the standard 1-YEAR manufacturer warranty to 2-YEARS and LIFETIME on Clark Pump.
Follow the below steps to submit for approval:
1. Have system installed & commissioned by Spectra Authorized FSP (full-service provider)
2. Fill out web-based Product Registraon form (see back of owner’s manual for paper copy)
3. Complete web-based install/commissioning form (see back of owner’s manual for paper copy)
4. Upon sasfactory review of required submissions, your 4-digit system serial number will
receive an extra year of warranty coverage, and lifeme coverage on the Clark Pump!
See ‘Extended Warranty’ secon of owner’s manual for full coverage details.

4

5
Thank you for your purchase of a Spectra Catalina 340R system. When properly installed and
maintained, it will provide years of trouble-free service. Professional installaon is strongly
recommended. Like any piece of mechanical equipment, the system will require inspecon
and service, so plan ahead for service access and install “service loops” in cabling. If a dealer is
installing the system for you, review the locaon of the components to ensure the installaon
will meet your approval upon compleon.
Catalina Installaon Quick Start
Important Details for Installer
1. The system must have a dedicated sea water inlet to guarantee a constant ow of water to
the system. The inlet should be as low in the boat as possible with a dedicated, forward-facing
scoop-type thru-hull ng.
2. Both the Catalina 340R feed pump module and the Clark Pump/Membrane module must be
installed in a well venlated compartment where temperatures will not exceed 113°F (45°C).
Many engine compartments exceed this temperature when underway. Warranty will be void if
the installaon does not meet this requirement.
3. Follow the wire gauge charts in the instrucons! Using larger wire than specied is
acceptable.
4. If you are separang the Clark Pump/membrane assembly, please review the high pressure
tube assembly instrucons. Improper assembly will cause failure!
5. Run, test, then sea trial the complete system before assuming it is operaonal. If the boat is
in fresh or dirty water, see Dry Tesng the System. Aer tesng, make sure the ush cycle
operates properly. The water going overboard at the end of the ush should measure <1000
PPM Total Dissolved Solids.
6. The Spectra Remote Manual control must have DC power connuously to achieve the full
benets of the fresh water ush system. The domesc fresh water pressure must be on and
the fresh water tank level maintained. Calculate about 7 gallons (27 liters) per ush.
7. The Spectra Remote Manual must be de-powered (DC power o) aer the system is pickled
or winterized.
8. Spectra dealers are responsible for educang the vessel owners on the operaon and
maintenance of the system. Please walk through the enre installaon with our customer.
9. The equipment owner should ll out the warranty card or register online.

6

7
Table of Contents
Geng Started .................................................................................................................... 9
Installaon Basics.............................................................................................................. 10
Components ...................................................................................................................... 11
Catalina Plumbing Schemac & Plumbing Detail..............................................................13
Product Water Plumbing and Pressure Gauge Tube Installaon ..................................... 15
Plumbing Detail ................................................................................................................. 18
Tube Fing Assembly Procedures....................................................................................20
Electrical ............................................................................................................................ 22
Installing A Remote Controller..........................................................................................25
Oponal Tank Switch Installaon ..................................................................................... 26
Operaon ...........................................................................................................................
New Systems Start Up and Tesng ...................................................................................28
Dry Tesng with an Arcial Ocean..................................................................................29
Spectra Remote Manual Controller Guide........................................................................30
Freshwater Flush Calibraon ............................................................................................ 31
Adjusng Fresh Water Flush Duraon ..............................................................................32
Normal Operaon and Fresh Water Flush........................................................................ 33
Nominal Operang Parameters ........................................................................................33
Maintenance, Storage, and Troubleshoong ..........................................................
Maintenance .....................................................................................................................34
Introducon to Spectra Chemicals....................................................................................38
Storage Procedures ...........................................................................................................39
Winterizing with Propylene Glycol....................................................................................40
Membrane Cleaning Procedure ........................................................................................ 41
Suggested Spares...............................................................................................................42
Troubleshoong ................................................................................................................ 43
Catalina Flow Test .............................................................................................................46
Poor Water Quality............................................................................................................ 48
Technical Bullens............................................................................................................. 49
Spectra Remote Manual Controls...............................................................................
Wiring Schemac...............................................................................................................53
Control Box Wiring ............................................................................................................ 54
Exploded Views and Part Numbers........................................................................ 56
Owner Resources.............................................................................................................
Warranty, Product Registraon, Installaon & Commissioning Reports.........................65

8

9
Unpack the system and inspect it for damage during shipping. Freight damage must be
reported to the carrier within 24 hours.
Refer to the shipping list for your system to ensure you received all of the components listed.
Do not discard any packaging unl you have found and idened all of the parts. The small
installaon parts are listed on the kit list.
Study the system layout diagram, component photos, and descripons before beginning
installaon.
Lay out the system. Before starng the installaon idenfy where each module and
component will be placed. Ensure that there is enough clearance around the components for
removal of lters and system service. Make sure you have adequate tubing and hose before
starng. Addional parts may be ordered.
Getting Started
Catalina 340R Shipping List:
•Catalina Feed Pump Module
•10% Clark Pump and Reverse Osmosis Membrane Module
•Boost Pump and Sea Strainer Module
•Fresh Water Flush Module or Oponal Z-Ion Upgrade
•Service Kit
•Remote Manual Controller
•3/4-inch Black Spiral Sucon Hose (25 feet)
•5/8-inch Vinyl Hose (25 feet)
•3/4-inch Vinyl Hose (10 feet)
•1/2-inch Vinyl Hose (25 feet) ed with Quick Connect Fing on
one end, and John Guest stem ng on the other end.
•1/4-inch Black Product Tubing (25’)
We will not be held responsible for shortages that are not reported
within thirty days of the ship date.
WARNING!

10
Thru-hull Location: The system must be connected to a dedicated 1/2” to 3/4” forward facing
scoop-type intake thru-hull and seacock.
Install the thru-hull intake as far below the waterline and as close to centerline as possible to
avoid contamination and air entering the system. Do not install the intake close to, or
downstream of, a head discharge, behind the keel, stabilizer fins, or other underwater fixtures.
Thru-hulls in the bow area are susceptible to air intake in rough conditions. Sharing a thru-hull
can introduce unforeseen problems such as intermittent flow restrictions, air bubbles,
contaminants, and will void the warranty. For racing boats and high speed boats traveling above
15 knots, a retractable snorkel-type thru-hull fitting is preferred because it picks up water away
from the hull.
The brine discharge thru-hull should be mounted above the waterline, along or just above the
boot stripe, to minimize water lift and back pressure.
Double clamp all hose connections below the waterline.
Avoid restrictions or long runs on the entire inlet side of the plumbing from the thru-hull to the
feed pump module.
Secure the piping away from moving objects such as engine belts and hatches. Prevent chafe on
the tubing as required. Test and inspect all piping and hose clamps after several hours of
operation.
Pipe Fitting Instructions: To seal plastic-to-plastic fittings, wrap 6 to 8 layers of Teflon tape
over their threads. Hold the fitting in your left hand and tightly wrap the threads clockwise. For
smoother assembly, do not tape the first (starting) threads.
Wiring
• Pay attention to wire size or system performance will be impaired
• Perform wiring to UL, ABYC, CE or applicable standards
• Avoid tight hose bends and excessive runs.
• Use heavy gauge wire.
• Install feed pump module as low as possible.
• Use a dedicated thru-hull with scoop type
strainer.
Important Installation Notes
Seawater Flow
Thru-hull
Not Supplied.
Installation Basics
Avoid getting dirt or debris into the piping or hoses during assembly. A
small bit of debris can stop the system!
CAUTION!
Tabla de contenidos
Otros manuales de Sistema de agua de Katadyn
Manuales populares de Sistema de agua de otras marcas

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manual de usuario

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manual de usuario

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manual de usuario

Microline
Microline T.F.C.-4 Manual

Eureka Forbes
Eureka Forbes Aquaguard Select Manual de usuario

Cetetherm
Cetetherm AquaEfficiency Manual de usuario