Kantech ioProx P700WLS Manual de usuario

DN1628-0806
P700WLS ioProx Receiver
Installation Manual

DN1628-0806
Warning! This manual contains information on limitations regarding product use and function and
information on the limitations as to liability of the manufacturer. The entire manual should be carefully
read.
© 2008 Tyco International Ltd. and its Respective Companies. All Rights Reserved.
All specifications were current as of publication date and are subject to change without notice.
Tel: +1(450) 444-2030 • Toll Free: US & Canada: +1 888 222-1560 • Fax: +1(450) 444-2029
www.kantech.com

Installation Manual P700WLS ioProx Receiver
DN1628-0806
Table of Contents
System Overview .......................................................................................................1
Inventory 1
Technical Specifications...........................................................................................2
Installing the P700WLS ioProx Receiver.................................................................3
Global Coverage ....................................................................................................................... 3
Power Supply and Grounding.................................................................................................. 3
Recommended Wiring Distance at 12 Vdc.............................................................................. 3
Data Path Selector Settings.....................................................................................................4
Receiver Terminal Block Location........................................................................................... 4
S1 Receiver Configuration.......................................................................................................5
Receiver Wiring Diagrams........................................................................................................6
Testing the Receivers............................................................................................................... 7
PCB LED Indicators............................................................................................................................................7
Receiver Relay....................................................................................................................................................8
Receiver Mounting Location.................................................................................................... 8
Testing the Transmitters...........................................................................................9
Operating Instructions.............................................................................................................. 9
Troubleshooting.........................................................................................................9
Replacing the Transmitter Battery........................................................................................... 9

Installation Manual P700WLS ioProx Receiver
DN1628-0806

Installation Manual P700WLS ioProx Receiver
DN1628-0806 1
System Overview
The P700WLS ioProx receiver unit is designed to interface with an access control panel card reader
port using the Wiegand protocol or the Kantech eXtended Secure Format (XSF). The ioProx receiver
can read from a distance of up to 45.72 m. (150 ft.) with a power dipole antenna or 30.48 m. (100 ft.)
with a standard antenna.
The ioProx transmitters come in two versions: with 2 or 4 buttons. And each can come with or without
an integrated ioProx key tag. The receiver unit receives the ID credentials from transmitters which
consist of a site code and ID number. For increased security, the ioProx transmitter uses incremental
packet transmission so that a different transmission code is created every time the button is pressed;
Transmitters with integrated ioProx key tag also permit access to users when both ioProx receivers
and card readers are installed in different areas of the same building.
The receiver jumpers can be configured to determine which button on the key tag transmitter will
activate the receiver. The same transmitter can be programmed to operate up to four different
receivers (one per button) located within close proximity to each other (and to operate more receivers
that are located farther apart.) The transmitter ID will only be sent to the access controller when a valid
button is pressed.
Inventory
The P700WLS ioProx receiver unit provides a reliable long-range wireless access control from a gate
or an overhead door. Each unit is packed with:
1 P-WLS-A1 whip antenna
4 enclosure fastening screws
Mounting hardware is not provided.

Installation Manual P700WLS ioProx Receiver
DN1628-0806
2
Technical Specifications
P700WLS ioProx Receiver P72WLS/P74WLS Transmitters
Power: 12-24 VDC Power:
CR2032 3V lithium battery,
included (3 year average
lifetime)
Current: 50mA (stand-by) 100mA
(peak) Operating temperature: 0°C to 70°C (32°F to 158°F)
Output: XSF or 26-bit Wiegand
selectable Dimensions (HWD) cm: 7.30 x 3.81 x 1.59
Operating temperature: -30°C to 68°C
(-22°F to 155°F) Dimensions (HWD) in: 2.88 x 1.50 x 0.63
Dimensions (HWD) cm: 19.21 x 13.02 x 4.14 Certification: FCC
Dimensions (HWD) in: 7.56 x 5.13 x 1.63 P-WLS-A1 Standard Whip Antenna
Enclosure material:
Polycarbonate (HB) with UV
stabilizer, weather-resistant,
IP56, NEMA 4X rated Read range: Up to 30 m. (100 ft.)
Frequency: 433.92 MHz Note: Antenna P-WLS-A1 may be remotely installed using
coaxial cable up to 4.5 m. (15 ft.)
Cable type: 3 twisted pairs, unshielded
cable P-WLS-A2 Power Dipole Antenna
Read range: Up to 45 m. (150 ft.)
Maximum distance from
controller at 12 VDC:
152 m (500 ft) with 18 AWG
112 m (369 ft) with 20 AWG
76 m (248 ft) with 22 AWG
Note: Antenna P-WLS-A2 MUST be installed using coaxial
cable up to 4.5 m. (15 ft.), RG1 1/U (Belden ref#8213)
coaxial cable is recommended. Optional
Certification: FCC
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.

Installation Manual P700WLS ioProx Receiver
DN1628-0806 3
Installing the P700WLS ioProx Receiver
Global Coverage
When global coverage of a large area is required, there should
be a sufficient number of receivers to give overlapping
coverage of receiving patterns.
Use the SW terminals if the receiver antennas are less than
30.5 m (100 ft) apart. The SW terminal connection prevents
data clash at the control panel. (See Figure 2, Note 5 on page
6.)
Power Supply and Grounding
Power requirements: 12-24 VDC, 50mA (stand-by), 100mA (peak). A linear type power supply is
recommended if a separate power supply is used. Proper grounding gives an electrical charge, like an
electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into
the earth. It is strongly recommended to connect an earth ground wire to each receiver unit. (See
Figure 2, Note 2 and Note 4 on page 6.)
Recommended Wiring Distance at 12 Vdc
P700WLS receiver: 3 twisted pairs, unshielded cables
With #18 AWG: 152 m (500 ft)
With #20 AWG: 112 m (369 ft)
With #22 AWG: 76 m (248 ft)

Installation Manual P700WLS ioProx Receiver
DN1628-0806
4
Data Path Selector Settings
The receiver unit provides for field selectable pins JP2 located near the center of the board (Figure 1)
Receiver Terminal Block Location
The receiver terminal block is removable. (Refer Figure 1) It can be mounted vertically or horizontally.
Connect 22 to 14 AWG wires to the blue terminal block.
Figure 1 Terminal Block Location

Installation Manual P700WLS ioProx Receiver
DN1628-0806 5
S1 Receiver Configuration
Placing the DIP switches in the ON or OFF position determines which specific button on the
multi-button transmitter will activate the receiver and Wiegand format to be transmitted to the control
panel. (See Table 1 below)
Data Path Selector Settings:
Kantech XSF (default): Position 4 (ON).
26-bit Wiegand: Position 4 (OFF).
The selectors for position 1 and 2 select which of the four buttons will
activate the receiver.
Format Button 1 2 3 4
XSF Button 1 OFF OFF ON ON
Button 2 ON OFF ON ON
Button 3 OFF ON ON ON
Button 4 ON ON ON ON
26W Button 1 OFF OFF ON OFF
Button 2 ON OFF ON OFF
Button 3 OFF ON ON OFF
Button 4 ON ON ON OFF
Table 1 Data Path Selector Settings
1 2 3 4
S1
1 2 3 4
S1
B
utton
1
B
utton
3
Button 2 Button 4
1 2 3 4
S1
1 2 3 4
S1

Installation Manual P700WLS ioProx Receiver
DN1628-0806
6
Receiver Wiring Diagrams
Figure 2 Typical Installation and Two Receivers Connected to One Port Installations
Otros manuales para ioProx P700WLS
1
Tabla de contenidos
Otros manuales de Receptor de Kantech