JSB RS64 Manual de usuario

RS64
INTRUDER
ALARM
CONTROL
PANEL
USER
MANUAL
23
1
56
4
89
7
0
7702-1783 VERSION 1-17

INDEX
Introduction .................................................................................................1
The Remote Keypad................................................................................2
Operation......................................................................................................3
Full Set ...........................................................................................................3
Part Set..........................................................................................................4
Unset ...............................................................................................................4
Reset................................................................................................................5
Chime..............................................................................................................5
Zone Omit....................................................................................................6
Programming ..............................................................................................7
Setting up Codes.......................................................................................8
Setting Time and Date..........................................................................9
Chime Suite.................................................................................................9
Part Set Suites ...........................................................................................9
Testing ..........................................................................................................10
Sounder Test.............................................................................................10
Walk Test....................................................................................................10
Light Test....................................................................................................11
Remote Communication....................................................................11
Remote Reset...........................................................................................11
Miscellaneous............................................................................................12
Installer’s Specification ......................................Inside Back Cover
Note: Due to a policy of continued development of the RS64 intruder alarm
control panel, the information contained in this guide is subject to change
without notice.

1
Introduction
This guide will help you to undertand your RS64 intruder alarm control panel.
It is important to read it carefully in order to get the most from your system.
Instructions are in a step by step form with diagrams where appropriate. The RS64
has been designed to be as simple to operate as possible.
The RS64 will have been programmed by the Installation Engineer to suit your
particular installation. The system is operated from one or more Remote Keypads all
functions are processed by the main Control Unit which is accessed by the engineer
only.
RS64 has been designed to allow two different levels of access to the system. The
System Manager is the person who has overall responsibility for the system and this
means that he/she has access to more functions than the General User. To operate
your RS64 the Installation Engineer will need to provide you with at least one of two
different types of 4-digit Access Codes:
Master Access Code - used by the System Manager to operate the system and carry
out a range of programming functions:
•Set up and modify all the User Codes.
•Carry out Tests e.g. Sounders and Detectors.
•Set up a Chime Suite.
•Set up a Part Set Suite.
•Modify the Time and Date settings.
User Access Codes - individual codes that are employed by up to nine General Users
for day-to-day operation:
•Setting and Unsetting the Panel.
•Omitting Zones.
•Reset after an Alarm Activation
The System Manager also has access to the General User functions above.
To Access the Panel
Enter your 4-Digit Access Code using the numeric keys
OPEN Light will flash slowly
Proceed with Operating/Programming/Testing function

2
Function Keys and Status Lights
These keys are used to select
different operating modes and to
reset after an alarm. These Status
lights indicate System Status.
(See pages 3 to 5)
Numeric Keys and Zone Lights
These keys are used for entering
your security code to turn the
system on and off. These keys are
also used to program the
system. Eack key incorporates a
Zone/Status light.
(See pages 7 to 11)
DESCRIPTION OF SOUNDS
Keypad press - Quick blip
Entry sound - Solid tone pulsed on and
off slowly
Exit sound - Solid tone
Tamper sound - Fast Broken Tone
Alarm sound - Wailing tone
Fire sound - Two tone sound
Night Setting - Soft Clicking
Chime - Warble
Fault sound - Fast Broken Tone
Error Tone - Buzz
LIGHT INDICATORS
CONDITION ON/CONTINUOUS OFF SLOW FLASH QUICK FLASH
OPEN Unset System Set Waiting for Blue Key Chime Mode
FAULT Setting Fault Ok System Fault Activation
NO LINE Refer to Communicator Section
NO MAINS No Mains Power Ok/Set MainsRestored/Fail1Hr
TAMPER Standing Tamper Fault Ok Panel/Bell Lid Tamper Zone/RKP Tamper
ENGINEER Engineer On Site Ok Engineer Needed Service Needed
ZONES 1-10 Zone in Fault Ok Zone Omitted First To Alarm

3
Operation
False Alarms
Before using the RS64 it is important to know how to avoid false alarms. Most false
alarms are caused when setting or unsetting the system. By following these few simple
tips you should avoid any potential problems.
•Make sure that all doors to be set on the system are firmly secured and cannot
swing open accidentally.
•Ensure that any room containing detection devices is free of moving objects
such as pets or moving curtains.
•When re-entering the protected area proceed directly to the nearest Remote
Keypad without delay and do not stray from the exit/entry route.
Unset
The RS64 is alert to certain types of alarms (e.g.Tamper) at all times; when the system
is Unset it is still operating in Day Mode. Under normal circumstances you should have
the OPEN light fully ON (GREEN) and no other lights showing. In addition to the
Guard Zones which only operate when the system is set your installation may include
other Zones which operate on a 24 Hour basis (e.g. a Zone with a Panic Button).
Full Set
You will need to use Full Set when leaving the protected premises unattended.
Enter your 4-Digit Access Code. OPEN light starts flashing.
Press FULL
If system clear, Exit Tone will be heard. This is a continuous high pitched tone.
Leave via Intermediate and Final Exit zones
Close final door to set (or operate push to set button if fitted)
After 2 seconds the Exit Tone should cease.
If system is not clear, Fault Tone sounds. This is a rapid intermittent tone.
Identify which zone light is lit on keypad
Enter your 4-Digit Access Code; this will abandon the setting operation
Investigate fault and remedy if possible
If fault cannot be remedied, call engineer
If there is a Fault Tone immediately after the system is finally closed you may have
a fault in the Exit /Entry Route; if this does not clear after a few seconds you will
need to re-enter the premises investigate the fault and turn the system off using your
4-Digit Access Code.

4
Part Set
Use Part Set when certain zones (e.g. bedrooms) will be occupied. The Part Suite will
automatically omit those Zones which are to be excluded.
Enter your 4-Digit Access Code. OPEN light starts flashing.
Press PART
If system is clear, Part Set tone is heard. This is a soft Clicking sound
Those Zones which are excluded will slowly flash.
Proceed to unset zone via entry/exit route
System is set after the Part Set timer runs out
If system not clear, Fault Tone sounds
Identify which zone light is lit on keypad
Enter your 4-Digit Access Code.
Investigate fault and remedy if possible
If fault cannot be remedied, call engineer
Unset
When you re-enter the protected area you will start the Entry Timer and the Entry
Tone (a slowly broken Exit Tone) will sound. You must then proceed directly to the
nearest Remote Keypad. You will also start the Entry Timer if you use the Remote
Keypad when the system is Set.
Whenever you hear the Entry Tone:
Enter your 4-Digit Access Code.
Entry Tone stops
The system should now be Unset with the OPEN LIGHT ON.
If zone and fault lights are lit, there has been an activation
You will now need to Reset the system (see opposite)
To silence an Alarm
It is quite possible for an alarm activation to occur while you are on the premises.
The Alarm Tones are:
Fire Alternating 2-tone sound.
Intruder Wailing sound.
Tamper Loud Rapid Pips (Fault Tone)
Enter your 4-Digit Access Code.
Alarm should be silenced
The Remote Keypad lights will indicate what has happened
You will now need to Reset the system (see opposite)

5
Reset
To reset the system after an Alarm Activation
IMPORTANT NOTE. Reset authorisation depends on the nature of the Alarm
Activation detected by the panel. Some events could indicate that you must contact an
Engineer for advice; the panel records the Alarm Activation in its internal Event Log
and may then enter a Lockout Mode preventing further use until the Engineer has
been consulted.
Enter your 4-Digit Access Code. OPEN light starts flashing.
Press RESET
All lights come on, Warble Tone sounds then the lights go out
System is now reset and ready for re-use.
If system does not reset
Use Remote Reset option (see Remote Communication section(Page 11))
Chime Mode
Chime is used to give a local audible warning from the Guard Zones including Door
Contacts when the system is Unset. This is useful when the premises are occupied
and you wish to be notified if other persons have entered the building. Your
Installation Engineer may have already programmed the system to automatically turn
Chime on during the day. You can also turn Chime On and Off yourself and set which
detectors are to be included in the Chime system.
Chime On
Enter your 4-Digit Access Code. OPEN light starts flashing.
Press CHIME
The FLASHING zones are EXCLUDED from the Chime system
If other chime zones are required, press appropriate numbered keys
System automatically enters chime mode after a short time delay
The OPEN light flashes quickly when Chime Mode is ON
Chime Off
To unset chime mode
Enter your 4-Digit Access Code.
OPEN light flashes slowly
Allow the system to time out.
OPEN light should now be ON continuously.

6
Zone Omit
This is useful if you need to remove one or more Detection Zones on a temporary
basis if you unable to fully set the system. You can use Zone Omit on any zone
provided that the Installation Engineer has not programmed the Zone as Non Manually
Omittable (this may have been done because that particular Zone is a vital element of
the system ). The Zone Omit information is automatically discarded next time you
open the system.
To Omit Zones prior to setting the system.
Enter your 4-Digit Access Code. OPEN light starts flashing.
Press OMIT. The OPEN light continues to flash slowly
Press number keys for zones to be omitted. The omitted Zone lights will flash slowly.
Either
Press FULL to Full Set with omitted zones
Or
Press PART to Part Set with omitted zones
Note: When using Zone Omit followed by PART, zones which would have been
automatically omitted by the Part Set Suite (see Programming section) will have to be
manually omitted.
To use Zone Omit on Day Zones.
Enter your 4-Digit Access Code. OPEN light starts flashing.
Press OMIT. The OPEN light continues to flash slowly
Press number keys for zones to be omitted. The omitted Zone lights will flash slowly.
Press OMIT again to return to Day Mode with omitted zones.
To cancel Zone Omit on Day Zones.
Enter your 4-Digit Access Code. OPEN light starts flashing.
Press RESET
Programming
To carry out each programming function, you must first enter Menu Mode starting from
Day Mode. Once you are in Menu Mode you then enter a 2-Digit Opcode to select a
specific programming function. When that function is completed the system returns to
Menu Mode.
Menu Mode
To enter Menu Mode
Enter the 4-Digit Master Code. OPEN light start flashing
Press 00
All lights illuminate

7
You are now in Menu Mode
Enter the 2-Digit Opcode for the function you wish to program
After programming the function
Either
Program next function by entering a new Opcode
Or
Select Opcode 99 to exit Menu Mode
All lights flash, warble tone sounds
The Control Panel is now back in Day Mode.
Note: If you get the Error Tone (a short Buzz) you have entered an incorrect Opcode.
Duress Code
To enter or change 4-digit Duress Code.
(Consult with your Installation Engineer before using this option.)
Select Opcode 02
If zone lights 1-4 flash, code exists
Press OMIT to delete the code
If zone lights 1-4 constant, enter new code
Press 4 numbered keys for new code; the lights will extinguish one at a time
Press ENTER to submit the new code
If Warble sounds, code is accepted
If Buzzer sounds, code is rejected. Try again using a different 4-Digit Code.
Keyholder Code
To enter or change 4-digit Keyholder Code.
(Consult with your Installation Engineer before using this option.)
Select Opcode 03
If zone lights 1-4 flash, code exists
Press OMIT to delete the code
If zone lights 1-4 constant, enter new code
Press 4 numbered keys for new code; the lights will extinguish one at a time
Press ENTER to submit the new code
If Warble sounds, code is accepted
If Buzzer sounds, code is rejected. Try again using a different 4-Digit Code.

8
Master Code
To enter or change 4-digit Master Code.
Select Opcode 40
If zone lights 1-4 flash, code exists
Press OMIT to delete the code
If zone lights 1-4 constant, enter new code
Press 4 numbered keys for new code; the lights will extinguish one at a time
Press ENTER to submit the new code
If Warble sounds, code is accepted
If Buzzer sounds, code is rejected. Try again using a different 4-Digit Code.
User Codes
To enter or change 4-digit User Codes.
Select Opcode 41 for User Code 1
42 for User Code 2
43 for User Code 3
44 for User Code 4
45 for User Code 5
46 for User Code 6
47 for User Code 7
48 for User Code 8
49 for Cleaner Code
If zone lights 1-4 flash, code exists
Press OMIT to delete the code
If zone lights 1-4 constant, enter new code
Press 4 numbered keys for new code; the lights will extinguish one at a time
Press ENTER to submit the new code
If Warble sounds, code is accepted
If Buzzer sounds, code is rejected. Try again using a different 4-Digit Code.
Tabla de contenidos
Manuales populares de Sistema de seguridad de otras marcas

EDM
EDM Solution 6+6 Wireless-AE Manual de usuario

Highway Safety Group
Highway Safety Group EA401 Manual de usuario

Siren
Siren LED GSM Manual de usuario

Detection Systems
Detection Systems 7090i Instrucciones de montaje

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manual de usuario

Siemens
Siemens FDM273 Manual de usuario