Fridgewatch 2000 Controller Mk5
Section 3 Publication 3-59
Issue 3.2 : 05.23 Page 6 of 222
11.6. Clean Screen .........................................................................................................................42
12. Requires Configuration Password (Orange) ............................................................... 43
12.1. Hours Run and Number of Starts...........................................................................................43
12.2. Set Time and Date.................................................................................................................44
12.3. ANINs Configuration Pages 1 to 3 .........................................................................................45
12.4. System Configuration Pages 1 to 7........................................................................................46
12.5. Settings S1 to S287 Pages 1 to 38 ........................................................................................47
12.6. ALT Settings (Alarm, Limit & Trip) pages 1 to 7.....................................................................48
12.7. ALT (Alarm, Limit & Trip) Timer Settings Pages 1 to 7 ..........................................................49
13. Home Page ................................................................................................................. 50
13.1.1.Time and Date ......................................................................................................................50
13.2. Menu/Back Button..................................................................................................................51
13.3. Compressor and Refrigerant Numbers ..................................................................................51
13.4. New Alarm and Acknowledged Alarm Exists .........................................................................51
13.5. Compressor Status ................................................................................................................52
13.6. Start (Manual Start)................................................................................................................52
13.7. Oil Fill Button..........................................................................................................................52
13.8. Load and Unload (Manual Capacity Control Only).................................................................53
13.9. Controlled Stop/Stop Button RESET......................................................................................53
14. Communications ......................................................................................................... 54
14.1. RS 485 Port Parameters........................................................................................................55
14.2. Communication (Comms) ......................................................................................................55
14.2.1. Communications Example...............................................................................................56
15. Principles of Control .................................................................................................... 57
15.1. Compressor Capacity Control................................................................................................57
15.1.1. Compressor Slide Valve Position (SVP) .........................................................................57
15.1.2. Slide Valve Position Signal..............................................................................................58
15.1.3. Compressor Variable Speed Drive (VSD) .......................................................................58
15.1.4. Intermediate Load Outputs..............................................................................................58
15.1.5. HallScrew 2100 Series and 3100 Old Series Compressors ............................................59
15.1.6. HallScrew 3100 New Series, 3200 and 4200 Series Compressors.................................59
15.2. Proportional and Integral (P + I) Control ................................................................................59
15.2.1. Proportional Band ...........................................................................................................60
15.2.2. Integral Action Time ........................................................................................................62
15.2.3. Set Point Temperature/Pressure.....................................................................................62
15.3. Primary / Secondary Operation..............................................................................................63
15.3.1. Starting the Primary Compressor....................................................................................64
15.3.2. Starting and Stopping the Secondary Compressor .........................................................65
15.4. Starting and Stopping the Compressor ..................................................................................66
15.5. Control Philosophy for Compressor Operation After a Transmitter Failure............................68
15.6. Capacity Control by Fridgewatch Controller...........................................................................69
15.6.1. Auto Capacity Control .....................................................................................................69
15.6.2. Manual Capacity Control.................................................................................................69
15.6.3. Remote Capacity Control ................................................................................................69
15.7. Limiting Inputs........................................................................................................................70
15.7.1. Control Strategy for Limiting Inputs .................................................................................70
15.7.2. Current Limiting...............................................................................................................71
15.8. Pump-down............................................................................................................................71
15.9. High Pressure Cut-out Function by Transmitter.....................................................................72
15.10.Oil Management Systems......................................................................................................73
15.11.Summary of Differential Pressure Sensing ............................................................................74
15.12.Demand Oil Pump..................................................................................................................77
15.13.Oil Filling Pump......................................................................................................................78
16. Installation ................................................................................................................... 79
16.1. Analogue Inputs for Sensing Start, Stop and Set Point Values..............................................79
16.1.1. Using Two Start, Stop and Set Point Values...................................................................79
16.2. Digital Outputs .......................................................................................................................80
16.3. System Monitoring .................................................................................................................80
16.4. Installing Transmitters............................................................................................................80