ITV NDC-F18 Manual de usuario

NDC-F18
Access Control Panel
Installation Manual
NDC-F18
ACCCESS CONTROL PANEL
®

2Integrated Technical Vision http://www.itvsystems.com.ua

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 3
This manual covers installation, programming and utilization of NDC-F18 access
control panel. Read this manual carefully prior to installing and programming the unit.
Design Change Disclaimer
Due to design changes and product improvements, information in this manual is
subject to change without notice. ITV reserves the right to change product
design any time, which may subsequently affect the contents of this manual.
ITV assumes no responsibility for any errors that may appear in this manual. ITV
will make every reasonable effort to ensure that this Installation/Programming
Manual is up to date and corresponds with your shipped unit.
Reproduction Disclaimer
All rights on this document are preserved by Integrated Technical Vision Ltd.
Copying, printing and any other kind of reproduction of the document or its part
without permission of Integrated Technical Vision Ltd. is prohibited.
Trademarks
ITV® is a registered trademark of Integrated Technical Vision Ltd.
Training and technical support
Integrated Technical Vision Ltd. performs training on the installation, programming
and utilization of NDC-F18 access control panel. For additional information about
training and discussing of your particular requirements to the unit please contact
our personnel by the phone numbers below.
It is recommended to pass the training in Integrated Technical Vision Ltd. to person-
nel intended for sales and installation of NDC-F18 access control panel on perma-
nent basis. Technical support for all products of Integrated Technical Vision Ltd. can
be obtained at business time by the phones below:
+380 (0) 44 248 65 88
+380 (0) 44 248 65 89
+380 (0) 44 248 65 90
This support assumes the calls of trained specialists. End users must apply to
their dealers or installers before calling us.
This information is available on our web site www.itvsystems.com.ua

4Integrated Technical Vision http://www.itvsystems.com.ua

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 5
Contents
Preface .......................................................................................6
Features ............................................................................................... 6
Specifications ....................................................................................... 7
Terms ................................................................................................... 8
What's inside ............................................................................10
Wiring diagram ................................................................................... 11
Controls and connections on the board ............................................. 12
Control Panel Operation ............................................................ 13
Mounting ...................................................................................15
Wiring .......................................................................................16
Readers' connection .......................................................................... 16
Inputs' wiring....................................................................................... 16
RTE button ......................................................................................... 17
Door Contact ...................................................................................... 17
Door contact and RTE button ............................................................ 17
Free Pass and Blocking ..................................................................... 18
Executive devices .............................................................................. 18
Locking devices .................................................................................. 18
Sirens, Bells and agents .................................................................... 19
RS-485 Interface ................................................................................ 20
Address settings ......................................................................21
Limited Warranty .......................................................................22

6Integrated Technical Vision http://www.itvsystems.com.ua
Preface
NDC-F18 access control panel is designed for use in access control systems.
Primary goals of Access Control System are: identification of a person, confirmation
or not confirmation of access, control of movements in a necessary zone. It can
provide time and attendance logging, in addition to the usual task of restricting
individuals' access to certain areas.
All users' access information is gathered by a server, where administrators can
retrieve and analyze it. This data provides recording of staff movement within an
organization, whether it is a small company or a company that employs thou-
sands.
NDC-F18 panel operates as a total stand-alone unit with fully distributed database.
All valid card numbers, time zones and relay pulse times are loaded into controller's
memory. The panel controls access on two access points on a stand-alone basis
with no dependency on central computer system. Control panels are connected via
RS-485 dropline in Access Control Systems.
Features
o Supports all Wiegand reader technologies
o Distributed database for independent operation
o Operates in remote site configurations with dial-up (requires NDC-B052)
o 4-wire RS-485 communications, protection rated at 3000 V
o RS-232 communication port for local programming
o 8 supervised programmable inputs
o Tamper switch contact
o 4 Form C relays
o Up to 255 time zones to control card access
o Real time clock
o PC programming
o Local antipassback function
Preface

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 7
Specifications
Primary power supply ~220 +22 --44 V, 50 hertz
Power consumption of alternate current net 25 VA
Secondary power supply: 10.8 V... 38 V of continuous current
11V... 24 V of alternating current
Peak current 100 mA @ 12 V
Voltage ripple 500 mV @ 12 V
Inputs 8 programmable EOL supervised inputs
2 inputs for battery and power state control
Outputs Two 1 A @ 24 V relays
Two 5 A @ 24 V relays
Networking RS232/485 interface
Operation temperature 0° С… +55° С;
Relative Humidity 95% relative at +25° С;
Nonvolatile memory capacity is shown in the table below:
Overall dimensions 300х310х80 mm
Weight 2,45 kg
srotacifitnedI6904
stnevE4908
senozemiT052
seludehcS052
syadiloH052
Preface

8Integrated Technical Vision http://www.itvsystems.com.ua
Terms
Access point
Access point is a logical concept of the access control system implying the control
of passing through the door in one direction. It consists of reader, access control
panel (or it’s part), door supervision devices (like magnetic contact, RTE etc.) and
door locking device. For instance, the turnstile with two way passes has two
Access points – one for entrance and the other one for exit, door of this type is
called double-sided door. A door with the reader on one side has only one Access
point – Entry point, and it is called single-sided door.
Antipassback
The Antipassback function is implemented in the NDC-F18 access control panel in
order to prevent the situation when user gives his ID to another person after
passing to the premises. If this function is on, NDC-F18 tracks an ID position – Inside
or Outside the premises. On any attempt to pass in the same direction twice NDC-
F18 denies access and stores “Access Denied, Antipassback” event into the Log.
The antipassback function can be set on, only in case of the double-sided door
control.
Code matching
NDC-F18 can arise alarm in case of an attempt of a code (or ID) matching. The
Code matching is considered when invalid code (or ID) entered several times. Valid
code entrance clears the counter. This function switching on and number of code
entrances are subjects of programming.
Door Contact (DC)
In access control systems various sensors are used to supervise the status
(opened or closed) of the pass way – magnetic door sensor, sensor of the
turnstile rotor position, inductive sensor of car passing through the road barrier,
etc.
The Door Contact terminal of NDC-F18 is intended for connection of these sensors.
Door time
If the door contact is open, the corresponding access point goes into alarm.
Alarm is not invoked, if the contact is opened during the Door Time interval of
time. This interval starts when access is granted and lasts for the programmed
time or terminates on opening and subsequent closing of the door contact.
Downloading
NDC-F18 is to be downloaded after setting all parameters – modes of inputs,
outputs, access rights and others on the computer. During the downloading
parameters are rewritten into the access control panel. If you change control panel
parameters in your computer, they will not take effect until this parameters down-
loaded into the control panel.
PIN (Personal Identification Number)
Some readers have built-in keypad. The keypad may be used to enter ID in this
Preface

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 9
case. Usually this ID is named PIN (Personal Identification Number). It can be both
self dependant or used as an additional code for ID. When this PIN is .
programmed as additional code, NDC-F18 waits for PIN entrance after the ID read-
out. PIN is associated with ID.
Proximity Identificator
In access control systems each user has ID (identificator) with the unique code.
Proximity ID’s may be in shape of plastic card, key trinket, etc.
Reader
Readers are devices assigned for reading information from ID’s and transmitting
it to the control panel
There are several types of ID’s and readers for them. It is essential that reader
and control panel should use the same interface. NDC-F18 utilizes Wiegand
interface.
RTE (Request to Exit)
To exit from the premises with a single-sided door, the button wired to the
control panel is used. This button is called RTE (Request To Exit) button. If
someone opens the door otherwise than pressing the RTE button – by reenergizing
locking device, opening lock with a key etc., the Door Forced Open event arises.
RTE button may be used for remote door opening as well.
Schedules
NDC-F18 is capable to store up to 100 time zones. 100 week schedules can be
combined from these time zones, including 70 holidays.
Moreover NDC-F18 can store several “floating” schedules, based on the period
different to a week. The number of such “floating” schedules depends on the
period length.
“Several ID's” access
To access the high security premises the presence of more than one person
may be required . NDC-F18 allows assigning of up to 15 groups of people with the
access rights. The access is granted only in case when one person from each
group is present. For instance you have the room which can be attended only by
the personnel of R&D department escorted with guard. You can form two groups
for this access – group of R&D employees and group of guard. The access is
granted if two ID's from different groups read on panel readers – one belongs to
the R&D department employee and the other one – to a guardian.
Time zone
Any interval of time which has the beginning and the end.
Preface

10 Integrated Technical Vision http://www.itvsystems.com.ua
What's inside
The layout of NDC-F18 is shown on picture below.
Figure 1 View of the Panel inside the box:
1 - Mains power connection
terminal with fuse
2 - Transformer
3 - Power supply plate
4 - Box
5 - Control panel baseplate
6 - Battery
The wiring of the power
supply plate to the control
panel base plate is shown on
diagram to the right
What's inside
1
3
5
-+
~220 В50 Гц
26
GND1D01D11RD1GN|1BZZ1 GND Z2X1 Z3 GND Z4 +9V | C3 NO3 C1 NC1 NO1 |DCG ACG AC / DC X3
ITV NDC-F18
S3
S6
B- GND +EB |TMP GND| Z6 GND Z5Z8 GND Z72GN2RD2D12D0GND 2BZ|+9VC4|NO4C2NC2NO2A+
X2
F16-r5
X5 EXT. MODULE
IDN
RST
X4
RS232
4
primary winding
secondary winding
AC(24V) +12V GND PWG ACG
C1 X3
NC1 NO1 |DCG ACG AC / DC
transformer
secondary winding
Tabla de contenidos