ITV DLK642 Manual de usuario

Access
Control
Panel
DLK642
Installation
Manual
®
DLK642
A C C E S S C O N T R O L P A N E L

2Integrated Technical Vision Ltd http://www.itvsystems.com.ua

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 3
This manual covers installation, programming and utilization of DLK642 access
control panel. Read this manual carefully prior to installing and programming the
unit.
Design Change Disclaimer
Information due to design changes and product improvements in this manual is
the subject to change without notice. ITV reserves the right to change the
product design any time, that will subsequently affect the contents of this manual.
ITV assumes no responsibility for any mistakes that can appear in the manual.
The company guarantees that this Installation Manual is up to date and
corresponds with the unit you purchase.
Reproduction Disclaimer
All rights to this document are preserved by Integrated Technical Vision Ltd.
Copying, printing and any other kind of unauthorised reproduction of this
document or a part of it is prohibited.
Trademarks
ITV® is a registed trademark of Integrated Technical Vision Ltd.
Training and technical support
Integrated Technical Vision Ltd provides training in installation, programming and
utilisation of DLK642 access control panel. For detailed information about the
training and discussing of our particular requirements to the unit please contact
our personnel by the phone numbers below.
It is recommended, for the staff intended for sales and installation of DLK642
access control panel, to take instruction courses conducted by ITV company.
Technical support for all products of Integrated Technical Vision Ltd can be
obtained on business time by the following phones:
+380(0)44 248 65 88
+380(0)44 248 65 89
+380(0)44 248 65 90
This support assumes the calls of trained specialists. End users must apply to
their dealers or installers before phoning us. This information is available on our
web site www.itvsystems.com.ua

4Integrated Technical Vision Ltd http://www.itvsystems.com.ua
Contents
Preface.....................................................................................................................5
Features...................................................................................................................5
Specifications...........................................................................................................5
Terms........................................................................................................................7
What's inside............................................................................................................9
Controls and connections on board........................................................................11
Control Panel Operation.........................................................................................12
Main Mode ............................................................................... .................12
Alarm Mode ............................................................................. .................13
Free Pass Mode ...................................................................... .................14
Blocked Mode ......................................................................... .................14
Mounting..................................................................................................................15
Wiring......................................................................................................................15
Limited Warranty.....................................................................................................20

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 5
Preface
DLK642 is an access control panel which operates as totally stand-alone unit with
a fully distributed database. All valid card numbers, time zones and relay pulse
times are loaded to control panel memory. The panel can control access into two
doors with no dependency on a central computer system.
Primary goals of Access Control System are: identification of a person,
confirmation or not confirmation of access, control of movements in a necessary
zone. It can provide time and attendance logging, in addition to usual task of
restricting individuals’ access to certain areas.
All users' access information is captured on a server, where system managers
can retrieve and analyse the information. This data provides recording of staff
movement within an organization, whether it is a small company or a company
that employs thousands.
Features
• Supports all Wiegand reader technologies
• Distributed database for independent operation
• Operates in remote site configurations with dial-up (requires NDC-B052)
• Card, keypad or card and keypad access support
• On-board lithium battery for data storage
• 4-wire RS-485
• 8 supervised programmable inputs
• Tamper alarm
• 2 Form C relays
• Two transistor outputs
• Nonvolatile memory
• Local antipassback function
• Built-in buzzer
Specifications
• Inputs 8 programmable EOL supervised inputs
• Outputs
• Two 5 A @ 24 V relays
• Two open drain outputs 0.5 A @ 24V (with multifuse protection)
• Networking RS485 interface
• EPROM:
• Identificators 1024
• Events 1920
• Time zones up to 250
• Schedules up to 250
• Holidays up to 250
• Input Voltage +10…15 VDC
Features

6Integrated Technical Vision Ltd http://www.itvsystems.com.ua
• Voltage ripple 500 mV @ 12 V
• Power consumption:
• Standby current 80 mA@ 12V
• Maximal current 130 mA@ 12V
• Environmental requirements:
• Operation temperature 0 °С… +55 °С;
• Relative Humidity 80% relative at +35°С;
• Physical dimensions:
• Width 155mm
• Height 95mm
• Depth 32mm
• Weight 0,25 kG
Specifications

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 7
Terms
Access point
Access point is a logical concept of the access control system implying control of
passing through a door in one direction. It consists of reader, access control panel
(or its part), door supervision devices (like magnetic sensor, RTE etc.) and door
locking device. For instance, the turnstile with two way passes has two Access
points – one for entrance and the other one for exit, door of this type is called
double-sided door. A door with a reader on one side has only one Access point –
Entry point, and it is called single-sided door.
Antipassback
Antipassback function is implemented in DLK642 access control panel in order to
prevent the situation when user gives his ID to another person after passing into
the premises. If this function is on, DLK642 tracks an ID position – Inside or
Outside the premises. On any attempt to pass in the same direction twice
DLK642 denies access and stores “Access Denied, Antipassback” event into the
Log.
Antipassback function can be set on only in case of the double-sided door control.
Code matching
DLK642 can activate alarm on attempt of a code (or ID) matching. Code matching
is considered when invalid code (or ID) is entered several times succesively. Valid
code entering clears the counter. This function switching on and number of code
entrances are subjects of programming.
Door Contact (DC)
In access control systems various sensors are used to supervise door status
(opened or closed) – magnetic door sensor, sensor of the turnstile rotor position,
inductive sensor of car passing through the road barrier, etc.
Door Contact terminal of DLK642 is intended for connection of these sensors.
Door time
If door sensor is open, corresponding access point goes into alarm. Alarm is not
invoked, if contact is opened during Door Time interval. This interval starts when
access is granted and lasts for the programmed time or terminates on opening
and subsequent closing of door contact.
Downloading
DLK642 is to be downloaded after all parameters setting – modes of inputs,
outputs, access rights and others on PC. During downloading parameters are
rewritten into access control panel. If you change control panel parameters in
your computer, they will not take effect until this parameters are downloaded to
control panel.
PIN (Personal Identification Number)
Some readers have built-in keypad. Keypad may be used for PIN entering. It can
be both self dependant or used as an additional code to ID. When PIN is pro-
grammed as additional code, DLK642 waits for PIN entering after ID is read-out.
PIN is associated with ID.
Terms

8Integrated Technical Vision Ltd http://www.itvsystems.com.ua
Proximity Identificator
In access control systems each user has ID (identificator) with unique code.
Proximity IDs may be in shape of plastic card, keytrinket, etc.
Reader
Readers are devices assigned for reading information from IDs and transmitting it to
control panel
There are several types of IDs and readers for them. It is essential that reader and
control panel should use the same interface. DLK642 utilizes Wiegand interface.
RTE (Request to Exit)
To exit from the premises with a single-sided door, a button wired to control panel is
used. This button is called RTE (Request To Exit) button. If someone opens a door
otherwise than pressing RTE button – by re-energising locking device, opening lock
with a key etc., "Door Forced Open" event arises.
RTE button may be used for remote door opening as well.
Schedules
DLK642 is capable to store up to 250 time zones. 250 week schedules can be
combined from these time zones.
Moreover DLK642 can store several “floating” schedules, based on a period
different to a week. The number of such “floating” schedules depends on period
length.
“Several IDs' access
To enter high security premises presence of more than one person may be
required . DLK642 allows to assign up to 15 groups of people with the access
rights. Access is granted only in case when one person from each group is
present. For instance you have the room which can be attended only by
personnel of R&D department escorted with guard. You can form two groups for
this access – group of R&D employees and group of guard. Access is granted if
two IDs from different groups read by panel readers – one belongs to R&D
department employee and the other one – is a guardian.
Time zone
Any interval of time which has the beginning and the end.
Terms

http://www.itvsystems.com.ua Integrated Technical Vision Ltd 9
What's inside
General Configuration
The layout of DLK642 is shown on Diagram1 below.
Figure1. a). General view of DLK642, b) DLK642 with front cover off
1 - LEDs,
2 - built-in reader,
3 - backplate,
4 - panel's PCB,
5 - PCB of the reader,
6 - front cover.
2
a)
1
D1 D0 GN RDZ1 GND + ER BZZ2 GNDZ3Z4 GNDZ5Z6 GND
A+
B- GND + EB Z7 GND Z8 -PW R+ TM NC1 C1 NO1 NC2 C2 NO2 SA BEL
X1
S3
S4
S6
BAT
RST
S8
S9
X3
DLK
642
VL1
X2
X2
S5
3
4
5
6
б)
What's inside

10 Integrated Technical Vision Ltd http://www.itvsystems.com.ua
Wiring Configurations
Figure2.Terminals layout.
D1 D0 GN RDZ1 G N D + ER B ZZ2 G N DZ3Z4 G N DZ5Z6 G N D
A+
B- GN D + EB Z7 GN D Z8 -PW R+ TM N C1 C1 N O 1 N C2 C2 N O2 SA B EL
X1
S3
S4
S6
BAT
RST
S8
S9
X3
DLK
64
2
VL1
X2
X2
S5
Panel's PCB
PCB of built-in
reader
Bell
Locks or strikes
PC
RS485
Door Contacts
RTE's button
Free Pass
button
Door Blocking
button
Mains Status
Power Supply +12 В
Battery Status
External reader
What's inside
Tabla de contenidos
Otros manuales de Panel de control de ITV