Product Summary
The Power Line Carrier Card provides X-10 lamp
module and wireless siren features with a plug-in
card that is compatible with the following ITI®
Learn Mode™ security panels:
■Concord Hybrid Control Panel (60-734)
■Concord RF16 Wireless Control Panel (60-
735-95R)
Additional features include the following:
■Communication with ITI Supervised Wireless
Sirens and X-10 modules via existing AC
electrical wiring
■Simple “plug-in” functionality
■Adds ITI Supervised Wireless Sirens
compatibility for sirens in the event of an
alarm
■Adds X-10 module compatibility for light
control
■Light control by turning lights on either
individually, simultaneously, or through
programmed time schedules
Installation Guidelines
Follow the installation guidelines listed below:
■The panel must be powered by a Line Carrier
Power Transformer (P/N 60-762 or 60-779)
■Use 22 AWG (or larger) stranded wire to
connect the transformer to the panel
■All X-10 modules and ITI Supervised Wireless
Sirens must be plugged into electrical outlets
on the same electrical phase
■Avoid plugging the ITI Supervised Wireless
Sirens, transformers, and X-10 Lamp Modules
into outlets that share major appliances, such
as computers, microwave ovens, refrigerators,
dryers, or washing machines
■The Power Line Carrier Card, X-10 Lamp
Modules, and sirens require a programmed
house code in order to operate
Installation
This section describes how to install the Power
Line Carrier Card.
Installing in Concord Systems
Complete the following steps to install the Power
Line Carrier Card in both the Hybrid and Wireless
Concord systems:
1. Open the panel door.
WARNING: Wear a grounding strap to prevent static
electricity damage to the card and panel.
2. Unplug the AC power transformer and discon-
nect the panel backup battery.
3. Remove both 1/4” plastic jumpers that are pro-
tecting the Power Line Carrier Card headers on
the panel circuit board (see either Figure 1 or Fig-
ure 2).
60-755

Power Line Carrier Card
Page 2
Figure 1. Concord Hybrid Panel Circuit Board
Figure 2. Concord RF16 Wireless Panel Circuit Board
Figure 3. Power Line Carrier Card
Note: You can discard the jumpers, unless you plan
to eventually remove the Power Line Carrier
Card.
4. Insert the Power Line Carrier Card (see Figure 3)
solder side down and gently press into the panel
system board. (See either Figure 1 or Figure 2 for
the proper location of the Power Line Carrier
Card.)
5. Reconnect the panel’s backup battery and AC
power transformer.
When the installation is complete, see the
“Testing” section of this manual.
Programming and Light Control
For complete programming information, refer to
the specific panel’s Installation Instructions or the
ITI Supervised Wireless Siren’s Installation
Instructions.
Testing
Test ITI Supervised Wireless Sirens by arming the
panel, disarming it, bypassing sensors, etc. Test
light control by turning lights on and off
individually, simultaneously, or through
programmed time schedules.
SNAP
CARD
HEADER
POWER LINE CARRIER
CARD HEADERS
BACKUP BATTERY
CONNECTIONS
TERMINAL STRIP
8615G03A.DS
F
MICRO
PROCESSOR
PHONE LINE
–+
CARRIER CARD
SNAP CARD
HEADER
BACKUP BATTERY
CONNECTIONS
MICROPROCESSOR
PLC
CARD
–
POWER LINE CARRIER
CARD HEADERS
8615G04A.DSF
TERMINAL STRIP
ANTENNAE CONNECTORS
+
8615G01A.DSF

Power Line Carrier Card
Page 3
Troubleshooting
Table 1 describes problems you may experience
after connecting devices to your panel. Possible
solutions are listed in the Cause/Action column.
Specifications
Compatibility:
■Concord Hybrid Control Panel
■Concord RF16 Wireless Control Panel
Power Requirements:
■Input Voltages: +5 and +12 VDC
■Output Voltages: 4.2 V, peak to peak, across
5 ohm load
■Current Draw: Nominal = 110 mA
Idle = 10 µA
■Dimensions: 2.95” x 1.95” x.875”
(7.49 x 4.95 x 2.22 cm)
■Operating Temperature
10° to 120° F
(0° to 50° C)
Table 1. Troubleshooting
Problem Cause/Action
The light or siren will not
work. 1. The power transformer is
not line carrier compatible.
Replace it with a Power
Line Carrier Transformer
(60-672 or 60-779).
2. The house code is not
programmed into the panel,
ITI Supervised Wireless
Sirens, or X-10 modules.
Verify that the proper house
code is entered for all com-
ponents. Program the proper
house code if necessary.
3. Power Line Carrier isn’t
seated correctly. Remove
the card and gently press it
back onto the panel circuit
board.

Power Line Carrier Card
Page 4
Notices
Thisequipment hasbeen tested andfound to comply with the limits for aclass
B device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
■Reorient or relocate the receiving antennaon the radio or TV.
■Increase the separation between the equipment and receiver.
■Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
■Consult the dealer or an experienced radio/TV technician for help.
ITI is a registered trademark of Interactive Technologies, Inc.
Learn Mode and Concord are trademarks of InteractiveTechnologies, Inc.
651/777-2690
651/779-4890
Manuales populares de Hardware de computadora de otras marcas

EMC2
EMC2 VNX Series Manual del propietario

Panasonic
Panasonic DV0PM20105 Manual de usuario

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manual de usuario

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manual de usuario

Raidon
Raidon iT2300 Manual de usuario

National Instruments
National Instruments PXI-8186 Manual de usuario