IPS Controllers M920 Manual de usuario

M920 & M920W
pH/Dual ORP Controller
Owner’s
Manual


M920 & M920W pH/Dual ORP Controller Owner’s Manual
1
Table of Contents
I. Introducon 2
A. Water Chemistry 2
B. IMPORTANT SAFETY INSTRUCTIONS 3
C. System Components 4
D. Speci ca ons 7
E. Controller Panel Descrip ons 8
F. Electrical Descrip ons 10
II. Installaon 11
A. Setup 11
B. Tools 11
C. Procedure 11
D. Connec on Requirements for Remote Connec ng 15
III. Operaon 17
A. Overview 17
B. Startup and Shutdown 17
C. Modes and Adjustments 18
D. Maintenance 26
IV. IPS-M920 Wi-Fi Setup 28
A. Smart Phone Wi-Fi Setup 28
B. Desktop/Laptop Wi-Fi Setup 30
C. Remote Monitoring Setup 32
V. Troubleshoong 34
VI. Warranty 37

M920 & M920W pH/Dual ORP Controller Owner’s Manual
I. Introducon
A. Water Chemistry
Water chemistry is a complex science that contains many variables.
These variables not only aect the water environment itself, but they
can have adverse eects on your equipment as well as your health.
These are only some of the factors which we follow closely to ensure the
most healthy water interacons:
pH is the measurement of the acidity or basicity in an aqueous soluon.
A measurement below 7 is considered acid, while a measurement above
7 is base or alkaline. It is a signicant factor in determining the water
quality as it aects sanizer levels, water color, and human reacon to
the water.
ORP (Oxidaon Reducon Potenal) is the measurement of the oxidizing
capacity present in water. ORP cannot be fooled by the eects of pH,
total dissolved solids (TDS), stabilizers, and non-chlorine oxidizers.
A typical ORP sensor measures Hypochlorous Acid (HOCI), which is
the more eecve component of free chlorine. A higher ORP reading
equates to the sanizer working more eecvely.
Water balance is comprised of pH, calcium hardness, total alkalinity,
temperature, and TDS. When water is balanced, the Langelier Saturaon
Index is 0. Values above +0.3 lead to scaling and cloudy water, while
values below -0.3 can cause corrosion of pool equipment and surfaces. If
the water balance is not xed in a mely manner, secondary eects can
lead to rapidly declining water condions that can aect the health of
the water occupants.
pH and ORP work conversely to one another, and are aected by other
factors such as temperature, Cyanuric Acid, and TDS that can increase
the negave impacts of unbalanced water.
2

M920 & M920W pH/Dual ORP Controller Owner’s Manual
3
B. IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL
INSTRUCTIONS.
2. Risk of electric shock: Connect the controller to a dedicated ground-
fault circuit interrupter (GFCI) circuit breaker.
a. A green colored terminal or a terminal marked G, GR, Ground,
Grounding, or the symbol* is located inside the supply
terminal box or compartment. To reduce the risk of electrical
shock, this terminal must be connected to the grounding means
provided in the electrical supply service panel with a connuous
copper wire equivalent in size to the circuit conductors
supplying this equipment.
*IEC Publicaon 417, Symbol 5019.
3. Disconnect power before servicing the controller.
4. Inspect all power cords frequently. Any damaged cords should be
replaced immediately to reduce the risk of injury by shock.
5. Always maintain a record of manual water chemistry readings using
an accurate test kit. Automated controllers are not a substute for
this Health Department requirement.
6. WARNING – To reduce the risk of injury, do not permit
children to use this product unless they are closely supervised at all
mes.
7. Danger – Risk of injury.
a. Replace damaged cord immediately.
b. Do not bury cord.
c. Connect to a grounded, grounding type receptacle only.
8. WARNING – Risk of electric shock. Install at least 5 feet
(1.5m) from inside wall of water enclosure using non-metallic
plumbing.
9. Operaon of this controller without a funconing ow-switch will
void the NSF Cercaon.
10. WARNING – Do not install this controller where it is
accessible to the public.
11. SAVE THESE INSTRUCTIONS.

M920 & M920W pH/Dual ORP Controller Owner’s Manual
C. System Components
1. IPS M920 pH/Dual ORP Controller
a. Allows automac monitoring of water sanizaon and pH
balance through a simple, user-friendly interface, resulng in
easier management of water balance in swimming pools, spas,
or circulang water environments.
b. Can be easily installed into your exisng pool environment and
equipment, or can be customized to your needs.
c. Monitors and displays the pH and ORP levels using LEDs and
digital readouts on the front panel. If the temperature sensor is
installed, the M920 will monitor temperature and display on the
front panel when in Temp mode. Addionally. it will monitor up
to two chemical tanks equipped with level switches and displays
status using LEDs on the front panel.
There are six separate funcon buons that allow simple
pushbuon control of these individual parameters:
1. Set Level – ORP or pH level to be maintained,
2. Dose Time – Timed or connuous feed modes,
3. Delay Time – Delay me between feed cycles,
4. Over Timer – Maximum feed cycles or me allowed,
5. High Alert – Maximum level of ORP or pH allowed,
6. Low Alert – Minimum level of ORP or pH allowed,
7. pH Cal – pH calibraon for variaon in pH sensors.
d. When the pH level rises above (acid feed) or falls below (base
feed) the set level, the controller will acvate the chemical
feeder for the set dose me. Then the set delay me will occur.
This dose and delay me will occur unl the set level is reached.
e. When the ORP (sanizer) level reaches the set level, the
controller will acvate the chemical feeder for the set dose me.
Then the set delay me will occur. This dose and delay me will
occur unl the set level is reached.
4

M920 & M920W pH/Dual ORP Controller Owner’s Manual
2. Flow Cell with Flow Switch
a. An injecon-molded ow cell with integrated ow
switch houses the pH and ORP sensors, and partners with
the M920 controller to monitor the pH and ORP levels in
the water.
b. The ow switch veries that water is owing during a feed cycle,
and sends the controller instrucons to deacvate the feed if
water is not owing.
c. Operaon of this controller without a funconing ow-switch
will void the NSF Cercaon. Rounely check that the ow-
switch is funconing by closing the le valve on the boom of
the ow-cell (ow light should turn o).
3. pH and ORP Sensors
a. pH Sensor – standard (Use only IPS Controllers part # SXPH to
maintain NSF Cercaon)
b. ORP Planum Sensor – standard (Use only IPS Controllers part #
SXORP to maintain NSF Cercaon)
c. ORP Gold Sensor – for use with Salt Chlorine systems (Use only
IPS Controllers part # SXORP-G to maintain NSF Cercaon)
4. Fings – tubing connectors (2) for tapping installaon of ow cell
input/output
5. In-line Filter with 2-way valves and mounng clamps (2)
6. Tubing – 25 feet of 3/8”
7. Mounng Board – ABS plasc with mounng holes and stainless
hardware (16” x 12” standard, 24” x 19” oponal for mounng two
chemical pumps)
8. Temperature Sensor – Senses the current water temperature and
displays the temperature in the display when in Temp mode.
5

M920 & M920W pH/Dual ORP Controller Owner’s Manual
Figure 1: This is a typical installa on using IPS’ system package, which consists of an
M920 pH/dual ORP Controller, ow cell with switch, and two pumps mounted on the large board.
6
Chemical
Pump
Chemical
Pump
Flowcell (1)
Sucon Line
FLOW
FLOW
FLOW
Effluent
(to Sucon)
Waste
Influent (to Return Line)
Filter
Pump
FLOW
Filter
(10)
(aach to pipe with clamps)
FLOW
FLOW
Sample
pH sensor (3)
ORP
Sensor
(4)
Typical Installaon
Note: All chemical must be injected downstream from
the heater and flowcell.
Main Drain and Skimmer
Pressure Differenal
Return Line
FC100G
FLSW
SXPH
SXORP
SXORP-G
Valve
Jaco Fing 1/2”
Jaco Fing 1/4”
38tubing
Filter
1
2
3
4
5*
6
7
8
9
10
Flow Cell, Complete
Flow Switch Only
pH Sensor
ORP Sensor (Standard
Planum Tip)
ORP Sensor (Gold-Tip
for Salt Pools)
2-way Flow Cell Valve
1/2” Jaco fing for
sensors
1/4” Jaco fing for
tubing
3/8” tubing for
plumbing to/from
Flow Cell
Filter Strainer
IPS Parts List
Flow
Switch
(2) 1/2” Jaco Fing (7)
38tubing (9)
Valve (6)
* not shown
1/4” Jaco Fing
(7)

M920 & M920W pH/Dual ORP Controller Owner’s Manual
D. Specicaons
Enclosure: 7.95”L x 5.98”W x 3.54”D
Electrical Input/Output: 120/240 VAC, 50 - 60 Hz
ORP Set Level: 400 mV to 900 mV
pH Set Level: 7.0 to 8.0
Dose Time: O, Connuous, or Timed cycle
Delay Time: 1 - 99 minutes
Over Timer: O, 20-100 med cycles, or 20-180 connuous minutes,
default of 60
High Alert: pH default of 8.0, ORP default of 900
Low Alert: pH default of 7.0, ORP default of 100
Readout: Funcon LED and numerical digital displays
Alarm: Red alert LEDs with oponal external audible/visible alarm
7

M920 & M920W pH/Dual ORP Controller Owner’s Manual
E. ControllerPanelDescripons
1. Digital Displays and Func on LEDs
a. pH
1. Alert (High/Low) - red LED
2. Dose - green LED
3. Flashing Leds - Over Timer Alert
b. ORP
1. Alert (High/Low) - red LED
2. Dose 1 - yellow LED
3. Dose 2 - yellow LED
4. Flashing LEDs - Over Timer Alert
Figure 2: M920 Controller Components Connec ons
8
Electrical
Connec�ons
Flow Cell
Connec�ons
digital display
pushbutton
LEDs
Controller Communication
pH
pH
ORP
AC
Power
ORP2
ORP1
Flow
Switch
Temp
Sensor
Accessory