3
1. X1÷X6 –Terminals for connecting buttons
X1 For “Operator” mode: Menu scroll button - forward or up.
Button “Program 1 start”;
X2 For “Operator” mode: Menu scroll button –back or down.
Button “Program 2 start”;
X3 For “Operator” mode: Value change button.
Button “Program 3 start”;
X4 For “Operator” mode: Enter or exit a submenu.
Button “Program 4 start”;
X5 Button “Program 5 start”;
X6 “Stop”or “Pause/Stop” button.
2. X7÷X12 –Relay outputs. Independent contact type.
3. X15 –Terminal for connecting power supply board –2x9V/6VA.
4. X16 –Output 24V DC.
5. X17 –Input that can be used to accumulate amount, no validator required. The
value is determined from menu Settings: Validator - Line6.
6. X18 –“FAULT regime” signal input.
7. J2 –Connector for LCD indication plug in.
8. J4 –Connector for Validator RM5 type plug in.
9. J5 –Connector for LED indication plug in.
10.LED1÷LED6 –Service LED indication for the relay outputs.
Working mode Insert a coin or token into the coin mechanism.
Its value will be shown on the display and will
accumulate with each subsequent coin.
To start a program, press the button corresponding
to the number of the program you have selected.
The buttons are connected to terminals X1÷X6.
If the cost of the selected program is higher than the
amount value. A shortage message will be
displayed.
The program has been launched. The remaining
time is displayed with numbers and a graph. It can
also be monitored on the additional LED indication.