Intewa RAINMASTER Favorit Manual de usuario

0
RAINMASTER Favorit
Installationandusermanual
WATER,WE’REINOURELEMEN
T
www.intewa.com
New Zealand Distributor: [email protected]

1
Table of contents
1. Introduction and scope of application ........................................................................................................................................ 2
1.1Modes of operation ................................................................................................................................................................. 3
2. Safety instructions .............................................................................................................................................................................. 4
3. Scope of delivery ................................................................................................................................................................................ 5
4. Technical Data ..................................................................................................................................................................................... 6
4.1Device overview and dimensions ....................................................................................................................................... 7
4.2.Dimensions of the intake line .............................................................................................................................................. 8
4.3Standards, Directives, tests ................................................................................................................................................... 9
5. Overview of components ............................................................................................................................................................... 10
5.1Components of the pump-controller ............................................................................................................................... 10
5.2Components of the basic controller ................................................................................................................................. 11
5.2Components of the multistage pump ............................................................................................................................. 13
5.3Components of the supplemental supply container .................................................................................................. 15
5.4Components of the electronic 3/2-way ball valve ....................................................................................................... 15
6. Installation instructions ................................................................................................................................................................... 16
6.1Wall mounting .......................................................................................................................................................................... 16
6.2Connection to the mains water line .................................................................................................................................. 17
6.3Installation on the intake side ............................................................................................................................................. 18
6.3.1Installation of a protective conduit pipe ............................................................................................................ 18
6.3.2Layout of the intake line .......................................................................................................................................... 19
6.3.3Intake line connection .............................................................................................................................................. 20
6.3.4Installation of the floating intake ......................................................................................................................... 20
6.4Installation of the pressure line set ................................................................................................................................... 21
6.5Connecting the emergency overflow .............................................................................................................................. 21
6.6Installation and adjustment of the float switch ............................................................................................................ 23
7. Start up and use ................................................................................................................................................................................. 24
7.1Start-up in mains water mode ............................................................................................................................................ 24
7.2Start-up in rainwater mode .................................................................................................................................................. 25
7.3Modes of operation and display ........................................................................................................................................ 26
7.3.1Automatic mode (Switching position I ) ............................................................................................................ 27
7.3.2Maintenance mode (Switch position II )............................................................................................................. 27
8. Trouble shooting in case of problems ........................................................................................................................................ 28
9. Maintenance ....................................................................................................................................................................................... 29
10.Spare parts ........................................................................................................................................................................................... 29
11.Optional Accessories ........................................................................................................................................................................ 29
12. Guarantee............................................................................................................................................................................................. 30
13. Contact / Unit serial number ......................................................................................................................................................... 30

2
1. Introduction and scope of application
Congratulations on purchasing your RAINMASTER Favorit (RM Favorit).
The RM Favorit is specially designed for rainwater and greywater harvesting in large single family
dwellings, multiple family dwellings and in commercial and industrial applications. The maximum
installation height for toilets, washing machines and other applications, above the RM Favorit, is 15 m.
The RM Favorit is compatible with the following combinations:
Toilet / Urinal:
You can connect several toilets and urinals.
Washing machine:
You can connect several washing machines.
Garden / Cleaning:
You can connect all types of garden hoses and sprinklers as well as cleaning
devices, in line with the maximum pump flow rate of RM Favorit 20 or
RM Favorit 40 units.
Note:
A drip irrigation system may require a special layout in combination with an
expansion vessel.
Note:
The sizing of the system, with respect to the required maximum volume flow, is governed in Germany by
regulation DIN 1988-3.

3
1.1 Modes of operation
Automatic mode
In Automatic mode, the pump carries rainwater from the tank into the home and onto respective
applications (e.g. toilets etc.). If the tank is empty, this is detected by the float switch in the tank, which
instructs the electronic 3/2-way ball valve to change to the mains water mode. The rainwater intake line is
then blocked and the required mains water is sourced from the built-in supplemental supply container
inside the RM Favorit. After it rains, and the tank is topped-up with rainwater again, the float switch
detects this and the electronic 3/2-way ball valve switches back to the rainwater intake setting.
Maintenance mode
In Maintenance mode, the electronic ball valve stays permanently switched to mains water mode, and the
house is continuously supplied with mains water from the supplemental supply container inside the
RM Favorit.
In both working modes, the pump is switched on and off by means of the built-in pressure switch. The
anti-dry running protection of the pump, and the stagnation protection of the supplemental water supply
(the regular refreshing of water in the supplemental supply) are automatically controlled by the unit‘s
built-in pump-controller.
An example of a rainwater harvesting system with external storage
1. Rainwater module RAINMASTER Favorit
2. Mains water connection
3. Pressure line set with air vent and stopcock
4. Pressure line to house
5. Float switch cable
6. Suction line
7. Emergency overflow
8. PURAIN rainwater filter
9. Floating intake filter model SAUGSAGF
10. Quiet inflow
11. Protective conduit pipe for suction line and sensor cable
12. Rainwater line into the tank
13. MD100 wall bush

4
2. Safety instructions
This installation and operating manual is to be read carefully before installing the device. The instructions
specified here are to be accurately followed, as failure to do so may lead to rejection of any warranty
claim. This also applies to modifications to the RM Favorit. Moreover, any modification of the
supplemental supply device or the electronic inside the unit will immediately nullify the warranty.
The user is responsible for compliance with safety and installation regulations. Only the original provided
packaging is to be used for transportation of the equipment.
The emergency overflow of RM Favorit must always be connected.
Installation of the mains water line must only be carried out by an authorized installation company.
The RM Favorit internal housing for live electrical components shall only be opened by a
qualified electrician.
The electrical circuit used to power this device must be protected by a 16A circuit breaker. Likewise, an
ELCB (earth-leakage circuit breaker), with a maximum operating current of 30 mA, is to be used.
The operator is responsible for the compliance with safety regulations and for following these installation
guidelines.

5
3. Scope of delivery
RAINMASTER Favorit unit
Wall mounting material and
installation and user manual
Standard accessory A
(Mains water connection):
Standard accessory B
(Pressure line set):
Standard accessory C
(Float switch):

6
4. Technical Data
RM Favorit 20 RM Favorit 40
Dimensions (H x W x D) 595 x 550 x 265 mm 595 x 550 x 265 mm
Weight: 32 kg 33 kg
Power supply input: 230 V AC / 50 Hz 230 V AC / 50 Hz
Power rating: 0,8 kW 1,25 kW
Power intake: 4 A 5,8A
Motor capacitorr: 12,5 µF 20 µF
Max. operating pressure: 4,5 bar 5,5 bar
Max. volume flow rate: 80 l/min 110 l/min
Noise level: ca. 60 dBa ca. 65 dBa
Intake height (self-priming): see intake diagram see intake diagram
Pump start-up pressure: 1,0 – 2,2 bar (adjustable),
factory setting: 1,5 bar
1,0 – 2,2 bar (adjustable),
factory setting: 1,5 bar
Protection class: IP 54 IP 54
Max. mains water pressure: 2,5 - 6 bar 2,5 - 6 bar
Highest consumer above RM Favorit: 15 m 15 m
Float switch:
Cable length x Cross section:
15 m x Ø9 mm, (3 x 1,0mm²)
15 m x Ø9 mm, (3 x 1,0mm²)
Protection class: IP68 IP68
Performance curve of the pump
Performance curve of the intake

7
4.1 Device overview and dimensions
1. Multistage RM Favorit 20 / 40 centrifugal pump
2. Pump terminal box with basic controller
3. Vent cock
4. Pressure shut-off valve (3/4“ female)
5. Pump-controller
6. Supplemental supply container
7. Stopcock for mains water (3/4“ female)
8. Mains water floating valve
9. Electronic 3/2-way ball valve
10. Intake line (1“ female)
11. Emergency overflow line (DN 50/Ø55mm)
View from left
View from right Front view

8
4.2. Dimensions of the intake line
In practice, the self-priming function of the pump depends due to decrease in pressure (pipe friction,
suction level) only in a certain range. In this operating range, the pump can evacuate the air out of the
suction line (for example, with initial start-up operation). The performance curve of the intake line
indicates the dependence of intake length on the intake level. The determined value is above the
represented intake line in the diagram. If the intake point is below the intake performance line, then a
charging pump (optional accessory RMF-LP) is used to ensure the intake process proceeds reliably and
with sufficient safety.
Note: The charging pump boosts the water intake pressure, so that an intake level of up to 3 m high can
be attained. This means that, the performance curve moves 3 m parallel towards down.
Sample dimensions:
Example A:
Length of suction pipe: = 12 m
Intake level: = 2.40 m (Height difference between deepest intake level and pump)
o.k. because it’s above the performance curve
Example B:
Length of suction pipe: = 18 m
Intake level: = 3.20 m (Height difference between deepest intake level and pump)
not o.k. because it’s below the performance curve
RMF-LP (Article No: 22 00 76) charging pump is required, in order to boost intake pressure to meet
the requirements)

9
4.3 Standards, Directives, tests
The RM Favorit meets the DIN 1989-4 “Components for Control and Supplemental Supply“ standards for
rainwater harvesting systems.. The DVGW mark of approval confirms the presence of the mandatory „“air
gap“ (as per DIN EN1717) for secure separation of processed water from the mains water line, which is
integrated into the RM Favorit.
4
1
2
3
Mains water supplemental supply device, Type AB as per DIN EN 1717
The above mentioned device corresponds with the basic safety and health requirements of the
EC directives for machines. Any modification of the device not coordinated by INTEWA will void the
warranty. This equipment specifically fulfils the requirements of the following EU directives:
EC directives for machines (89/392/EWG) in accordance with 91/368/EWG
EC Low voltage directives (73/23/EWG)
EG Directives for electromagnetic compatibility (89/336/EWG) in accordance with
93/31/EWG
The conformity of the equipment with the above mentioned directives is confirmed by the CE symbol.
Applied harmonized EU standards:
EN 60335-1: 1194/A1/A11/A12/A13/A14, EN 60335-2-41: 1996
Applied standards and technical specifications:
DIN 1988-2, DIN 1989-4, DIN EN1717, DIN EN 13077, BGA KTW
Tests/Monitoring:
Mains water supplemental supply
device:
DIN-DVGW mark certified
1. Mains water inlet (floating valve)
2. Emergency overflow
3. Max. water level (in case of malfunction)
4. Air gap = secure separation of mains water and
processed water
Tabla de contenidos
Otros manuales de Sistema de agua de Intewa

Intewa
Intewa Rainmaster Favorit-SC 40 Manual de usuario

Intewa
Intewa RAINMASTER Eco Manual de usuario

Intewa
Intewa SEPAMAT F Manual de usuario

Intewa
Intewa AQUALOOP System GW 300 L Manual de usuario

Intewa
Intewa AQUALOOP greywater recycling Series Manual de usuario

Intewa
Intewa AQUALOOP GW 300 Manual de usuario
Manuales populares de Sistema de agua de otras marcas

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manual de usuario

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manual de usuario

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manual de usuario

Microline
Microline T.F.C.-4 Manual

Eureka Forbes
Eureka Forbes Aquaguard Select Manual de usuario

Cetetherm
Cetetherm AquaEfficiency Manual de usuario