Interflex Datensysteme GmbH 7/7
10 Remote Placement of the I/O Controller Board
To protect the I/O controller board against manipulation, it should be installed in a secured area.
It can, for example, be installed in a junction box together with the power supply. In such case, the terminal
strip board must be connected directly to the terminal.
A shielded cable should be used for the connection between the terminal strip board and the I/O
controller board.
The cable length may not exceed 100 m.
Adhesive tape for fastening the terminal strip board in the appliance case is included in delivery.
11 Technical Specifications
Electrical Data
Power Supply 12 - 24VAC/DC (measured directly at the terminal)
Power consumption Max. 4 VA
Protection Via PTC resistor
Interfaces RS485, 9600/ 19200 baud(automatic configuration)
Reader RFID reader, Mifare or LEGIC, depending on order
Read range Up to 50 mm, depending on the type of credential used
Sensor inputs 2 floating sensors on the I/O controller board
Output Relay, max. 30 V, 2 A
General Data
Ambient temperature -25°C to +55°C
Humidity max. 95%, non-condensing
Product safety EN 60950-1
Compatibility (EMC) EN 300330-1/2 EN 301489-1/3
Degree of protection IP65
Protection category III
Degree of protection
according to DIN EN 50102 IK 08
Dimensions Ø140 mm x 34 mm
Weight approx. 0.9 Kg
Material Anodized aluminum (matt-finish or black according to order), plastic insert
made of Makrolon
12 Disposal
Once its service life comes to an end, the device must be disposed of properly as
electronic waste. The owner can dispose of the device himself or return it to the
supplier.