7
Remove the board, then insert the battery (model CR2032), respecting the polarity.
CR 2032
3V
PAD PAD
FSK
PAD PAD
FSK
5.Registering the XAS 4010 Smart sensor
To register the XAS 4010 Smart sensor code in the alarm control panel, follow the
procedure below:
Insert the LITHIUM 3 Vdc battery - CR 2032, then type the command to register the
wireless device in the alarm center that will be used (Check the procedure in the
alarm center manual).Then perform a shot moving the magnet away from the sensor,
if the sensor is in a door for example, just open it observing if the LED will light up.
If the LED lights up, it indicates that there was a trip or transmission occurred, if the
LED does not light up, check the battery.
» Low battery sensor: the XAS 4010 Smart has a battery level meter, which me-
asures the voltage and noties you of the best time to change it, if the sensor
ashes the LED quickly in the opening, it indicates low battery level. If the alarm
center is Intelbras, the sensor low battery warning will be indicated on the product
panel. The sensor sends low battery warning in both OOK and FSK modulation.