2
BEFORE YOU BEGIN
• For your satisfaction and safety, read all instructions,
WARNINGS, CAUTIONS and NOTICES including
Important Safety Information section, before
installing or using this Instant Warm Handwash
System.
• This product contains stainless steel. The
manufacturer cannot guarantee against rusty water
because of the number of factors that are involved
beyond the manufacturer’s control. However, the
sudden appearance of rusty water discharged from
the faucet may indicate the need for service or
replacement of this product.
SYSTEM REQUIREMENTS
(HOT WATER TANK AND FAUCET):
• Make sure that all electrical, plumbing and
connections conform to local codes.
• A standard, earthed (grounded) electrical outlet, with
continuous supplied power, is required within 7 ft of
the tank.
• This outlet must be fused. Fuse/circuit breaker
required is 15 amp for 115 volt.
• Do not install on hot water supply lines.
• Incoming water temperature should be between 40°F
(4°C) and 80°F (27°C).
• It is recommended that a dedicated control valve
be installed on the cold water line supplying water
to this system.
• To prevent damage or the unit from not operating
properly, the incoming water pressure must be
between 30PSI-70PSI (210 kPa–483kPa; 2.1 bar– 4.8
bar), and the ambient (room) temperature between
40°F - 110°F (4°C–43°C).
• The use of a water filter should NOT result in the
water pressure dropping below 30PSI (210 kPa).
• Do not install where water hammer conditions occur.
If water hammer conditions exist, you must install a
water hammer arrester.
• To protect from freezing, shut off water supply,
drain water tank and tubing when temperatures are
expected to drop below 40°F (4°C); see Seasonal
Storage/Drainage section.
• Do not use a torch or other high temperature sources
near system, plastic fittings or plastic plumbing.
• Do not install near water pipes which will be in the
path of a drilling tool when selecting the position to
mount the bracket.
• Mount system in such a position as to prevent it
from being struck by other items used in the area
of installation.
• Ensure that the location and fasteners will support
the weight of the system when installed and full
of water.
• Ensure all tubing and fittings are secure and free
of leaks.
• Do not install using rigid piping. It is intended for use
with flexible water lines (such as PEX tubing,
PE tubing, PP tubing).
• Regularly inspect the system. If there are signs of
water leakage, turn off the water supply and contact
an authorized InSinkErator Service agent.
• Review the Uniform Plumbing Code (UPC) for other
related requirements.
• A drain pan, plumbed to an appropriate drain must
be used in those applications where any leakage
could cause property damage. A leak detection
device with water shutoff is recommended.
• For questions or concerns, please contact
InSinkErator Foodservice Sales and Service at
1-800-845-8345.
Introduction
The InSinkErator Instant Warm Handwash System provides at least 40 twenty-second, instantly warm handwashes at
100ºF (38°C) per hour,* with a touchless faucet. (see Figure 1 for typical installation).
Important – these installation instructions are for the benefit of the installing contractor. For technical information not
covered in these instructions, contact InSinkErator Foodservice Sales and Service at 1-800-845-8345.
*Based on cycles of 20 seconds on/40 seconds o, incoming water temperature of 40°F (4.4°C), and a tank set point of 105°F.

3
WARNING: Electrical Shock Hazard. To reduce
the risk of electrical shock, do not immerse or
expose the product, flexible cord, or plug to rain,
moisture, or any liquid or when standing in or on
damp or wet surfaces. If any electrical product
falls into the water, UNPLUG it immediately. DO
NOT REACH IN THE WATER. Important: prior to
reconnecting to the power supply, the product
should be inspected by a qualified technician.
This appliance must be earthed (grounded). This
water tank is equipped with a cord that has a grounding
conductor and earth ground pin. The plug must be
connected to an appropriate outlet that is properly
installed and earthed (grounded) in accordance with
all local codes and ordinances. Do not modify the plug
provided with the appliance – if it will not fit the outlet,
have a proper outlet installed by a qualified electrician.
Check with a qualified electrician or tradesman if you
are in doubt as to whether the water tank is properly
earthed (grounded).
• Use this water heater only for its intended use as
described in this manual.
• Do not operate this product if it has been or appears
to be damaged in any manner or after the product
malfunctions, or is dropped. Return the complete
product immediately to your retailer or dealer for
inspection.
• If the supply cord is damaged, the product must be
replaced in order to avoid a hazard.
• Do not connect to water supply exceeding 80°F (27°C).
• Do not connect to the water supply if the water
pressure exceeds 70 PSI.
IMPORTANT SAFETY INFORMATION
WARNING indicates a hazardous situation which, if not avoided, could result in death or
serious injury.
NOTICE is used to address practices not related to physical injury.
NOTICE
CAUTION indicates a hazardous situation which, if not avoided, could result in minor or
moderate injury.
SAVE THESE INSTRUCTIONS
WARNING: Personal Injury/Property Damage. To
reduce the risk associated with hazardous voltage
due to an installer drilling through existing electrical
wiring in the area of installation: Do not install near
electrical wiring or water pipes which may be in the
path of a drilling tool when selecting the position to
mount the system bracket.
Important: Always arrange the power cord so that
it cannot come in contact with hot surfaces.
• Do not disconnect the product by pulling
on the cord.
• The use of accessory attachments other than those
recommended by the manufacturer may cause
safety hazards.
• The recommended connection may be made to an
existing cold water line with a branch terminating
with a shut off valve.
WARNING: Electrical Shock Hazard. Using
an ungrounded (no earth ground) or improperly
connected appliance can result in serious injury
or death from electrical shock.
CAUTION: This product is intended to be used as
it was originally packaged. Do not use the system
if the Faucet End Piece has been removed.

4
WARNING: Personal Injury/Property Damage.
This tank is a pressurized tank. DO NOT modify
this system. DO NOT connect other types of
valves to the tank. Use only the InSinkErator faucet
supplied. Use only parts provided. Contact an
authorized InSinkErator Service agent for repairs or
replacement components.
WARNING: To reduce the risk associated with the
ingestion of contaminants: Do not use with water
that is microbiologically unsafe or of unknown
quality without adequate disinfection before or
after the system.
A water tank, like any water heater, has a limited life and
will eventually fail. To avoid possible property damage
and personal injury, this water tank should be regularly
examined for leakage and/or corrosion and replaced when
necessary. A drain pan, plumbed to an appropriate drain
must be used in those applications where any leakage
could cause property damage. A leak detection device
with water shutoff is recommended.
WARNING: Fire Hazard. To minimize possibility of
fire, DO NOT store flammable items such as rags,
paper or aerosol cans near the tank. DO NOT store
or use petrol or other flammable vapors and liquids
in the vicinity of this or any other appliance.
WARNING: Leak Hazard. Regularly inspect the
faucet and plumbing fittings for leaks, which
can cause property damage and could result in
personal injury.
NOTICE: Property Damage. To reduce the
risk associated with property damage due to
water leakage or flooding, and to ensure optimal
performance:
• Read and follow all instructions before
installation and use of system.
• Installation and use MUST comply with all state
and local plumbing codes.
NOTICE: Property Damage. Any water heater
should be installed in such a manner that if it
should leak, the resulting flow of water will not
cause damage to the area in which it is installed
and areas where the water could flow. National
plumbing codes require a drain pan for any water
heater installation. Failure to install one is the sole
responsibility of owner and/or installer. Reference
the latest version of the Uniform Plumbing Code
(UPC) for specific details and requirements.
IMPORTANT SAFETY INFORMATION
NOTICE: The maximum working pressure of 150
PSI refers to the rating of the temperature and
pressure relief valve. The pressure of the water
entering the water heater must be less than 70 PSI.
NOTICE: Property Damage. To avoid water
damage, replace any loose or split tubing.
Periodically inspect the unit for any sign of leakage
and immediately remove from service any unit
suspected of leaking.
NOTICE: T&P valves are typically designed and
manufactured to relieve pressure at 150PSI and
temperature at 210°F (98.9°C). ASME, ANSI and
CSA (AGA) approved relief valves protect the water
heater from excess pressures and temperatures by
discharging water.
When water is heated it expands. The extra volume
created by this expansion has to go somewhere or
pressure will dramatically increase, such as when
water is heated in a closed system.
In normal operation of the water heater and T&P
valve, no water should be discharged from the
valve. A relief valve functions by discharging water,
so it is essential that a discharge line be piped
from the valve in order to carry the overflow to a
safe place of disposal. This discharge line must be
the same size as the valve outlet and must pitch
downward from the valve. Discharge may indicate
that an unsafe temperature or pressure condition
exists which requires immediate attention by a
qualified service technician or licensed plumbing
contractor.
The T&P valve lever MUST be operated AT LEAST
ONCE A YEAR to ensure that the water-ways are
clear. Certain naturally occurring mineral deposits
may adhere to the valve, rendering it inoperative.
When manually operating the lever, water will
discharge and precautions must be taken to avoid
contact with hot water and to avoid water damage.
BEFORE operating lever, check to see that a
discharge line is connected to this valve directing
the flow of hot water from the valve to a proper
place of disposal, otherwise personal injury may
result. If no water flows, valve is inoperative. TURN
OFF THE WATER HEATER AND CALL A PLUMBER
IMMEDIATELY.

5
Overview of Complete Set-up
Note: Tank must be located within 16" (41 cm) of faucet
and within 84" (213 cm) or less of a standard dedicated
115-volt GFCI outlet. DO NOT extend plumbing or
electrical lines.
Figure 1 – Typical Installation Shown
Components In This Package
Ensure the incoming water line is connected,
shutoff valve is open, and the system is ready for
use prior to plugging in tank.
NOTICE
2"
(5 cm)
3/4" ( 2cm) screws 2 Set Screws (M5) 4

6
– Drill
– Pencil
– Adjustable Wrenches (2)
– Screw Driver
– M2.5 Hex Key
– Discharge Pipe
– Water Supply Hose
– Tape Measure
– Level
– Basin Nut Wrench
– Thermometer
– Shutoff Valve
– Anchors
SUPPLIES YOU MAY NEED:
SUPPLIES NEEDED:
Required Tools/Materials
Sink Mount Configurations (4" Centers)

7
n Identify locations for the faucet and tank.
n Check to make sure counter is not too thick.
n Make sure there is a GFCI outlet under the sink.
The wall outlet for your faucet must have power
supplied to it continuously and must be fused.
n If drilling a hole into a stainless steel sink or counter
top, you can cut a mounting hole for the faucet with
a hole saw for stainless steel, or you can use a hole
punch. Consult a professional before drilling into
a surface other than stainless steel.
Required minimum from center of hole to wall
Maximum counter thickness (depth)
2" (51 mm)
5
/
8"(16 mm)
A
Required hole size (diameter)
1"–1½" (25– 38 mm)
These instructions are separated into main sections,
indicated by numbers, and subsections, indicated by
capital letters. The manual is setup this way to allow you
to take a break at any point after completing a section or
subsection without affecting the installation process.
How To Use This Instruction Manual
Provides a step-by-step narrative describing
the installation step, with tick boxes that can be
marked as you progress through the installation.
Contains simple illustrations that provide visual
instruction to support the narrative.
WARNINGS, CAUTIONS and NOTICES that will
require your attention during the step.
1
2
3
ELECTRIC SHOCK HAZARD
Appliance must be grounded.
1. PREPARATION
Proper installation should take 2-4 hours.
Installation
A
Turn off water supply.
B
or splash mount configuration.
Decide on deck mount...
B
C

8
2. ASSEMBLY OF FAUCET
1
1
1
Install spout into faucet base and tighten set
screw to secure.
2
1
1
1
1
3
2
Install threaded sleeve(s) into bottom of faucet.
A
2
2
2
After inserting sensor connection wire, install sensor
into faucet base. Tighten set screw to secure.
3
1
B
C

9
4. MOUNTING THE TANK
PROPERTY DAMAGE
Tank must be located within 16" (41 cm) of faucet
and 84" (213 cm) or less of a GFCI outlet, to
accommodate the supplied 7' cord. DO NOT
extend plumbing or electrical lines.
NOTICE
3. INSTALLING THE FAUCET
PROPERTY DAMAGE
Do not pinch wires or tubing.
NOTICE
4
Feed hose, sensor wire and threaded sleeve(s)
into hole until faucet rests on deck/splash.
1
5
2
From underneath or behind sink, install washer(s)
and large nut(s) onto threaded sleeve(s). Use an
adjustable wrench to secure.
2
2
7
3
1
Screws provided are for use in wood studs or
cabinets only. Use wall anchors for installation
into drywall. Turn screws into pre-drilled holes,
leaving 1/4" (6 mm) exposed. Hang the tank
on the screws. Tighten the screws with only
1/2 turn clockwise.
A
B
1
1
6
3
2
From underneath the sink, place tank against
the wall and mark hole locations. Pre-drill
1/8" (3 mm) pilot holes at marks.
C
D

10
5. CONNECT FAUCET TO TANK
PROPERTY DAMAGE
• Pinched or blocked water lines may cause
damage to the tank.
• Check to make sure tubes are connected properly
and are pushed down as far as possible.
NOTICE
1
8
Connect cold water hose to tank fitting. Secure
connection using a wrench while tightening the hose.
2
9
Insert tubing into fitting from the faucet hose and
press until it bottoms out. Pull on connections to
insure tubes are fully seated. Tube should insert
approximately 5/8".
10
Connect sensor from faucet to sensor from tank.
Be sure to align arrows on connectors.
6. CONNECT DRAINAGE PIPE
A
B
C
6"6"
1
11
2
Install a 3/4" inside diameter discharge pipe to
the T&P Valve (sloped for proper drainage). The
discharge pipe should be terminated within 6"
from the floor at a suitable place for disposal.
D
Tabla de contenidos
Otros manuales de Sistema de agua de InSinkErator
Manuales populares de Sistema de agua de otras marcas

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manual de usuario

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manual de usuario

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manual de usuario

Microline
Microline T.F.C.-4 Manual

Eureka Forbes
Eureka Forbes Aquaguard Select Manual de usuario

Cetetherm
Cetetherm AquaEfficiency Manual de usuario