INOR ICON-X Diagrama de cableado

Accessories for Inor transmitters
Including the Ex-approved USB-interface ICON-X
Transmitter configuration kit
INOR TRANSMITTERS
INOR TRANSMITTERSINOR TRANSMITTERS
INOR TRANSMITTERS Supplementary Instructions
Supplementary InstructionsSupplementary Instructions
Supplementary Instructions
© INOR 07/2018 - 4006932901 - AD ICON-X ConSoft R01 en

CONTENTS
2
www.inor.com 07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
INOR TRANSMITTERS
1 Configuration kit 3
1.1 General safety notes......................................................................................................... 3
1.2 General information ......................................................................................................... 3
1.3 Certifications .................................................................................................................... 3
1.3.1 EU directive compliance ......................................................................................................... 3
1.3.2 Ex approvals............................................................................................................................ 4
1.4 Scope of delivery............................................................................................................... 4
1.5 Nameplate ........................................................................................................................ 4
1.6 Technical data................................................................................................................... 5
2 Installation 6
2.1 General safety notes......................................................................................................... 6
2.2 Safety Diagram ................................................................................................................. 6
2.3 Installation of USB interface drivers................................................................................ 6
2.4 Installation of configuration software ConSoft................................................................ 7
2.5 Description of USB interface ICON-X............................................................................... 7
2.6 Installation guide for ConSoft and USB-Interface drivers............................................... 7
2.7 Troubleshooting................................................................................................................ 8
2.8 Disassembling and recycling of Transmitter configuration kit ICON-X.......................... 9
2.9 Disassembling and recycling of USB Interface ICON-X ................................................ 10
2.10 Installation and control drawing .................................................................................. 12
3 Notes 13

CONFIGURATION KIT
1
3
INOR TRANSMITTERS
www.inor.com07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
1.1 General safety notes
1.2 General information
The configuration kit includes all necessary software and hardware for configuration of the
temperature transmitters from a PC´s USB port.
Configuration starts from the main program ConSoft. ConSoft will identify the connected
transmitter and open the necessary configuration software.
ICON-X configuration kit consists of:
•USB interface ICON-X
•USB cable (connection between PC and USB interface)
•Adapter cables (connection between USB interface and transmitter)
•Software and drivers on a USB memory stick
The configuration kit is compatible with Windows XP (SP3), Windows Vista, Windows 7, Windows
8, Windows 8.1 and Windows 10.
1.3 Certifications
1.3.1 EU directive compliance
The USB interface, used with the provided cables, is CE-marked and complies with the EMC
directive 2014/30/EU based on the harmonised standard EN 61326-1:2013, the ATEX-directive
2014/34/EU based on the harmonised standards EN 60079-0:2012 including A11 and EN 60079-
11:2012. and the ROHS directive 2011/65/EU, based on the harmonised standard EN 50581:2012.
For more information refer to the Declaration of Conformity, which can be found in the download
area of the manufacturer's website.
For other cables than the provided and with cable length ≥3 m / 9.8 ft. other requirements are
valid and are not covered by this EMC directive.
CAUTION!
The USB interface ICON-X is an Ex-approved product that is intended to be used for all type of
transmitters when in safe areas.
DANGER!
ICON-X is the Ex-approved connection between a PC USB interface and an INOR Ex-approved
transmitter. It may be used with non-Ex approved Inor transmitter as well. The ICON-X must not
be used in hazardous area. Consult the user instruction and Ex-certificate of the used
transmitter regarding the possibility to configure "online" if the input of the transmitter is
connected to hazardous area.
DANGER!
ICON-X contains no reparable parts. Repairing or fixing the circuit or replacing components may
impact the intrinsic safety.
CAUTION!
Only one transmitter may be connected at a time.

1
CONFIGURATION KIT
4
INOR TRANSMITTERS
www.inor.com 07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
1.3.2 Ex approvals
USA and Canada:
EX-approvals according to: FM 3600, ANSI/ISA 60079-0, CAN/CSA C22.2 No. 0,
CAN/CSA C22.2 60079-0, FM 3610, ANSI/ISA 60079-11, CAN/CSA C22.2 60079-11
See also "Special conditions for safe use" in the Ex certificates in the download area of the
manufacturer's website.
1.4 Scope of delivery
1.5 Nameplate
ATEX KIWA 16ATEX0011X II (1) G [Ex ia Ga] IIC
IECEx IECEx KIWA 16.0005X [Ex ia Ga] IIC
USA FM18US0117X AIS CL I, Div 1 and 2, GP A-D,
CL I, Zn 0, 1 and 2, [AEx/Ex ia Ga] IIC
Canada FM18CA0056X
Figure 1-1: Scope of delivery
1 USB communication cable (connection between PC and USB interface)
2 USB interface
3 Mini USB to Mini USB adapter (USB interface to transmitter)
4 Mini USB to four pole rectangular connector (USB Interface to transmitter)
5 Mini USB to 3.5 mm tele plug connector (USB Interface to transmitter)
6 Mini USB to three pole rectangular connector (USB Interface to transmitter)
1 PN = Part number
SN = Serial number (yyww = year and week of manufacturing)
PO = Batch number
PN: 70USBIX001
SN: Nyyww.xxxxxx
PO: ZZZZZZZZZ
PO Box 9125
SE-200 39 Malmö
SWEDEN
0539 II (1)G [Ex ia Ga] IIC
KIWA 16ATEX0011X
IECEx KIWA 16.0005X
www.inor.com
USA FM18US0117X
Canada FM18CA0056X
AIS CL I, Div 1 and 2, GP A-D,
CL I, Zn 0, 1 and 2 [AEx/Ex ia Ga] IIC
WARNING: SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY
Per Control Drawing
No. 4006801801
Um 250 V AC/DC
0 Ta +50 °C

CONFIGURATION KIT
1
5
INOR TRANSMITTERS
www.inor.com07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
1.6 Technical data
Operating conditions
Ambient temperature 0...+50°C / +32...+122°F
Storage temperature -20...+70°C / -4...+158°F
Humidity (non-condensing) 0...90% RH
Installation
Installation For detailed information, refer to chapter "Installation".
Dimensions USB interface Length: 114 mm / 4.49"; width: 36 mm / 1.42" ; heigth:
26 mm / 1.02"
Electrical connection
Power supply PC's USB port; 5 VDC; 74 mA max.
Galvanic isolation 1500 VAC
Input (PC to USB interface) USB cable type A to type B
Output (USB interface to transmitter) Changeable adapter cables
System requirements
Windows Windows XP (SP3), Vista, 7, 8, 8.1 or 10
Display resolution Minimum 800x600
Free hard disk space 185 MB
PC Port 1x USB 1.1 or higher port type A
Ex parameters
Comm.port (PC connection) Um = Vmax : 250 V AC/DC
Output port (to transmitter) Uo = Voc : 9.4 VDC
Io = Isc : 96 mA
Po : 680 mW

2
INSTALLATION
6
INOR TRANSMITTERS
www.inor.com 07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
2.1 General safety notes
2.2 Safety Diagram
2.3 Installation of USB interface drivers
Before you can use the USB interface you must install the USB drivers on your PC. The setup file
includes drivers for the USB interface and can be installed manually when running the setup file.
The drivers can also be installed automatically by using Windows Update if the computer
supports this function.
For detailed information refer to section "Installation guide for ConSoft and USB-Interface
drivers".
All software, USB drivers and installation guides can also be downloaded from the website.
CAUTION!
The USB interface ICON-X is an Ex-approved product that is intended to be used for all type of
transmitters when in safe areas.
DANGER!
The transmitter's communication port (USB connection) may only be connected to the certified
ICON-X interface. When the ICON-X is connected, the temperature transmitter shall be outside
of the hazardous area; a connected sensor may be located in the hazardous area.
1 Hazardous Area
2 Safe Area
3 Temperature Sensor
4 Temperature Transmitter
5 ICON-X USB interface
6 Ex-approved Power Supply/ Zener barrier
7 PC
ICON-X

INSTALLATION
2
7
INOR TRANSMITTERS
www.inor.com07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
2.4 Installation of configuration software ConSoft
All necessary software for configuration are included on the memory stick or can be downloaded
from the website of the manufacturer.
For detailed information refer to section "Installation guide for ConSoft and USB-Interface
drivers".
All software, USB drivers and installation guides can also be downloaded from the website.
2.5 Description of USB interface ICON-X
The USB interface ICON-Xis powered from the PC´s USB port. There are three LED indicators on
the USB interface: "USB", "PC" and "DEV". They are indicators to make the understanding of the
communication between PC and transmitter easier. Their functions are described below:
•"USB" LED indicates data transfer. It lights during data transfer, otherwise it is off.
•"PC" LED indicates connection between configuration program and PC. It is green only during
reading or writing to transmitter.
•"DEV" LED indicates the transmitter connection status. If it’s green, the connected
transmitter is detected by the USB interface. Flashing green indicates that the USB interface
is waiting for a new transmitter from the same product family, e.g. changing to a new device.
When it´s red no transmitter is detected by the USB interface and any sort of transmitter can
be connected to the USB interface.
2.6 Installation guide for ConSoft and USB-Interface drivers
Locate the executable setup file “ConSoftSetup”. Double click on the file to start the installation
process and follow the instructions on screen.
CAUTION!
The installation guide must be read prior to installation.

2
INSTALLATION
8
INOR TRANSMITTERS
www.inor.com 07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
2.7 Troubleshooting
Error message Action
Error message "USB Interface is not installed. The
program will not work." displayed when starting
ConSoft.
Install drivers for the USB interface.
Error message "USB Interface:s hardware and/or
software should be updated." appears in ConSoft. Contact us for update of your USB interface.
Error message "Unable to install because a newer
version of this product is already installed." is
displayed during installation of ConSoft.
A newer version of ConSoft is already installed on
the computer. If you still want to install the older
version, uninstall ConSoft through "Control Panel –
Add or Remove Programs".

INSTALLATION
2
9
INOR TRANSMITTERS
www.inor.com07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
2.8 Disassembling and recycling of Transmitter configuration kit ICON-X
This section describes (in short) the instructions of handling and disassembling the device when
it’s reached EOL (end of life) or is disposed of after usage. The information given is sufficient to
gather the most important parts of the device (by the end-user) which can be used for recycling.
Content of USB configuration kit ICON-X
Content of USB configuration kit ICON-XContent of USB configuration kit ICON-X
Content of USB configuration kit ICON-X
Figure 2-1:
Item No Item Name Weight
(g)
Weight
(lb)
1USB communication cable (connection between PC and USB interface
ICON-X) 42 0,09
2USB Interface ICON-X 63 0,14
3Mini USB to Mini USB adapter (USB interface ICON-X to transmitter) 17 0,04
4Mini USB to four pole rectangular connector (USB interface ICON-X to
transmitter) 23 0,05
5Mini USB to 3.5 mm tele plug connector (USB interface ICON-X to
transmitter) 19 0,04
6Mini USB to three pole rectangular connector (USB interface ICON-X to
transmitter) 24 0,05
7USB memory 15 0,03
8Case polypropylene 300 0,66
9Foam cushioning PU 20 0,04
Total 521 1,15
Table 2-1: USB configuration kit ICON-X
Item 1 and 3 - 7; sorted as electrical waste
Item 2; sorted according to chapter 2.9
Item 8 and 9; sorted as plastic.

2
INSTALLATION
10
INOR TRANSMITTERS
www.inor.com 07/2018 - 4006932901 - AD ICON-X ConSoft R01 en
2.9 Disassembling and recycling of USB Interface ICON-X
Item 2 (Table 2-1) USB Interface ICON-X consists of
DANGER!
The device MUST be disconnected from mains power before disassembling.
Wear personal protective equipment. Make sure you use a steady workplace/bench to do the
disassembly actions.
CAUTION!
Before disassembling the device, make sure you have the proper tools needed:
- Torx Screwdriver T9
- Philips head Screwdriver #1
Item No Item Name Weight
(g)
Weight
(lb)
1Label, upper side polyester 0 0
2Label, bottom side polyethylene 0 0
3General purpose ABS plastic package box (UL94-HB) 38 0,08
4PCB Glass fiber reinforced Epoxy 10,6x2,9 cmm
2
22 0,05
5Cover Screws threaded, 2 pieces (4x3/4 self-tapping oval head 19,1 mm) 2 0
6Sealing washer, 2 pieces 0 0
7PC Board Screws, 2 pieces (4x1/4 self-tapping oval head 6,4 mm) 0 0
Total 63 0,14
Table 2-2: USB configuration interface ICON-X
Tabla de contenidos
Otros manuales de Transmisor de INOR

INOR
INOR IPAQ R202 Manual de usuario

INOR
INOR APAQ C130 TC Manual de usuario

INOR
INOR IPAQ C520 Manual de usuario

INOR
INOR IPAQ-4L Manual de usuario

INOR
INOR IPAQ C330 Series Manual de usuario

INOR
INOR Mini IPAQ-HLP Manual de usuario

INOR
INOR APAQ-HRF Manual de usuario

INOR
INOR IPAQ-H/HX Manual de usuario

INOR
INOR APAQ R130 Manual de usuario

INOR
INOR APAQ C130 Manual de usuario
Manuales populares de Transmisor de otras marcas

Dejero
Dejero EnGo 3x Manual de usuario

Rosemount
Rosemount 4600 Manual de usuario

Speaka Professional
Speaka Professional 2342740 Manual de usuario

trubomat
trubomat GAB 1000 Manual de usuario

Teledyne Analytical Instruments
Teledyne Analytical Instruments LXT-380 Manual de usuario

Rondish
Rondish UT-11 Manual de usuario