Inngenso IT WiFi v2 Manual de usuario

...step by step
Thermostat
Manual
IT WiFi v2 | EN


3
EN WIRELESS DIGITAL WiFi THERMOSTAT IT WiFi v2
The IT WiFi v2 thermostat is designed to control heating
systems. Unlike standard home thermostats, the IT WiFi v2
has two separate and wirelessly connected units (thermostat
+ receiver) and the mobile application Inngenso that allows
monitoring and controlling of the heating system.
The receiver is a switching device used to connect heating
systems, and a thermostat is a portable control unit for han-
dling and setting the temperature. The units communicate
with each other using a radio signal. The receiver also com-
municates with the mobile app using WiFi. The advantage
of the system is the variability and easier availability of tem-
perature control.
Important notes
• Read the user manual not only for the thermostat, but also
the heating system.
• Turn off the power supply before installing the thermostat.
• We recommend installation by a qualified technician.
• Be aware of the required standards for installation.
• The electrical circuit should be secured with a fuse that
does not exceed 20 A.

4
Specifications
Thermostat
Receiver
Mobile app
230 V AC
2000 W (At 70 °C)
L, N, COM, NC, NO
868 MHz and 2.4 GHz
120 x 90 x 25 mm
2.4 GHz
TLS (SSL)
IP20
0 °C – 70 °C
Power supply
Maximum switching power
Input /Output
Communication frequency
Dimensions
WiFi
Data encryption
Ingress protection rating
Operating temperature
0.2 °C – 5 °C
-5 °C – 5 °C
Yes
Android 7.1 / iOS 5 or higher
Free
Hysteresis settings
Temperature sensor calibration
Weekly mode
Platform
Download and update
Power supply
Mounting
RF Communication
Manual control
Frost protection
Window open detection
Weekly mode
Sensitivity
Temperature setting
Temperature measurement
Dimensions
3 V DC, 2 AA baterries
Wall or portable
868 MHz, *CS, FEC
Full
Yes
Yes
Yes
0.5 °C
5 °C – 35 °C
5 °C – 40 °C
86 x 86 x 29 mm
* Checksum, Forward error correction

5
Safety
Risks due to poor handling
Due to poor handling of the product you can harm yourself
and cause material damage.
• Read the accompanying instructions carefully, especially
the chapter on safety and important notes.
Danger of malfunctioning
• Ensure that the air in the room can circulate freely around
the thermostat and that the thermostat is not covered by
furniture, curtains and other objects.
• Only operate the heating system if it is in technically per-
fect condition.
Behaviour in case of loss of wireless
communication
Low voltage in the batteries that power the thermostat may
result in interruption of wireless communication. In the event
of a loss of wireless communication between the receiver
(heating system switching unit) and the thermostat (room
control unit):
• On the receiver: yellow light is blinking.
• On thermostat’s display: time and current temperature are
shown. The symbol “--” is shown instead of the set temperature.

6
If the battery icon is shown on the thermostat that means
that the batteries have reached the voltage limit for which
the device can operate without any problem. In this case it
is highly advised to replace the current batteries with new
ones. The thermostat can still function with these batteries,
but it is much more error-prone.
NOTE: In case when communication is lost, the receiver
immediately switches off the heating. After that, the heating
can be turned on via the mobile app by applying a set tem-
perature higher than 5.0 °C.
When the power supply comes back after the power outage
the receiver remains in its last state. If after 12 minutes the
communication with the thermostat is not established, it will
turn off the heating. In this case the heating can be turned
on and controlled only via mobile app by setting the set
temperature higher than 5.0 °C.
Freezing damage due to too low room
temperature
If the room temperature is set too low in some rooms, the
heating system can be damaged due to freezing:
• Ensure that during the frost period the heating
system remains in operation and that all rooms during your
absence are sufficiently heated.
• Default frost protection temperature is 5 °C and can be
changed in the range from 0 to 17 °C. Frost protection
can be enabled or disabled via mobile app.

7
Proper use of the device
Improper use can result in health and life hazards to the
plant operator or third parties.
This product is not intended for use by people (including
children) with limited physical, sensory or intellectual abili-
ties or people without experience and / or knowledge, un-
less they are under the supervision of a person in charge of
their safety or have been instructed by that person to use
the product.
Children must be supervised to ensure that they do not play
with the product.
Intended use includes:
• Following the included instructions for use, installation
and maintenance of the device, as well as all other system
components.
• Compliance with all inspection and maintenance require-
ments stated in the instructions.
This thermostat can be used to control gas boiler, pellet
stove, pellet boiler, under floor heating or any other heating
system that uses potential free contact interface.
Use that is different from the one described in this manual
or use that goes beyond the scope of the use described here
will be considered as non-intended.
It is not intended for any direct commercial or industrial use.

8
Overview of command elements
Room thermostat
Receiver
1. Receiver ON/OFF/Auto Button
2. RGB light signal indicators
• RED - Heating request is active
• GREEN - Device is turned on but there is no heating request
• BLINKING BLUE - Bluetooth Connect mode
• BLINKING YELLOW - There is no communication between the thermostat and the receiver
• BLINKING GREEN - Receiver is in pairing mode
1. Display
2. Left button for decreasing the value
3. Middle button for confirmation of selection
4. Right button for increasing the value
1
2 43
12

9
Display description
Description of the main display
Description of the settings display
Advanced settings
Setting the time
bC - Bluetooth connect
Return to the previous screen
Setting the program
Eco mode
Comfort mode
Antifrost mode
Overview of the functions
on the settings display
Child lock
Open window detected
Internet connection
Program mode
Set temperature
Current room temperature
Heating indicator
Time
Days of the week
Setting the program
Manual mode
Battery low
Overview of the basic functions
Connection to receiver
Weekly program
Eco mode
Comfort mode
Antifrost mode

10
Temperature setting
1. Press the RIGHT button to increase the set temperature.
2. Press the LEFT button to decrease the set temperature.
Setting the working mode
There are 4 working modes of the thermostat: SYSTEM OFF
mode, Manual mode, Program mode and Antifrost mode. To
access each mode you need to press on the middle button
until the icon you wish to set the temperature of, appeares
on the top of the screen. To better understand read appears
through explanations comming in the following pages.
SYSTEM OFF mode
1. Press the MIDDLE button to enter MANUAL mode.
2. The upper left end of the screen shows the symbol .
3. While thermostat is in MANUAL mode press and hold
LEFT button decrease temperature to minimum 7 °C.
4. Press and hold LEFT button for 5 sec. to enter SYSTEM
OFF mode.
5. To exit SYSTEM OFF mode press and hold MIDDLE but-
ton for 5 sec
SYSTEM OFF mode is active
Tabla de contenidos
Otros manuales de Termostato de Inngenso
Manuales populares de Termostato de otras marcas

EWELLY
EWELLY EW-181 Manual de usuario

Prolon
Prolon T1100 Instrucciones de instalación

Computherm
Computherm Q20 Manual de usuario

Heatmiser
Heatmiser neoStat Manual de usuario

Aube Technologies
Aube Technologies TH111GFCI-NP 240 VCA Manual de usuario

Mars
Mars HEAT CONTROLLER IR Wireless Thermostat Manual de usuario