InfoBionic MoMe 01854 Manual de usuario

MoMe® Kardia System Patient Guide

page 2
10135 revI
InfoBionic’s MoMe® Kardia System may be covered under one
or more United States and International Patents. Please see the
website: www.infobionic.com to satisfy the virtual patent
marketing provisions including the America Invents Act and 35
U.S.C. § 287(a). Additional patents may be issued or pending in
the US and elsewhere.

page 3
Table of Contents
MoMe® Kardia System Components ................................................. 4
Unpacking MoMe® Kardia Device ..................................................... 5
Monitoring ......................................................................................... 6
Device Controls ................................................................................ 7
Notifications ...................................................................................... 8
Belt Clip ............................................................................................ 9
Charging Battery Pack ......................................................................... 9
Installing Battery Pack ....................................................................... 10
Removing Battery Pack ...................................................................... 11
Warnings ........................................................................................ 12
Cautions ......................................................................................... 13
Battery Information ......................................................................... 14
System Specifications ..................................................................... 15
Electromagnetic Emissions Compliance ......................................... 16
SAR Exposure Information ............................................................. 19

page 4
MoMe® Kardia System Components
MoMe® Kardia Kit Components
No.
Component Description
1
Monitor Small, lightweight battery operated device that
collects, stores, and transmits physiological data
to the remote server via built in cellular module
1
Lead Set Attaches to the MoMe® Kardia monitor and
to each electrode
1
Belt Clip Used to carry the MoMe® Kardia monitor on
your belt or waistband during the day
2
Rechargeable
Battery Pack
Battery packs to power the MoMe® Kardia monitor.
A fully charged battery will last for 24 hours and
must be replaced with a charged battery each day
to ensure uninterrupted monitoring
1
Charger Dock Used to charge the battery packs
1
Charger Dock
Power Cord Used to connect the charger dock to AC wall socket
-
Electrodes The lead set snaps to the electrodes.
Electrodes will be provided by your physician
Inspect all parts before use to ensure nothing is damaged and/or missing.

page 5
Unpacking MoMe® Kardia Device
Unpack the MoMe® Kardia Kit and locate components
listed in the Kit Components chart above.
Plug in the charger dock and place one of the
two included battery packs in the charger.
Insert the second battery pack into the back of
the Monitor (for more detailed instructions, see
diagram on page 10). The device should turn on.
Attach the lead set to the monitor.
Place electrodes as indicated on page 6.
You are now monitoring.

page 6
Monitoring
Once the monitor is activated and operating, the system requires
no intervention to capture or analyze data. However, your physician
should instruct you about the following responsibilities:
•
Charge the battery pack every day
•
Report any symptomatic events by pressing the event
record button as instructed by your physician
•
Return the system to the practice at the end of monitoring
Front of body

page 7
Device Controls
The MoMe® Kardia monitor has three buttons:
Event Record, Wake, and Volume.
Wake Button
Volume
Button
Event Record
Button
Wake: Press the wake button at any time to display the current battery
level status.
Volume: Press the volume button to adjust the volume or silence alerts
on the monitor. To adjust the volume, press up or down on the volume
button. The display will be updated with the current level and a tone
will be played at the current volume for audible feedback of the volume
level. The lowest volume setting mutes the speaker and can be used
when the patients sleep should not be disturbed. Pressing the volume
button one more time after the lowest volume setting sets the monitor to
vibrate mode.
Volume Up
Volume Down
Vibrate

page 8
Device Controls continued
Event Record: Press the event record
button located on the face of the
device to report a symptomatic event.
The screen will display a solid heart
when the event has been recorded.
Press and hold the Event Record
Button for 3 seconds to record
Notifications
Low Battery: When the battery level
is low, the device will play an audio
alert and will display the BATT LOW
notification shown below.
When the battery level is low the screen
will display BATT LOW

page 9
Belt Clip
The MoMe
®
Kardia Monitor must
be used with the included belt clip.
Slide the monitor up and into the belt
clip holster to secure the monitor
in place then slide the clip over
your belt or waistband with the lead
set attachment facing upwards.
Charging Battery Pack
To charge the Battery Pack:
•
Slide the battery pack into the charger dock until the
charging indicator turns red and the battery pack stops.
•
The battery pack is fully charged – when the indicator light
turns green.
Note: Each battery pack takes approximately 3 hours to fully charge.
Insert battery Charge in progress Charge complete
Red
Green

page 10
Installing Battery Pack
To install the Battery Pack, follow these steps:
1. Place the battery pack into the monitor, pushing down
until it is fully seated.
2. Slide the battery pack towards the slide lever lock.
3. Battery is installed when you hear the slide lever lock “click”.
Slide Lever Lock
Slide Lever Lock
Slide Lever Lock