Libelium MySignals Manual de usuario

MySignals
User Manual

-2-
Index
© Libelium Comunicaciones Distribuidas S.L.
INDEX
1. Introduction......................................................................................................................................... 3
2. General and safety information ......................................................................................................... 3
3. MySignals’s Hardware Setup .............................................................................................................. 4
3.1. Power Supply.................................................................................................................................................................................4
3.2. Sensors.............................................................................................................................................................................................5
3.3. Data Visualization......................................................................................................................................................................10
3.4. Mini USB Data Transfer............................................................................................................................................................11
3.5. Wireless Communication ......................................................................................................................................................11
4. MySignals Software Installation ...................................................................................................... 11
4.1. MySignals Updater Tool..........................................................................................................................................................11
4.2. MySignal Web Server Application.......................................................................................................................................12
4.3. MySignals Mobile APP.............................................................................................................................................................12
5. Accessing MySignals Data................................................................................................................. 13
5.1. MySignals Standalone Screen ..............................................................................................................................................14
5.2. MySignals Web Server Application.....................................................................................................................................15
5.3. MySignals Mobile APP.............................................................................................................................................................18
6. Updating a New Firmware to MySignals.......................................................................................... 20
6.1. MySignals Updater Tool.........................................................................................................................................................20
7. Certications Information ................................................................................................................ 20
7.1. USA and Canada Certication .............................................................................................................................................21

-3-
1. Introduction
The aim of this manual is to introduce the user to MySignals in a practical way.
This document applies to MySignals product, approved for FCC and IC:
Model FCC ID IC
MySignals XKM-MYSIGNAL-V1 8472A-MYSIGNALV1
2. General and safety information
The following list shows just some of the actions that produce the most common failures and warranty-voiding cases.
Failure to comply with the recommendations of use will entail the guarantee cancellation.
Software:
• Update rmware version only using MySignals Updater Tool. If a dierent Software is used, MySignals can be damaged
and can become unresponsive. This use is not covered under warranty.
• Use only MySignal Web Server Application or MySignals Mobile APP in order to congure and setup your account and
device.
• Do not unplug any connector while uploading code. MySignals can become unresponsive. This use is not covered under
warranty.
• Do not connect or disconnect any sensor or connector while MySignals is ON. MySignals can become unstable or
unresponsive, and internal parts can be damaged. This fact is not covered under warranty.
Hardware:
• Do not handle black stickers seals on both sides of the enclosure (Warranty stickers). Their integrity is the proof that
MySignals has not been opened. If they have been handled, damaged or broken, the warranty is void.
• Do not open MySignals in any case. This will automatically make the warranty void.
• Do not handle the four metallic screws of MySignals.
• Do not submerge MySignals in liquids.
• Do not place nodes on places or equipment where it could be exposed to shocks and/or big vibrations.
• Do not expose MySignals to temperatures below -10ºC or above 50ºC.
• Do not connect any sensor not provided by Libelium.
• Do not power MySignals with other power sources than the original provided by Libelium.

-4-
3. MySignals’s Hardware Setup
All the items included in the basic kit of MySignals are in their specic compartiments in MySignals briefcase.
Figure : Mysignals briefcase
3.1. Power Supply
General power supply
Operating Current 2 A
Operating Voltage 5V
Input Voltage (recommended) 12V
Input Voltage (limit) 10-20V
Specic power supply
DC Current per I/O Pin 20 mA [Max]
DC Current for 3.3V 1 A [Max]
DC Current for 5V 1 A [Max]
DC Current for 4 V Pin 2 A [Max]
Plug in /out the power supply adapter included with MySignals to turn ON or OFF the device. Make sure that the power adapter
is indoors.
Plug it into the corresponding power supply connector. At Libelium we oer equipment for operating at 12V, do not use other
power supplies.
You can see all the information about the power supply in the label included in MySignals device.

-5-
3.2. Sensors
Figure : Mysignals sensors
You can nd all the sensor connectors indicated in both sides of the device.
Figure : Mysignals sensor connectors

-6-
Connect the correct sensor in each specic connector as you can see in the following images:
Figure : Connecting one sensor
This information is used to monitor in real time the state of a user or to get sensitive data in order to be subsequently analysed
for biometric analysis. Biometric information gathered can be wirelessly sent using two connectivity options available: Wi-Fi or
Bluetooth Low Energy 4.0.
Figure : MySignals BLE sensors
Data can be sent to the Cloud in order to perform permanent storage or visualized and storaged in real time by sending the
data directly to a Smartphone. iPhone and Android applications have been designed in order to easily manage and storage the
user’s information.
Snore Sensor
Description: This sensor attaches to the neck and records vibration associated with a piezo sensor.
Measurement:
Parameter Unit Range
Respiratory rate BPM (breaths per minute) 0-60 bpm

-7-
Patient Position Sensor
Description: The Patient Position Sensor (Accelerometer) monitors ve dierent user positions (standing/sitting, supine, prone,
left and right.). Body Position Sensor uses a triple axis accelerometer to obtain the user’s position.
Measurement:
Parameter Unit Range
Body Position Dimensionless 5 dierent positions
Body Temperature Sensor
Description: Exacon D-S18JK sensor allows you to measure this key parameter for body monitoring.
Measurement:
Parameter Unit Range
Body Temperature Degree Celsius (°C) 0-50ºC
Electromyography Sensor (EMG)
Description: An electromyograph detects the electrical potential generated by muscle cells when these cells are electrically or
neurologically activated. The signals can be analyzed to detect biometric abnormalities, activation level, recruitment order or to
analyze the biomechanics of human or animal movement.
Measurement:
Parameter Unit Range
Muscle signal Volts 0-5V
Electrocardiogram Sensor (ECG)
Description:The electrocardiogram (ECG) is a diagnostic tool that is routinely used to assess the electrical and muscular functions
of the heart. The sensor use “Continuous telemetry electrocardiogram” for a prolonged monitoring including the use of three
ECG electrodes.
Measurement:
Parameter Unit Range
Electrocardiogram signal Volts 0-5V
Airow Sensor (Breathing)
Description: The nasal / mouth airow sensor is a device used to measure the breathing rate in a user in need of respiratory help
or person. This device consists of a exible thread which ts behind the ears, and a set of two prongs which are placed in the
nostrils. Breathing is measured by these prongs.
Measurement:
Parameter Unit Range
Respiratory rate BPM (breaths per minute) 0-60 bpm
Breathing intensity Volts 0-3.3V

-8-
Galvanic Skin Response Sensor (GSR - Sweating)
Description: This sensor measures the electrical conductance of the skin, which varies with its moisture level. This is of interest
because the sweat glands are controlled by the sympathetic nervous system, so moments of strong emotion, change the
electrical resistance of the skin.
Measurement:
Parameter Unit Range
Conductance Siemens 0-20Siemens
Resistance Ohms 10K-100KOhms
Voltage Volts 0-5V
Blood Pressure Sensor (Sphygmomanometer)
Description: Blood pressure is the pressure of the blood in the arteries as it is pumped around the body by the heart. When
your heart beats, it contracts and pushes blood through the arteries to the rest of your body. This force creates pressure on the
arteries. Blood pressure is recorded as two numbers—the systolic pressure (as the heart beats) over the diastolic pressure (as
the heart relaxes between beats).
Measurement:
Parameter Unit Range
Systolic pressure mm Hg 0-300 mmHg
Diastolic pressure mm Hg 0-300 mmHg
Pulse ppm 30~200 ppm
Auxiliar input 1
Description: This are generic inputs for possible a UART interface sensors
Auxiliar input 2
Description: This are generic inputs for possible a UART interface sensors
Pulse and Oxygen in Blood Sensor (SPO2)
Description: Pulse oximetry a noninvasive method of indicating the arterial oxygen saturation of functional hemoglobin. Oxygen
saturation is dened as the measurement of the amount of oxygen dissolved in blood, based on the detection of Hemoglobin
and Deoxyhemoglobin. Two dierent light wavelengths are used to measure the actual dierence in the absorption spectra of
HbO2 and Hb.
Measurement:
Parameter Unit Range
Pulse ppm 25~250 ppm
SPO2 % 35-100%

-9-
Spirometer
Description: MSA100 Peak Flow Meter is a hand-held pulmonary function measuring device that measures your maximum
possible exhalation which is called peak expiratory ow (PEF) and forced expiratory volume in 1 second (FEV1). FDA,ISO,CE.
Measurement:
Parameter Unit Range
Volume l 0.01L~9.99L
Air ow l/min 50 L/min ~900L/min
Wireless Electroencephalography sensor (EEG)
Description: EEG headset that safely measures and transfers the power spectrum (alpha waves, beta waves, etc) data via
Bluetooth to wirelessly communicate with the device. This headset can be simply slipped on to be able to see your brainwaves
change in real time.
Measurement:
Parameter Unit Range
Brain waves: alpha waves,
beta waves... Percentage 0-100%
Wireless Blood Pressure Sensor (Sphygmomanometer)
Description: Blood pressure is the pressure of the blood in the arteries as it is pumped around the body by the heart. When
your heart beats, it contracts and pushes blood through the arteries to the rest of your body. This force creates pressure on the
arteries. Blood pressure is recorded as two numbers—the systolic pressure (as the heart beats) over the diastolic pressure (as
the heart relaxes between beats).
Measurement:
Parameter Unit Range
Systolic pressure mm Hg 0-300 mmHg
Diastolic pressure mm Hg 0-300 mmHg
Pulse ppm 30~200 ppm
Pulse and Oxygen in Blood Sensor (SPO2)
Description: Pulse oximetry a noninvasive method of indicating the arterial oxygen saturation of functional hemoglobin.
Oxygen saturation is dened as the measurement of the amount of oxygen dissolved in blood, based on the detection of Hemo
and Deoxy.
Measurement:
Parameter Unit Range
Pulse ppm 25~250 ppm
SPO2 % 35-100%

-10-
Wireless Body Scale
Description: Multipurpose personal portable digital weight health body scale
Measurement:
Parameter Unit Range
Weight Kilograms 5-150Kg
Bone Percentage 0-100%
Body fat Percentage 0-100%
Muscle mass Percentage 0-100%
Body water Percentage 0-100%
Visceral fat Percentage 0-100%
BMI Kcal 0-500Kcal
BMR Kcal 0-500Kcal
3.3. Data Visualization
The e-Health library include graphic TFT for visualizing data. This 2.4S-inch TFT LCD serial SPI integrated features of compact, SPI
interface, fully compatible with popular LCD5110 interface cable sequence.
As a bonus, this display has a resistive touchscreen attached to it already, so you can detect nger presses anywhere on the
screen.
Feature:
• TFT01_2.4 SP is a 2.4 “SPI TFT LCD Screen Module
• 3.3V Power Supply pin
Figure : MySignals top view
Tabla de contenidos