Impulse ECOMIZER-PRO Manual de usuario


Introduction
Congratulations on your purchase of an Impulse Pump unit with ECOMIZER-PRO
control technology.
The ECOMIZER-PRO is an emissions-reducing and fuel-saving mobile pump and engine
controller that can automatically handle the unit's performance based on the changing
conditions in a pump pit. Adjusting the revolution cycles depends directly on the
amount of supplied medium that needs to be pumped.
Pump units equipped with the ECOMIZER-PRO offer the best of both worlds - the
mobility of a self-operating diesel pump set with the full flexibility of a frequency-
controlled electric fixed installation. With the ECOMIZER-PRO control technology, both
diesel and electric driven mobile pumps can achieve significant emissions reductions
and fuel savings of up to 55% when compared to similar equipment without this
technology.
The ECOMIZER-PRO achieves full automation with comprehensive log data on the
pump's use, such as operating hours, production days, hours until the next service,
and/or time-related warnings or alarms when exceeding adjustable limits. The user can
choose some limits and/or parameters attuned to their own operations.
The ECOMIZER-PRO, with optional internet connection, allows you to remotely monitor
and even operate the pump set from any computer with internet connection.
Introduction

INDEX ECOMIZER-PRO
4. Manual Control
5. Level Control
1. Screen Activation
2. Starting Screen
3. Ecomizer-Pro Explanation
p. 1
p. 2
p. 3
7. Fault Codes
8. Info Screens
9. Login Screen
p. 4
p. 7
p. 20
p. 22
p. 25
6. Battery Recharge
10. Time Settings
p. 19
p. 29

1
1. Screen Activation
All Impulse Pumps equipped with ECOMIZER-PRO are operated using only a single
switch. To activate the display, keep the switch in the “Start” position until the display
lights up (approximately 5 seconds). Once it has lit up, you can release the switch, which
will return to the “On” position. In the “On” position, the unit is active for remote
operation.
Please be aware that the pump is in Stand-By mode as soon as the switch is in “On”
position. Maintenance, repair, and/or transportation should never be done with the
switch in “On” position.
1. To start the ECOMIZER-PRO: Hold the “Off-On-Start” switch on the control box in
the “Start” position, and wait until the Touch Screen display appears.
2. After these 3 seconds the switch can be released, and it return to its “on” position.
When no further actions are made during the shutdown delay (standard on 2
minutes) the ECOMIZER-PRO will switch itself into Stand-By. To reactivate the
ECOMIZER-PRO the user has to turn the switch on “start” again, or when applied
(optional), the pump can be started by Remote Control.
3. The “Off” position will shut down the Pump Unit completely. This position can be
used as emergency stop. Make sure the ECOMIZER-PRO is on “Off” while
maintaining, repairing, transporting or being stored.
Screen Activation
Switching to “Off” Position has the same working as an
emergency stop

2
2. Starting Screen
Depending on the purchased software version there are three possible starting screens
available:
Starting Screen
Manual Control (Only)
The Manual Control (Only) software option is mostly used on smaller pump sets which
are generally operated on site. See Manual Control section to discover all advantages.
Level Control (Only)
The Level Control (Only) software option is mostly used for larger pump sets for which
Ecomizer-Pro can help reduce mistakes caused by human error.
Ecomizer-Pro
The Ecomizer-Pro software option gives the user the choice of using either manual
control or level control.
The pump will
automatically shut down
in Stand-By mode as soon
as there are no further
interactions with the
display for more than 120
seconds.

3
From this point on the manual is based on the Ecomizer-Pro software version. The
Manual Control Only and Level Control Only are both explained separately.
Starting Screen
To change the Touch Screen language, press the [Language] button.
Select the preferred language by pressing the flag on the pop-up.
3. Ecomizer-Pro Explanation
Note:
USA flag uses the Imperial system (PSI, Inch, Ft, and Gallons/h).
All other flags use the Metric system (Bar, Metre, Litre, m3/h).

4
4. Manual Control
Manual Control
Be aware that RPM adjustment is only possible as soon as the system has been primed
(full of water). As long as there is no water present, the REV UP and REV DOWN buttons
are not being displayed on the screen.
As soon as “START MANUAL CONTROL” has been selected the following screen
appears:
The pump starts up after 5 seconds and a warning beep is given. You can stop the start-
up procedure at any time by pressing the red “STOP” button.
In manual control you can activate the pump unit and set the RPM value according to
your preferences.
Activate Manual Control by pressing START MANUAL CONTROL

5Manual Control
As soon as the pump has started the following screen appears:
Air in suction hose is
displayed by “AIR
DETECTED” and a blue dot.
Vacuum pump is active.
General Data
As soon as the pump has been primed “REV UP” and “REV DOWN” buttons appear.
Vacuum pump is active and
will turn off when the pump
is primed (full of fluid) for
more than 20s.
REV UP and REV DOWN
buttons together with
setpoint.
Air in system
System
primed
Slide show:
•Flow rate
•Pressure
•Vacuum

6Manual Control
4.1 Main screen during operation (Manual Control)
Vacuum pump
is not active
(system is fully
primed)
Manual set
setpoint (RPM)
RPM bar. In this unit from
1000 RPM to 1800 RPM.
1000 1800
RPM
If air is detected and the pump starts snoring/slobbering the RPM will automatically fall
down to idle RPM (in this case 1000 RPM). The setpoint is still in memory and as soon as
the system is fully primed again, the unit will automatically rev up to its setpoint.
Remarkable Advantages:
4.3 Intelligent Manual Control by ECOMIZER-PRO
4.2 Air Snoring in Manual Control
In manual control the pump will keep on running even when air is detected.
The automatic shut-down of the unit after 900s of priming air is ONLY in this
mode not activated. As air is detected the unit will rev down to 1000 RPM,
vacuum pump will be activated, and the pump will keep on priming/snoring.
•Fuel Reduction
•Emission Reduction
•Noise Reduction
•Wear Reduction
•Extended Lifetime

7
5. Level Control
Level Control
Level Control provides the advantage that the pump performance is automatically adjusted
to the available amount of medium (flow). The units come equipped with a hydrostatic
pressure sensor and/or a ball float switch. The two connectors for the sensors have different
connection points (4 pins or 5 pins), eliminating the possibility of connection mistakes. This
needs to be connected in the pump set.
Activate Level Control
If there are no sensors connected the following screen appears indicating that the level
sensor needs to be connected.
There are three possible ways of connecting the level sensors. Every sensor is creating
its own distinct display.