IFM QHA200 Manual

Instructions for set-up
moneo|appliance
QHA200
V1.4 or higher
80294622 / 0102 / 2021
GB

QHA200
2
Contents
1 Preliminary note.............................................................. 3
1.1 Symbols used........................................................... 3
1.2 Further documents....................................................... 3
2 Safety instructions............................................................ 4
3 Intended use ................................................................ 5
4 Function.................................................................... 6
5 Installation .................................................................. 7
6 Electrical connection .......................................................... 8
6.1 Wiring................................................................. 8
7 Set-up...................................................................... 9
7.1 Requirements........................................................... 9
7.2 Preparations............................................................ 9
7.3 Set-up of moneo|appliance................................................. 9
7.3.1 Adapting the hostname................................................ 10
7.3.2 Adapting the IP address - Ethernet interface 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7.3.3 Set-up completed .................................................... 11
7.4 Opening the appliance management system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
7.4.1 Requirements ....................................................... 11
7.4.2 Initial login via the browser ............................................. 11
7.5 Opening moneo......................................................... 12

QHA200
3
1 Preliminary note
You will find instructions, technical data, approvals and further information using the QR code on the
unit / packaging or at www.ifm.com.
1.1 Symbols used
Requirement
Instructions
Reaction, result
[...] Designation of keys, buttons or indications
Cross-reference
Important note
Non-compliance may result in malfunction or interference.
Information
Supplementary note
1.2 Further documents
• Software manual moneo|appliance
The documents can be downloaded at: www.ifm.com
GB

QHA200
4
2 Safety instructions
• The unit described is a subcomponent for integration into a system.
– The system architect is responsible for the safety of the system.
– The system creator undertakes to perform a risk assessment and to create documentation in
accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.
• Read this document before setting up the product and keep it during the entire service life.
• The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.
• Only use the product for its intended purpose (Ò Intended use).
• If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.
• The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.
• Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.
• Protect units and cables against damage.

QHA200
5
3 Intended use
IT hardware to operate moneo; incl. management system for appliance maintenance.
GB

QHA200
6
4 Function
The appliance management system (AMS) allows the user to carry out basic maintenance tasks for
the moneo|appliance, e.g.:
• Setting the network configuration and hostnames
• Setting of date and time
• Rebooting or shutting down the moneo|appliance
• Monitoring and restarting services
• Importing software updates
• Displaying contact details for technical support
• Setting the access for remote support
• Reading log files
• Data backup
The moneo|appliance is used to run the following software:
• moneo|configure for setting the parameters of connected devices
• moneo|RTM for monitoring the process data
The required licences to operate the moneo products must be ordered separately.

QHA200
7
5 Installation
uDisconnect the power of the machine before installation.
uIntegrate the device into the control cabinet. The following has to be observed:
• Fasten the device on a plane mounting surface using the enclosed angle brackets.
• Use 4 M5 mounting screws and washers for fastening.
The device is rated for convection cooling.
uDo not impede the air circulation. Adhere to installation distances.
Observe the operating conditions for the device specified in the data sheet. Further information at:
www.ifm.com
GB

QHA200
8
6 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical equipment must be
adhered to.
uDisconnect power.
uConnect the unit as follows:
6.1 Wiring
2 3 4 5 67
1
V+ V-
1: Voltage supply
2: Display port
3: VGA socket
4: HDMI interface
5: Ethernet interface 2
6: Ethernet interface 1
7: USB ports
For special configurations observe the device's operating instructions.

QHA200
9
7 Set-up
When the operating voltage has been applied, the moneo|appliance functions according to the factory
settings. The LEDs show the status of the devices and of the interfaces.
7.1 Requirements
For the moneo|appliance set-up, the following components are required.
• Monitor with display port, VGA socket or HDMI interface.
• Keyboard with USB connection.
QHA200
moneo appliance
S/N:
1234567890
The serial number is provided on the product label on the side of the moneo|appliance housing.
7.2 Preparations
uConnect the monitor to the display port, VGA socket or HDMI interface.
uConnect the keyboard to one of the USB ports.
uConnect the mains plug.
uConnect the network cable.
1. ETH 1 (Ethernet interface 1) - sensor network
2. ETH 2 (Ethernet interface 2) - IT network
moneo|appliance
Ethernet interface Description Standard IP address Subnet mask
ETH 1 Sensor network 192.168.0.100 255.255.255.0
ETH 2 IT network DHCP DHCP
Once the operating voltage has been applied, the moneo|appliance can be switched on via the on/off
switch on the front of the device. Make sure that all cables have been connected according to the
description.
7.3 Set-up of moneo|appliance
The initial set-up of moneo|appliance is made via the connected keyboard and the monitor.
The different menu items in the appliance management system can be selected using the
keyboard. Example: The keyboard shortcut [C] opens [C) Configure the system].
uStart moneo|appliance.
wThe text "welcome to moneo appliance” is displayed on the monitor.
uEnter the login details and confirm with [Enter].
GB

QHA200
10
User name: administrator
password: <serial number of moneo|appliance>
wIf the login details are correct, the [Simple keyboard configuration menu] appears.
uSelect the corresponding keyboard layout and confirm by clicking on [OK].
uConfirm the successful change by clicking on [OK].
wPrompt to change the password appears.
uChange the password when signing in for the first time.
Password requirements:
• At least 8 characters
• Must contain:
– at least one upper case letter
– at least one lower case letter
– At least one number
– At least one special character
uRepeat the password and confirm by clicking on [OK].
uAfter assigning the new password, log in again with new login data.
wThe [Main menu] of moneo|appliance is displayed.
7.3.1 Adapting the hostname
The default hostname of moneo|appliance is:
moneo- <serial number of moneo|appliance>
uNote that the entry is case sensitive.
The hostname can be adapted when signing in for the first time or later by following the below
steps.
uOpen the [Main menu].
uSelect [C) Configure the system].
wThe [Configuration menu] opens.
uSelect [H) Change the hostname].
w[Hostname change] opens.
wThe current hostname is displayed in the field [Specify the new hostname].
uChange the hostname using the keyboard and select [<Ok>].
wThe hostname is saved and the interface [Hostname change] is closed.
uSelect [R) Return to the previous menu] to go back to the previous menu environment.
7.3.2 Adapting the IP address - Ethernet interface 2
uOpen the [Main menu].
uSelect [C) Configure the system].
wThe [Configuration menu] opens.
uSelect [N) Configure the network].
w[Network configuration] opens.
uSelect [I) IT network (ETH 2)].
uSelect [U) Use DHCP].
Tabla de contenidos
Otros manuales de Hardware de computadora de IFM
Manuales populares de Hardware de computadora de otras marcas

EMC2
EMC2 VNX Series Manual del propietario

Panasonic
Panasonic DV0PM20105 Manual de usuario

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manual de usuario

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manual de usuario

Raidon
Raidon iT2300 Manual de usuario

National Instruments
National Instruments PXI-8186 Manual de usuario












