700-678-03A
Create Buzz Zones
BUZZ ZONES give users warning of a zone being violated before
reporting an ALARM to the control room. The keypad will BEEP
for 30 seconds if a BUZZ zone is violated while the panel is STAY
ARMED. If a valid USER CODE is not entered in this period, an
alarm status will be reported to the control room.
Hold [4] until BEEP, ZONE NO [*]
Note: A zone cannot be a buzz zone and a stay zone
Working with Partitions
Partitions allow the alarm panel to create entirely separate
alarm areas, with dedicated USER CODES and programming.
Changing Partition View on the Keypad
Hold [MODE] till BEEP, then [1] [*] [PARTITION NUMBER] [*]
Arm a Specific Partition
1. Select Partition as above
2. Arm as per normal
Codes
Overview of Codes
The X-Series Panel supports multiple types of CODES, allowing
for flexibility in use:
The INSTALLER CODE and DOWNLOAD CODE are for the use
of professional installers only.
The single MASTER CODE enables its owner to program certain
user functions
USER CODES allow users to ARM / DISARM and carry out other
basic functionality on the system
Add User Code
Hold [*] till BEEP, then [MASTER CODE] [*] [0] [*] [NEW USER
CODE] [*], continue until all codes are entered then [#] to exit
Edit User Code
Hold [*] till BEEP, then [MASTER CODE] [*] [1] [*] [OLD USER
CODE] [*] [NEW USER CODE] [*]
Delete User code
Hold [*] till BEEP, then [MASTER CODE] [*] [2] [*] [USER
CODE] [*]
Important Information
-Alarm Panels are not infallible. The quality of installation
of your panel will determine its effectiveness.
-Do not access or program locations reserved for
professional installers as this might compromise your
installation
-Test the system regularly
Viewing Trouble Conditions
Flashing POWER LED indicates trouble condition. To identify
trouble condition:
Hold [7] till BEEP
Call an IDS-certified installer out to resolve the trouble
Remote Transmitters
Each remote transmitter is learnt to a user code and will inherit
those codes properties, i.e. arm/disarm, arm only, etc.
NOTE: When any button is held down for 3 seconds, the panel
goes into panic mode. Pressing the arm/disarm button does
NOT cancel the panic unless configured to do so, check with
your installer. The panic needs to be cancelled at the keypad.
Single Direction Remote Transmitter
The functions that can be assigned to a button are:
arm/disarm, stay, relay 1, and relay 2. Each button can be
assigned different functions, or no function. It cannot be
assigned both arm/disarm and stay. Different buttons can be
assigned the same function.
The figure shows the default button assignments
Note: A change will affect all remote transmitters
Bi-Directional Remote Transmitter
Each remote transmitter has five buttons to control the alarm
panel or query alarm status.
The default button assignments are indicated in the figure
below.
Note: Each Xwave2remote is a separate device and changes
only affect the remote you are currently working with.
Please see the relevant manuals to configure remote
transmitters.
Naming Zones
On an LCD keypad, zones can be named to give them more
meaning.
Hold [*] until BEEP; enter [MASTER CODE] [*] [3] [0] [*]
[ZONE No] [*] [*] [ZONE NAME] [*] [#]
NOTE:
-Pressing a key once will display the first letter on the key.
-Pressing a key twice will display the second letter on the
key etc. Numbers will be displayed once all the letters
listed on the key have been displayed.
-The [PANIC] and [MED] keys may be used to scroll right
or left through the name respectively. The [MODE] key is
used to toggle between upper and lower case.
-Pressing the [#] key will reset the zone name to [Zone
Number] if a character has been entered
NOTE: [0] [*] Copy All –this is used to update the zone names
to all keypads connected to the X64 Alarm Panel. This is used
when a keypad has been replaced or a new keypad is added.
LCD Keypad Language –Option 31
[*] [MASTER CODE] [*] [3] [1] [*] [Language] [*] [#]
Scroll via the [PANIC] or [Medical] keys press [*] to select.
Press the [#] key to exit the User Program Mode.
NOTE: This option is only available in version 2.02 LCD keypads
with X-Series firmware 2.32
Serial Code –Option 37
For communication to take place between serial device and X-
Series panel a six-digit code must be entered in option 37.
Note: This option can only be accessed via an LCD keypad.
LCD Keypad
[*] [MASTER CODE] [*] [3] [7] [*] [6 digit code] [*] [#]
1. Enter the User Program Mode as per steps 1 - 4 of section
User Program Mode
2. The LCD display reads ‘Option Menu’, ‘Add User Code’.
3. To select menu option 36, ‘Serial Code’, press the [3] [7]
keys followed by the [*] key or alternatively use the
[PANIC] or [MED] keys to scroll through the list of
programmable options to option 37.
4. Press the [*] key.
5. The LCD display reads ‘Serial Code’
6. Enter a random [6 digit code] that you want, followed by
the [*] key.
7. Press the [#] key to exit the User Program Mode.