Non Contact Stand Alone Coded Safety Switches
IDEM SAFETY SWITCHES Ltd., 2 Ormside Close, Hindley
Industrial Estate, Hindley Green, Wigan, WN2 4HR UK. Tel: +44 (0)1942 257070 Fax.: +44 (0)1942 257076
IDEM (USA) 4416
Technology Dri
ve, Fremont, CA 945
38 Tel:510-445-07
51 Fax:1866-431-
7064 email:
[email protected] Web: www.idemsafety.com
ISO13849-1 EN62061 EN60204-1
Safety Classification and Reliability Data:
Safety Output Maximum Rating
(*Max. current for QC is 2A)
Auxiliary Output Maximum Rating
Tolerance to Misalignment
5mm in any direction from 5mm setting gap
PSA High Specification Polyester
MSA Stainless Steel 316
PSA: IP67 MSA: IP69K/IP67
Flying Lead 250mm
M12 8 way Male Plug
(Pin view from switch)
Flying
Lead
Colours
Circuit
24Vdc +/- 10%
Safety Output 1 (Force guided relay)
AC15 240Vac 3A*
C13 24Vdc 3A*
Safety Output 1 (Force guided
AC15 240Vac 3A*
C13 24Vdc 3A*
1
d
June 2016
ION EXAMPLE: Switches in series PLe Cat.4
Two switches connected in series to
give dual circuit safety outputs to machine contactors.
Safety Circuit 1 (Black/White) utilises internally checked force guided relay contacts and is
connected in series with the corresponding Safety Circuit 2 (Yellow/Green) of the next
switch.
Allows minimal wiring and higher current switching to K1 and K2 contactors.
A manual start and contactor feedback check is achieved by connecting K1(Aux) and
K2(Aux) feedback contacts and momentary start button through the orange and brown
feedback check.
SAFETY PRECAUTIONS:
1. Installation and commissioning of the device must be performed only
by authorised ersonnel.
2. Observe the country specific regulations when installing the device.
3. The wiring of the device must comply with the instructions in this user
information - otherwise there is a risk that the safety function will be lost.
4. External fusing of the safety contacts (a slow blow or 6A quick action
must be provided).
5. All relevant safety regulations and standards are to be observed.
6. The overall concept of the control system in which the device is
incorporated must be validated by the user.
7. Failure to observe the safety regulations can result in death, serious
injury and serious damage.
Always use Safety Output 1.
To request this data sheet in other languages please contac
Um dieses
atenblatt in
eutscher Spr
ache wenden Sie sich bitt
e anfordern
inf[email protected]. Para solicitar esta hoja de datos en Español, por favor contacto con info@idemsafety.com.
EC/EU Declaration of Conformity
MANUFACTURER: IDEM SAFETY SWITCHES LIMITED
Hindley Industrial Estate, Hindley Green, Wigan, Lancashire WN 4HR, United Kingdom
THE LISTED DEVICES CONFORM TO THE ESSENTIAL HEALTH AND SAFET REQUIREMENTS OF THE FOLLOWING EUROPEAN DIRECTIVES
AND STANDARDS:
Machinery Directive ( 006/4 /EC)
EMC Directive ( 014/30/EU)
DEVICES: NON CONTACT SAFET SWITCHES:
PSA MSA Standalone Coded Safety Switches
STANDARDS (plus amendments):
EN 60947-5-3 013
EN ISO 13849-1: 008 + AC: 010 + AC: 013
M.Mohtasham Managing Director
1
st
May 2013
Characteristic Data according to IEC62061 (used as a sub system)
The calculation of the above values is based on the following assumptions:
Number of operating days per year: d
op
= 365d
Number of operating hours per day: h
op
= 24h
Number of operating cycles per day: n
cyc
= 1/d
B10
d
= 150,000 AC1 Load 3A
= 2,000,000 AC1 Load 0.5A
When the product is used deviant from these assumptions (different load,
operating frequency, etc.) the values have to be adjusted accordingly.
*Max. current for Quick Connect is 2A.
Information with regard to UL 508:
Type 1 Enclosures.
Maximum Temperature 45C
Maximum Output 24Vdc 3A
Use Class 2 Supply or equivalent