2
Classic SE RS - Users
e.
Flammable materials must not be placed in close proximity to
the appliance. Materials giving off flammable vapours must not
be stored in the same room as the appliance.
f. Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.
Minimum clearances
A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.
The minimum clearances given below MUST be complied with in
order to maintain the safe running of the boiler .
Above the boiler 100 mm (4")
At each side of the boiler 5 mm (1/4")
Underneath the boiler 100 mm (4")
In front of the boiler 75 mm (3")
To light the boiler. RefertoFrame1
If a programmer is fitted, refer to separate instructions for the
programmer before continuing.
1. CHECKTHATTHEELECTRICITYSUPPLYTOTHEBOILERISOFF.
2. Open the controls access door by hinging downwards.
3. Ensure that the gas inlet cock (C) is OPEN.
4. If an overheat thermostat is fitted press the overheat reset button
(D), located as shown in Frame 1.
5. SwitchONthe electricitysupplytothe boiler. Checkthatallexternal
controls, e.g. room thermostat etc., are ON.
6. Turn the boiler thermostat knob (B) to position 6. After about 15
seconds the boiler will light automatically - this can be viewed
through the sightglass (A).
Set the boiler thermostat to the desired position.
7. Close the controls access door.
INTRODUCTION
It is essential that the instructions in this booklet are
strictly followed, for safe and economic operation of
theboiler.
Current Gas Safety (Installation & Use)
Regulations or rules in force.
In your own interest, and that of safety, it is the law that
this boiler must be installed by a CORGI registered installer
orin IE a competent person, in accordancewith theabove
regulations.
Electricity Supply
This appliance must be efficiently earthed.
Supply: 230 V ~ 50 Hz. The fusing should be 3A.
Connection must be made in a way that allows complete
isolationof the electricalsupplysuch as adoublepole switch
having a 3mm (1/8") contact separation in both poles, or a
plugand socket, servingonly the boilerandsystem controls.
The means of isolation must be accessible to the user after
installation.
IMPORTANT NOTES
a.
This appliance must not be operated without the casing
correctly fitted and forming an adequate seal.
b.
If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.
c.
The ventilation provided for the boiler during installation MUST
NOT be blocked and a check should be made periodically
that the ventilation areas are free from any obstruction.
d.
If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer or in IE a competent person.
CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components.
Model GC Appliance No
Classic SE9 RS........................... 41 395 44
Classic SE12 RS .........................41 395 45
Classic SE15 RS ......................... 41 395 46
Classic SE18 RS .........................41 395 99
Classic SE RS (Natural Gas Models Only)