ICT PRT-IVO-IF Manual de usuario

PRT-IVO-IF
Protege Inovonics Wireless Receiver Module
Installation Manual

The specifications and descriptions of products and services contained in this document were correct at the time
of printing. Integrated Control Technology Limited reserves the right to change specifications or withdraw
products without notice. No part of this document may be reproduced, photocopied, or transmitted in any form or
by any means (electronic or mechanical), for any purpose, without the express written permission of Integrated
Control Technology Limited. Designed and manufactured by Integrated Control Technology Limited, Protege® and
the Protege® Logo are registered trademarks of Integrated Control Technology Limited. All other brand or product
names are trademarks or registered trademarks of their respective holders.
Copyright © Integrated Control Technology Limited 2003-2021. All rights reserved.
Last Published: 14-Sep-21 10:29 AM
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 2

Contents
Introduction 5
Installation Requirements 6
Grounding Requirements 7
Safety Grounding 7
Earth Ground Connection 7
Mounting the Module 9
Jumper Configuration 10
Configuring the Inovonics Frequency Jumper 10
Configuring the Inovonics EchoStream Select Jumper 11
Power Requirements 12
Encrypted Module Network 13
End of Line (EOL) Resistors 13
Relay Output 14
Ethernet 10/100 Network Connection 15
Defaulting the IP Address 16
Module Configuration 17
Logging in for the First Time 17
Configuration 17
Device Information 18
User Management 18
Configuring Protege GX and Protege WX 19
Prerequisites for Protege GX and Protege WX 19
Adding the Module in Protege GX 19
Adding the Module in Protege WX 19
Linking Inputs to Inovonics Devices 20
Inputs Table (PRT-IVO-IF) 20
Inputs Table (PRT-IVO-IF-EU) 22
Input States 22
Trouble Inputs 22
Battery Events 23
Access Control 23
Creating a Credential Type 23
Creating a Door Type and Linking to Credential Type and Door 23
Linking an Inovonics Module to a Door 24
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 3

Creating an AccessLevel 24
Linking to a User 24
Error Code Indication 25
Error Code Display 25
Mechanical Diagram 26
Mechanical Layout 27
Technical Specifications 28
New Zealand and Australia 29
European Standards 30
FCC Compliance Statements 31
Industry Canada Statement 32
Disclaimer and Warranty 33
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 4

Introduction
The Protege Inovonics receiver module is designed to facilitate integration between Protege systems and wireless
Inovonics devices. It works with the Inovonics EN4200 EchoStream receiver to translate incoming Inovonics
signals so they are understood by Protege controllers. The module can link up to 255 Inovonics wireless devices to
each EchoStream receiver.
The receiver module is available in two unit types suitable for the following frequencies:
⦁PRT-IVO-IF: for use in the US (902-928 MHz), Australia (915-928 MHz), and New Zealand (922-928 MHz)
⦁PRT-IVO-IF-EU: for use in the EU region (868-870 MHz)
Note: the Inovonics receiver module integrates with both Protege GX and Protege WX systems. This manual
provides integration instructions for both.
Key features of the Protege Inovonics Wireless Receiver Module include:
⦁The ability to connect to Protege systems via RS-485 network or ethernet.
⦁A web interface for easy network setup and boot mode for firmware updates.
⦁Firmware upgrade via Trivial File Transfer Protocol (TFTP).
⦁The linking of Inovonics wireless devices, such as PIRs and remotes, to Protege inputs.
⦁The linking of Inovonics remotes to Protege users for access control.
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 5

Installation Requirements
This equipment is to be installed in accordance with:
⦁The product installation instructions
⦁AS/NZS 2201.1 Intruder Alarm Systems
⦁The Local Authority Having Jurisdiction (AHJ)
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 6

Grounding Requirements
An effectively grounded product is one that is intentionally connected to earth ground through a ground
connection or connections of sufficiently low impedance and having sufficient current-carrying capacity to
prevent elevated voltages which may result in undue hazard to connected equipment or to persons.
Grounding of the Protege system is done for three basic reasons:
1. Safety
2. Component protection
3. Noise reduction
Safety Grounding
The object of safety grounding is to ensure that all metalwork is at the same ground (or earth) potential.
Impedance between the Protege system and the building scheme ground must conform to the requirements of
national and local industrial safety regulations or electrical codes. These will vary based on country, type of
distribution system and other factors. The integrity of all ground connections should be checked periodically.
General safety dictates that all metal parts are connected to earth with separate copper wire or wires of the
appropriate gauge.
Earth Ground Connection
The DIN rail enclosure and the DIN rail modules must be grounded to a suitable single-point earth ground
connection in the installation. A minimum 14AWG solid copper wire (or thicker, in accordance with local
authorities) shall be used from the Protege system's earth connection points.
The DIN rail enclosure includes an earth ground single-point link connection via the metallic enclosure. This single-
point link is the Protege system's earth ground. All modules that have earth ground connections and that are
installed in the same enclosure shall be connected to this single point. A single-point earth ground connection
avoids the creation of ground loops in the system and provides a single reference point to earth ground.
Reader Expander
Input Expander
Output Expander
Controller
Dialer’s Earth
Ground Connection
Power Supply
V-
DIN Rail Ground Connections (one or more cabinets installed in the same room)
DIN Rail Enclosure Additional DIN Rail Enclosure(s)
Module Network
(RS-485 N+, N-, NA, NB)
AC Mains Wiring
Earth Ground
Link Connection
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 7

Sector or Building #2Sector or Building #1 Sector or Building #3
Input Expander
Input Expander
Input Expander
Reader Expander
Input Expander
Output Expander
Power Supply
Controller
Dialer’s Earth
Ground Connection
V-
Earth Ground
Link Connection
DIN Rail Enclosure DIN Rail Enclosure DIN Rail Enclosure
Module Network (RS-485 N+, N-, NA and NB)
DIN Rail Ground Connections (multiple cabinets in different rooms, sectors, or buildings)
Note that the DIN rail enclosure earth terminal is connected to the power supply V- terminal.
There must be only one single earth grounding point per system.
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 8

Mounting the Module
The receiver module should be mounted in a location away from metal objects (such as duct work, wire mesh
screens, and boxes) as they will reduce RF range.
For best results, mount transmitters and repeaters so they achieve line of sight with the repeaters and/or the
receiver. This usually means they should be mounted as high as possible.
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 9

Jumper Configuration
Configuring the Inovonics Frequency Jumper
This section applies only to the NA / AUS / NZ variant of the Inovonics receiver module (PRT-IVO-IF).
The Inovonics EchoStream Receiver can use a range of radio frequencies and must be configured based on your
geographic area using the frequency jumper.
The frequency jumper is labeled NZ AUS and is located on the Inovonics side of the board.
Frequency Jumper
N+ N- NA NB NC COM NO
NZ AUS
NZ AUS
If using the device in North America, ensure that the frequency jumper is removed from the pins:
NZ AUS
If using the device in New Zealand, place the jumper on the left two pins, marked NZ, to set the frequency range to
921-928 MHz:
NZ AUS
If using the device in Australia, place the jumper on the right two pins, marked AUS, to set the frequency range to
915-928 MHz:
NZ AUS
If the device is powered on, remove and restore the power source to apply the change.
PRT-IVO-IF | Protege Inovonics Wireless Receiver Module | Installation Manual 10
Tabla de contenidos
Manuales populares de Módulo inalámbrico de otras marcas

Cooper Wiring Devices
Cooper Wiring Devices ESPIRE RF RFAPM Manual de usuario

Yuga
Yuga CLM920 Manual de usuario

Waldmann
Waldmann TALK Bluetooth Manual de usuario

Telit Wireless Solutions
Telit Wireless Solutions UC864-G Manual de instalación

Ebyte
Ebyte E07-900M10S Manual de usuario

Quectel
Quectel SC690A Series Suplemento

Panasonic
Panasonic INDUSTRY PAN9028 Guía de configuración rápida

Ebyte
Ebyte E70-433NW30S Manual de usuario

LongSung Technology
LongSung Technology U9507E Manual de usuario

Wistron NeWeb
Wistron NeWeb DNUR-S2 Manual de usuario

Ebyte
Ebyte E49-400M20S4 Manual de usuario

RF-Star
RF-Star SimpleLink RF-BM-2652P1 CC2652P Manual de usuario