Hy-Gain HG-54HD Manual de usuario

HG-54HD 54-Foot Self-
Supporting Tower


Overall View of HG-54HD Tower
-ii-

WARNING
Installation of this product near power lines
is dangerous. For your safety, FOLLOW
THE INSTRUCTIONS.
NOTE: If you are installing the Hy-Gain HDR-
300 Rotator on your tower, you will not be able
to nest the tower completely.
UNPACKING AND UNCRATING
GENERAL DESCRIPTION
This model is a 54-foot self-supporting tower
designed to support 16.0 square feet of antenna
area with winds up to 60 mph. This all steel
tower has a guide system that allows the
tubing to be open at each end insuring
complete galvanizing and total moisture
draina
g
e.
The tower is extended from its nested position
by manual crank. A thrust bearing can be
bolted to the top section allowing a 2"
diameter mast.
Be sure to check your tower for any freight
damage or missing parts. If you find damage,
notify the trucking line that delivered the
equipment immediately and advise Hy-Gain of
the damage. Send a copy of the freight damage
claim to:
Hy-Gain
Telex Communications, Inc.
8601 East Cornhusker Highway
P.O. Box 5579
Lincoln, Nebraska 68505-5579
EQUIPMENT
The HG-54HD tower is supplied complete, in-
cluding reinforcing steel and base mount. The
tower corresponds to the drawings contained
in this manual. Refer to the Parts List section
for a complete breakdown of parts.
The Parts List shows the standard commercial
packaging. Any changes or modifications, if
any, which may be incorporated as the result
of special contractual agreements are covered
under
EQUIPMENT REQUIRED BUT
NOT SUPPLIED


GENERAL SAFETY
Hundreds of people are killed each year
because they don't use common sense when
they install their towers or antennas. It
happens more often then you realize. Someone
falls off of a roof or gets electrocuted by
touching a power line with an antenna tower
or metal ladder.
There is no such thing as a good tower site if it
is near electrical power lines. Unfortunately,
most tower systems, and in many cases, the
ladders used during an installation, are metal.
If any metal tower part or ladder touches a
power line, it completes an electrical path
from the power line through the metal tower
and the installer (YOU!).
Don't overload. The design load limit is
16 square feet of antenna on a 2 foot mast
for winds u
p
to 60 m
p
h.
DO'S
Do install the tower away from power
lines. Check the distance to the power
lines before you start installing - we
recommend you stay a minimum of twice
the maximum length of the tower
assembly away from all power lines.
Do install the tower on a calm day and
assure yourself of having plenty of
da
y
li
g
ht to com
p
lete installation.
Do stay clear if the tower starts to fall or
come in contact with
p
ower lines.
Do call the power company to remove
fallen towers from power lines or to help
pick out a safe antenna site.
Do crank tower down to retracted position
when winds are anticipated to exceed 50
mph.
DON'TS
Don't install any tower near power lines.
Don't install a tower on a windy day.
Don't try to do the job by yourself.
Don't try to catch the tower if it starts to fall.
Don't try to remove any metal objects from
the power lines.
Don't be afraid to call the power company
for advice when picking a tower site or
removing a fallen tower from the power
lines
Don't remove winch handle; use safety
chain with lock to secure.
Don't climb tower, use separate ladder or
lower tower with gin pole for antenna
rotator servicin
g
.
If someone is accidentally electrocuted, don't
touch him or the tower if he is still in contact
with the tower or downed power lines. Use a
dry stick, like a broom handle or wooden
ladder, etc. and in one sweep, push the person
free from the tower or knock the wire away
and off the victim. Have someone call an
ambulance and the power company.
SITE SELECTION
The tower requires a concrete base ap-
proximately 42" x 42" x 72" (1067 mm x 1067
mm x 1829 mm) deep. Among the factors to be
evaluated in selecting a tower site are the types
of earth at the installation site and the
nearness of power lines or overhanging tree
limbs. Soil conditions around the tower
foundation should allow access to the tower
during all weather conditions.


Good planning is a key to a successful and safe
tower installation. If you're not sure about a
careful, safe installation, don't try to do it your-
self. Call for professional help (Yellow Pages
under Towers or
y
our local
p
ower com
p
an
y)
.
During shipment or
may have resulted to
foundation assembl
y
.
while in storage, damage
the tabs on the tower base
The tower should be as close as possible to its
related equipment. Determine the best possible
site while thinking about power lines, but also
think about overhanging tree limbs that may be
blown into the tower durin
g
hi
g
h winds.
Dig a hole 42" (1067 mm) square by 72" (1829
mm
)
dee
p
as shown in Fi
g
ure 3.
Before installation of this tower, check proper
alignment of the tabs. To do this, set the tower
horizontally on two supports. Attach the base
foundation assembly to the tower using the
three-quarter inch (3/4") hardware, as shown
below.
If the tabs on the base foundation assembly are
out of ali
g
nment
,
use a lar
g
e hammer to reali
g
n. Construct a wooden frame around the hole to
support the base foundation assembly as shown
in Fi
g
ure 4.

TO-0130-A-002
In the U.S.A. the dimensions of lumber are
listed, and referred to, as the size after it is
rough-cut at the sawmill, prior to being dried,
planed and sold on the market. A sample
would be the two by four (2" x 4"), which
after being dried and planed will measure
11/2" x 3 1/2" (38 x 89 mm), or a two by six
(2" x 6") which will measure 11/2" x 5 1/2"
Orient your tower base in the direction your
tower will be raised. The two parallel ears of
the base foundation assembly will be in the
hinged side.
TO -130 -1 -B -007 The tabs on the tower base foundation
assembly may have been knocked out of
ali
g
nment durin
g
shi
p
ment or while in stora
g
e.

TO
-
130
-
1
-
B
-
003
In order to support the base foundation assemb- Attach the base foundation assembly to the ly
during concrete pouring, three wood supports wood supports using 3/4" bolts (not supplied).
are needed as shown in Figure 7.
Using a carpenter's level, check all points to Drill a 3/4" hole in each wood support in line with
make sure base foundation assembly is level. the lower holes in the base foundation assembly as
shown in Figure 7.
FORM FOR CONCRETE BASE '
APPROXIMATELY Sy' 033mm)
OF ASSEMBLY EAR BURIED IN CONCRETE
TO
-
130
-
1
-
8
-
00
•
BASE FOUNDATION STRUCTURE ASSEMBLY EAR
(TYPICAL THREE PLACES)
2"x4' (38.90--Octu01)WOOD SUPPORT TO WHICH
ASSEMBLY EARS ARE BOLTED
(TYPICAL THREE PLACES)
'A' NUT
Tabla de contenidos