HMW LoLog 450 Series Manual rápido

LoLog 450/500 series data logger
Basic User Manual for
Installation and use
LoLog LL / 500 / Vista LoLog 450
Version 1.2
Warning: This manual contains important safety and operating information.
Please read, understand and follow the instructions in the manual.

1
TABLE OF CONTENTS
INTRODUCTION 3
UNPACKING 3
INSTALLING THE SOFTWARE 3
FIRST TIME RUN OF RADWIN 7
Creating your first Database 7
Setting up the communications cable 10
PROGRAMMING YOUR FIRST LOGGER 14
Using the Configure Logger wizard 14
DOWNLOADING DATA FROM THE LOGGER AND VIEWING RESULTS 22
Download Data Wizard 22
Graph and Data Table Manipulation 24
Selecting the Input Channel Data to be viewed 25
Changing the Information in the Data Table 25
Changing the Graph Style 26
LOLOG VISTA DISPLAY OPTIONS 27
Analogue Channels 29
Digital Channels 31
Meter Reading 31
MIN/MAX Value 32
FLOW INPUT 33
MILLIAMP INPUT 33
TECHNICAL SPECS 35
LoLog LL / 500 / Vista Series 35
LoLog 450 Series 36

3
Introduction
Thank you for choosing an HWM data logger(s), we trust it will provide you with many years
of service.
The individual configuration of your logger(s) may differ slightly from the detailed
descriptions that follow, but any additional setup information that you need, can easily be
obtained from our customer support team.
Unpacking
As you unpack your new logger, please confirm that you have the following parts required
to install the equipment. If there are any omissions, please contact our sales team to rectify
or supply the missing parts.
LoLog data logger
Radwin Software CD-ROM (also available at http://www.hwmglobal.com)
IR Reader (optional –available in serial or USB types)
Connection cables (optional)
Connection hose for a pressure logger (optional)
Please dispose of your waste packaging responsibly.
Before proceeding to site for physical installation, please take the time to configure your
logger in an office environment. Most settings can be configured before visiting site and this
will save time at the point of install, especially if the weather is bad.
You will need to have:-
A PC with Windows 7/8 installed (Radwin also supports Windows XP & Vista)
A USB to Serial adaptor (if required to use with serial IR reader).
A description and reference number for the installation site:
The reference number is split into a Zone and Location format to allow for grouping
of individual “Locations” into larger regions or “Zones”.
The format of the number is configured during the initial installation of the software
but essentially is a 7 character code, e.g. AB123CD
Installing the software
1. Insert the CD-ROM supplied into your CD drive.
(If your PC does not have a CD drive, then either copy the files from the CD-ROM
onto a memory stick, or download and run the Radwin installation file from the HWM
website at http://www.hwmglobal.com)
2. When prompted:-

4
Click <<Run Installer>>
If the prompt does not appear automatically, please open
the CR-ROM folder using Windows explorer (My Computer).
Double Click the CD-ROM icon to run the installer
3. Now click <<Radwin>> from the Installer
Click to install Radwin software.
Note Radwin Lite is only for specialist use.
The I/R Driver is normally installed automatically, however, in case it does not in
step 0 below, please click the <<USB I/R Reader Driver>> after the main installation
is complete.
4. When prompted by the InstallShield Wizard to install:

5
Click <<Next>>
5. Read and agree the terms of the Licence agreement to continue:
Click the <<I accept…>> radio
button, then Click <<Next>>
6. Choose the Destination
folder you wish to install to by clicking
<<Change>>
or to accept the default installation
(recommended) click <<Next>>

6
Note: Ensure that you choose a folder that you have read/write access to. Check with
your IT team if you are not sure.
7. The installation process now has all the information it needs to proceed so click
<<Install>> to continue
Wait while the installation completes…
and the I/R Driver installs…
8. Finally click <<Finish>> to close the InstallShield Wizard.

7
9. Then click <<Exit>> to close the Installer.
10.If you have installed from a downloaded file instead of the CD you will see the extra
window below.
The Installation process has now finished so click <<OK>> to confirm.
First time run of Radwin
Once you have installed Radwin you need to make some initial setup choices and
configurations.
Creating your first Database
1. From the start menu, click <<All programs>> and find
the program group “Radlog for Windows”
2. Click <<Radlog for Windows>> to expand the group
and then click <<Radcom View>>
You may wish to “Pin” the program to your taskbar
for convenience. To do this, right click on the
Radcom View icon and select “Pin to Taskbar” from
the pop up menu.
The program can now be conveniently started from
the taskbar.
3. After the program starts you will be automatically prompted to set up a new database
path
This is for local storageof configuration information and any data that you may directly
download from the logger or from DataGate™ after site installation.

8

9
A note about Logger Identity Selection Method:-
A logger is identified with a single 7 digit reference ID.
If you select Single Identity from the menu then you can
use the full 7 digits how you like.
E.g. account no, customer number, etc.
However, when installing a larger fleet of loggers, Radwin allows you to group
individual logger Locations into larger Zones. This allows for geographic regions
(Zones) to be easily indexed where large fleets are involved.
So, Locations refer to loggers
Zones contain Locations (loggers)
Many Zones may be created
Each Zone may contain many Locations (loggers)
For example, split a town up into Zones then split the Zones up into Locations and
deploy loggers within each Zone.
If you choose this (default) option you will be prompted (later on) to decide how the 7
digits are allocated. E.g. ZZ/LLLLL means you can have up to 99 zones with 99,999
loggers in each zone, or ZZZ/LLLL gives 999 zones with 9,999 loggers in each and
so on.
In this way you can develop an indexing method to allow you to quickly find sites you
wish to examine.
4. From the Logger Identity Selection Method,
choose the option as described above.
If you wish to change to location of the folder where the
database is stored, click <<Browse…>>
Then navigate to the desired folder and click <<Open>> to choose the folder.
When prompted below click <<Yes>> to confirm the folder choice.
5. Now click <<OK>> to create the database.
If you chose Zones and Locations in step 4, chose your
format for the ID number. The default is the UK postcode
format, e.g. AB12 3CD
Then click <<OK>> to continue.
Note: The Database format CANNOT be changed from this point. If you need to
change it later you will need to delete the \DATA folder and start again.