HMS Networks Anybus Guía del usuario

Anybus®Managed Layer 2 PoE Switch
STARTUP GUIDE
SP2978
Version 1.1
Publicaon date 2022-05-09
ENGLISH

Important User Informaon
Disclaimer
The informaon in this document is for informaonal purposes only. Please inform
HMS Networks of any inaccuracies or omissions found in this document. HMS Networks
disclaims any responsibility or liability for any errors that may appear in this document.
HMS Networks reserves the right to modify its products in line with its policy of
connuous product development. The informaon in this document shall therefore not
be construed as a commitment on the part of HMS Networks and is subject to change
without noce. HMS Networks makes no commitment to update or keep current the
informaon in this document.
The data, examples and illustraons found in this document are included for illustrave
purposes and are only intended to help improve understanding of the funconality and
handling of the product. In view of the wide range of possible applicaons of the product,
and because of the many variables and requirements associated with any parcular
implementaon, HMS Networks cannot assume responsibility or liability for actual use
based on the data, examples or illustraons included in this document nor for any
damages incurred during installaon of the product. Those responsible for the use of
the product must acquire sucient knowledge in order to ensure that the product is
used correctly in their specic applicaon and that the applicaon meets all performance
and safety requirements including any applicable laws, regulaons, codes and standards.
Further, HMS Networks will under no circumstances assume liability or responsibility for
any problems that may arise as a result from the use of undocumented features or
funconal side eects found outside the documented scope of the product. The eects
caused by any direct or indirect use of such aspects of the product are undened and may
include e.g. compability issues and stability issues.
Copyright © 2022 HMS Networks
Contact Informaon
Postal address:
Box 4126
300 04 Halmstad, Sweden
E-Mail: inf[email protected]

1. Preface
1.1. About This Document
This document describes how to install Anybus® Managed Layer 2 PoE Switch.
For addional documentaon and soware downloads, FAQs, troubleshoong guides and
technical support, please visit www.anybus.com/support.
1.2. Document Convenons
Safety Symbols
DANGER
Instrucons that must be followed to avoid an imminently hazardous
situaon which, if not avoided, will result in death or serious injury.
WARNING
Instrucons that must be followed to avoid a potenal hazardous situaon
that, if not avoided, could result in death or serious injury.
CAUTION
Instrucon that must be followed to avoid a potenal hazardous situaon
that, if not avoided, could result in minor or moderate injury.
IMPORTANT
Instrucon that must be followed to avoid a risk of reduced funconality
and/or damage to the equipment, or to avoid a network security risk.
Preface Anybus® Managed Layer 2 PoE Switch
SP2978 Version 1.1 Page 1 of 16

Informaon Symbols
NOTE
Addional informaon which may facilitate installaon and/or operaon.
TIP
Helpful advice and suggesons.
1.3. Trademarks
Anybus® is a registered trademark of HMS Networks.
All other trademarks are the property of their respecve holders.
Anybus® Managed Layer 2 PoE Switch Trademarks
Page 2 of 16 SP2978 Version 1.1

2. Safety
2.1. Intended Use
The intended use of this equipment is as a communicaon interface and gateway. The
equipment receives and transmits data on various physical levels and connecon types.
If this equipment is used in a manner not specied by the manufacturer, the protecon
provided by the equipment may be impaired.
2.2. General Safety
CAUTION
Ensure that the power supply is turned o before connecng it to the
equipment.
CAUTION
Connecng power with reverse polarity or using the wrong type of power
supply may damage the equipment. Make sure that the power supply is
connected correctly and of the recommended type.
CAUTION
This equipment contains parts that can be damaged by electrostac
discharge (ESD). Use ESD prevenon measures to avoid damage.
CAUTION
To avoid system damage, the equipment should be connected to ground.
Safety Anybus® Managed Layer 2 PoE Switch
SP2978 Version 1.1 Page 3 of 16

CAUTION
This equipment is recommended for use in both industrial and domesc
environments. For industrial environments it is mandatory to use the
funconal earth connecon to comply with immunity requirements. For
domesc environments the funconal earth must be used if a shielded
Ethernet cable is used, in order to meet emission requirements.
CAUTION
This equipment emits RF energy in the ISM (Industrial, Scienc, Medical)
band. Make sure that all medical devices used in proximity to this
equipment meet appropriate suscepbility specicaons for this type of
RF energy.
CAUTION
Minimum temperature rang of the cable to be connected to the eld
wiring terminals, 90 °C.
CAUTION
When wiring low voltage input for Managed L2 PoE Switch output, it
may generate higher current. The wiring cable must meet or exceed the
AWG16 specicaon.
CAUTION
Hot surface. Do not touch. When the switch is in operaon, the metal
surface temperature becomes very hot.
Anybus® Managed Layer 2 PoE Switch General Safety
Page 4 of 16 SP2978 Version 1.1

IMPORTANT
Installaon, conguraon, pung into service, use and maintenance must
be performed by personnel authorized by the manufacturer.
IMPORTANT
Using the wrong type of power supply can damage the equipment. Ensure
that the power supply is connected properly and of the recommended
type.
General Safety Anybus® Managed Layer 2 PoE Switch
SP2978 Version 1.1 Page 5 of 16

3. Cyber Security
IMPORTANT
The equipment is intended to be used in a restricted access locaon.
Access should only be given to skilled person or instructed person who has
been instructed in the operaon of the equipment.
IMPORTANT
The switch must be installed at Restricted Access Locaons, such as
control room/control cabinet. The switch is designed for in building
installaon only and is not intended to be connected to exposed (outside
plant) networks.
Anybus® Managed Layer 2 PoE Switch Cyber Security
Page 6 of 16 SP2978 Version 1.1

4. Preparaon
4.1. Package Checklist
Table 1. Box Contents
Item Pieces
Product unit 1
Startup Guide 1
Safety and Regulatory Compliance Informaon 1
4.2. Support and Resources
For addional documentaon and soware downloads, FAQs, troubleshoong guides and
technical support, please visit www.anybus.com/support.
NOTE
Have the product arcle number available, to search for the specic
product page. You nd the product arcle number on the product cover.
Preparaon Anybus® Managed Layer 2 PoE Switch
SP2978 Version 1.1 Page 7 of 16

5. Installaon
5.1. DIN Rail Mounng
NOTE
Mount the switch on a DIN rail in accordance with the EN 50022 standard.
NOTE
Mount the switch at a height of ≤2 m.
Mount the switch on a DIN rail:
1. Insert the upper end of the DIN rail clip into the DIN rail.
2. Push the boom of the DIN rail clip into the DIN rail.
Anybus® Managed Layer 2 PoE Switch Installaon
Page 8 of 16 SP2978 Version 1.1