§2. Wireless Connection
Note: One wireless indicator only can connect with one wireless weighing transmitter, and both
wireless communication frequencies should be same. Wireless communication frequencies are set in
factory and user cannot change. Regular wireless communication frequency is 430MHz
If user wants to use two or more than two set of wireless weighing indicator and wireless weighing
transmitter, wireless communication frequencies must be different. Please let salesman know and
wireless communication frequencies will be set in factory.
1. Connect wireless weighing transmitter with load cell.
2. Switch on wireless weighing transmitter until the wireless function works.
3. Switch on wireless weighing indicator and calibrate.
4. In configuration mode, set “Con” to Con=78.
5. When indicator wireless lamp flashes, wireless weighing transmitter and wireless weighing indicator
are connecting.
6. Then, to calibrate wireless weighing indicator and configure.
7. RS-232C D-B 9: Pin 3 Output (TXD) and Pin 5 Signal Ground (GND)
8. RS232 interface is continuous data output
9. Address = 0continuous data output, form is =,X1,X2,X3,X4,X5,X6, while X1,X2,X3,X4,X5,X6 is
data,= is break. E.g.: if weigh is 123.45kg, data will be = 54.321 =54.321
Address = 99continuous data output, form is =,X6,X5,X4,X3,X2,X1, while X6,X5,X4,X3,X2,X1 is
data,= is break. E.g.: if weigh 123.45kg, data will be = 123.45= 123.45