the set temperature. This value can be set with a 0.5°
interval.
This prevents the controller switching the relay on/o
when the temperature oscillates around the set sensor
temperature.
Default value is 0.5°C.
Use or to set value
Press to conrm
P-12 Over current alarm
Congure the alarm or turning function on/o
Use or to navigate
• AL.y - Enable
• AL.n - Disable
Press to conrm
If the load is above 16.4A, the display will show alarm
“Warn” and “Cu”, the thermostat will sound and alarm, the
relay will be forced to turn o, and the device will report an
alarm every minute until the alarm is cancelled.
Reset the alarm by pressing and holding ON/OFF button
for at least 5 seconds, or cancel it through the app.
Default value is Enabled.
P-13 Button vibration settings
Adjust the Button vibration level
Use or to navigate
• Select vl.0 - OFF (default)
• Select vl.1 - Low
• Select vl.2 - Medium
• Select vl.3 - High
Press to conrm
P-14 Open window detection
Set the threshold value for “open-window” detection
Use or to select value between 1 - 10
To disable the open-window detection function select “0”
If the room sensor temp. decreases more than the set
value within 10 minutes, the icon will ash slowly,
and the device will be temporarily turned o. If anti-freeze
mode is enabled the device will activate anti-freeze, if anti-
freeze thresholds are crossed.
The “open-window” mode will be reset if the room sensor
temperature increases by 2°C within 10 minutes, if the
power of the device is reset, or if the operation mode is
changed. The icon will then disappear and the device will
indicate a return to normal operating mode.