Heaven Fresh HF 710 Manual de usuario

©2014, HFEF-CAN | US | FR | UK | HF -12/14
INSTRUCTION MANUAL
MANUEL D’UTILISATION
HEAVEN FRESH
3 Year Limited Warranty | 3 Ans De Garantie Limitée
HF 710 DIGITAL ULTRASONIC COOL & WARM MIST
HUMIDIFIER with Aroma Function
HUMIDIFICATEUR ULTRASONIQUE NUMÉRIQUE
À BRUME TIÈDE ET FRAÎCHE avec Fonction d'arômes HF 710

Thank you for purchasing the innovative Heaven Fresh HF 710 Cool Mist Ultrasonic
Humidifier. We wish you many years of healthy indoor air with this efficient and effective
product.
Ensure that all safety precautions are followed when using this electrical appliance for the
proper operation of the device. These instructions describe the safety precautions to be
observed during operation. They are designed to prevent injuries or damage to this device.
SAFEFY PRECAUTIONS
Check the household voltage to ensure it matches the units rated specification
before operating.
Children should be supervised to ensure that they do not play with the appliance.
Do not allow children to play with any product packaging, such as plastic bags.
To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator,
stoves, or heaters.
DO NOT place humidifier near heat sources such as stoves, radiators, and heaters. Do
locate your humidifier on an inside wall near an electrical outlet. The humidifier should be
at least 10cm away from the wall for best results.
Do not attempt to refill humidifier without first unplugging the unit from its electrical outlet.
Never place anything over moisture outlet when the unit is running.
DO NOT operate any appliance with a damaged cord or plug, after the appliance
malfunctions, or if it has been dropped or damaged in any manner. Return appliance to
manufacturer for examination, electrical or mechanical adjustment, or repair.
Use appliance only for intended household use.DO NOT use outdoors.
Always place humidifier on a firm, flat, level surface at least 60cm away from the floor.
DO NOT allow the moisture outlet to directly face the wall.
Humidifier should be unplugged when not in use.
NEVER tilt, move, or attempt to empty unit while it is operating.
Shut off and unplug before removing the water tank and moving the unit.
DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit.
Doing so will void your warranty. The inside of the unit contains no user serviceable
parts. All servicing should be performed by qualified personnel only.
Do not plug in the cord with wet hands: electric shock could result.
HF 710

NEVER use detergents, gasoline, glass cleaner, furniture polish, and paint thinner, or
other household solvents to clean any part of the humidifier.
Do not pour water in any openings other than the water tank.
Excessive humidity in a room can cause water condensation on windows and some
furniture. If this happens, turn the humidifier OFF.
Never place housing under water flow or immerse in liquids.
IMPORTANT
The transducer, filter and basin should be cleaned regularly. Please see the reference on
page 08 and 09.
WHY HUMIDIFY THE AIR?
When the air is dry, especially in the winter months, it can become unpleasant and even
unhealthy, leading to increased levels of static electricity, dry skin, cracked lips and even
noise bleeds. Optimal humidity is between 45 to 55% relative humidity. During the winter
months though, relative humidity in the average home can drop to below 20%.
Low humidity can lead to a variety of conditions that cause ill health. Dust particles, bacteria,
viruses, dust mite feces that are normally trapped by the moist nasal membrane lining in the
nose can more easily get into the lungs when the air is dryer and thus reduce the body's
natural defense mechanism. These invaders overload the immune system and irritate the
mucous membranes resulting in more coughing and susceptibility to disease.
The HF 710 is an ideal ultrasonic humidifier for homes, apartments, offices and anywhere
there is low humidity. Ultrasonic water vapour is highly beneficial to individuals. Their biggest
advantage is high performance combined with low energy consumption.
WHY HUMIDIFY THE AIR?
Ultrasonic Humidifiers use ultrasonic high frequency oscillation to break up water into tiny
water particles about 1.5 microns in diameter. The ventilation system blows out the water
particles into the dry air where they evaporate and create the required humidity level. The
water particles appear as a steady stream of mist or fog as they travel up and out of the
machine.
HF 710

HF 710 FEATURES AND BENEFITS
Efficient and Effective
Variable spray mist control for use with small, medium or large rooms.
Large capacity water tank (6L/1.5 gallons) refills with normal tap water.
High moisture output can quickly humidify a room up to 60 m² (650ft²).
Low water indicator notifies you when to refill the tank.
Advanced Technology
Advanced digital technology can produce either cold or warm mist.
Added benefit of Aroma function for increases therapeutic capabilities.
Auto Hygrostat sensor automatically regulates mist output according to desired
humidity level.
Safely and automatically shuts off when it runs out of water.
Hassle Free Operation
Simple, easy-to-use, one-touch timer control for up to 12 hours of operation.
Virtually silent operation with advanced ultrasonic technology ensures a quiet and
restful sleep.
Low Operating costs
Low energy consumption - can save 85-90% of electricity costs compared to a normal
steam humidifier.
Consumes less power than a 40 watt light bulb (on cool mist).
HF 710

COMPONENTS
Nozzle
Handle cap
Handle
Water tank
Water level senor
Air flue
Mist
tube
Water
tank cover
Transducer
Heating
element
Power cord
Aroma box
LED display
On/off
button
Mist level
button
Timber button
Set humidity
button
Heating button
Auto button
White Dust & Anti-Microbial Filter:
The humidifier is equipped with a water filter that contributes in particular to treating the
calcium content in the water. To install the filter please attach it to the internal wall of water
filter as shown below and check whether the silicon ring is positioned properly. Close the
cover by turning the latter in a clockwise direction as illustrated in drawing 3.
HF 710

PRE-OPERATING INSTRUCTIONS
Before getting started, please remove the HF710 from its box and allow it to become
accustomed to the room temperature for at least 30 minutes especially if the machine is cold
from the outside air. The HF 710 is designed to operate at temperatures between 5-40 ºC
(41-104 F) and relative humidity of less than 80%.
Water Tank Filling
Get the water tank out of the machine, unscrew the lid and fill the tank with water, then screw
the lid well. Put the water tank on the machine body steadily.
NOTE: Do not add water directly to water sink, always add water into water tank.
LCD Display
%
12 3
+1hr. +2hr. +4hr. +5hr.
5
4+1+ hr. 2hr. + hr. + hr. Timer icon
12 3 Cool mist humidifying level icon
%Humidity icon
Waterless icon
Auto function icon
Low warm mist level icon
Medium warm mist level icon
High warm mist level icon
High temperature warning icon
When the device is broken down or is not properly used,
the PTC heating element or the atomizer may be overheated,
the device will stop working automatically with the high
temp. icon turned ON.
Set Humidity status icon
HF 710

OPERATING INSTRUCTIONS
Plug in the power, and then press the on/off switch to turn ON the humdidifier.
Buttons instruction
HF 710
Timer: Timer can be set from 1-12 hours
On/off : Press it once, the machine will start working with LCD display on.
Press this button again and the machine will stop working and will go to the standby mode.
AUTO: Pressing this button will move the machine into automatic control mode.
The device will choose suitable humidifying level as per environmental humidity
and maintains the humidity between 55% - 65%.
Mist Volume: Cool mist steam volume can be changed from level 1 to 3 by pressing this key.
Set Humidity: Humidity can be increased from 40% to 80% at every 5%.
(Machine automatically checks the humidity when it is turned ON)
Constant humidity: The machine controls the humidity automatically when set at a specific
percentage. For example, if you set the humidity at 50%, the machine will check environment
to see if it has reached 50%. The machine will keep working if it is less than 50% and will stop
working when it reaches 50% or above. Machine will start working again when the humidity
goes down by 4% (less than 46%) and has remained idle 3 minutes.
NOTE: When the device is turned on, it will keep working for 1 minutes even if the
environment humidity reaches the set humidity.
Warm Mist: Press this button to get warm mist from the humidifier. This button has 4 states
Max, Med, Low and Off. When the warm mist function is off, the machine only produces
cool mist.
NOTE: Sleeping Mode: Press and hold * * and * *at the same time for 2 seconds,
the machine will enter into Sleeping Mode and the display will turn OFF. You can turn the
display ON by pressing any one of the single buttons.

Using Aroma Function
Please follow the steps mentioned below:
a. Pull aroma box out of the box (picture1).
b. Use water-soluble aroma oil and drop on the sponge (picture 2).
c. Put the aroma box back into the machine, the aroma function will remain ON when
the humidifier is running. (picture 3).
d. To stop the aroma function or when storing the machine, please clean the sponge in
the aroma box.
CLEANING AND MAINTENACE
Remove the air flue as per below steps:
a. Remove the mist tube by un-screwing it counterclockwise (picture 1).
b. Hold the tail of the air flue and pull it up (picture 2).
c. Clear the water sink, take out the decaling pad and wash it with clear water. (picture 3)
d. Assemble the mist tube and air flue back after cleaning.
HF 710

Cleaning Transducer
1. Place 5-10 drops of vinegar on the surface of the transducer and wait for 2-5
minutes.
2. Using a small brush, cotton swab or tooth brush, gently clean the mineral film from
the surface of the transducer.
3. Rinse the transducer with clean water.
4. Never use sharp or solid objects for cleaning the transducer.
Cleaning Water Sink
1. Clean the water sink with a soft damp cloth. If there is excess film on the surfaces,
then soak the cloth with vinegar and repeat the process.
2. If there is a film in any of the depressions along the basin, drop a bit of vinegar into
depression and clean it out with a brush.
3. Rinse the sink with clean water.
Cleaning White Dust and Anti-Microbial Filter
Remove the filter from the water tank.
1. Put some white vinegar into a glass. Soak the filter in the vinegar for about 10
minutes.
2. Remove the filter from the glass and shake it several times.
3. Clean and rinse the filter once again with fresh water.
We recommend the following:
1. If you water is very hard, we recommend that you boil it first, allow it to cool
completely before use in the humidifier. The boiling will reduce the mineral
concentration in the water. The other option is to use distilled water if your mineral
level is still too high.
2. If you are using the machine on a daily basis, clean the transducer, water tank and
basin once a week.
3. When the water tank needs a refill, empty the remaining water from the tank and fill it
with fresh water.
4. Clean the whole machine and make sure to keep all the parts completely dry when
the machine is not in use.
HF 710
9

TROUBLESHOOTING
Trouble
Possible Reasons
Soluon
Power icon
is off or does not
work
Humidifier is not plugged into
the wall socket
Connect power cord to
electrical outlet and press
power buon.
Power light is on but no mist
No water in water tank.
Fill water tank with water.
The mist has a strange odour.
A new machine.
Remove the water tank,
unscrew the lid and let it air
out in a cool area for 12
hours.
It either has dirty water or the
water has been stagnant too
long.
Clean the water tank and refill
with clean water.
Power light is on, but the
machine doesn’t work.
Too much water in the water
basin.
Remove the water
tank. Take
a small cup and remove some
of the water from the
machine’s water basin.
Reinsert the water tank and
make sure that it sits
properly.
The volume of spray mist is
too low.
Too much mineral scale in the
water sink.
Clean transducer.
Water is too dirty or water
was kept too long in the tank.
Clean the water tank and refill
with clean water.
Abnormal noise
Vibraon in the water tank
because the water level is too
low.
Fill the water tank.
Machine is on an unstable
surface.
Move the unit to a
stable flat
surface.
Spray mist is coming out of
the area around the nozzle.
There are gaps between the
housing around jet nozzles
and
the top of the water tank.
Remove the jet nozzle from
the top of the water tank and
clean with a damp cloth.
Reaach to the water tank.
Water does not come down
to basin
Blocked up
filter
Rinse the filter by tap water
High Temperature Warning
No water in water sink caused
by broken water level sensor
Contact Heaven Fresh for
maintenance
High water level in the sink
caused by adding water the
wrong way
Flush the water of the water
sink and reset the water tank.
HF 710