The Heatit Push Button is a sleeping device. After adding it to
the network, it will not enter into sleep mode immediately, but
will maintain activation status for 30s while completing the
addition process. The LED indicator will stay on for this time, so
please be patient and wait for the LED indicator to turn off.
REMOVING FROM A ZWAVE NETWORK
There are two removing methods:
Method 1: Removing from the primary controller/gateway:
1. Set the primary controller/gateway to removing mode.
(Please refer to your primary controller manual on how to set
your controller to removing mode).
2. Press and hold down both buttons Iand O of Group 2 for 3
seconds, LED indicator turns on, the Push Button will be set to
removing mode, and stand by to be removed. After 7s the LED
indicator blinks 4 times quickly to indicate successful removal.
Method 2: A factory reset of the Push Button will force the Push
Button to be removed from a network. (Please refer to the part
“Factory Reset” of this manual).
Note: Factory reset is not recommended for removing devices.
Please use this procedure only if the primary controller/gateway
is missing or otherwise inoperable.
HOW TO CHECK IF THE PUSH BUTTON HAS ALREADY BEEN
ADDED TO A NETWORK
Press any button once. If the LED indicator does not turn on,
the Push Button does not belong to any network. If the LED
indicator turns on, it means that the Push Button has already
been added to a network. You must then run the removal
process (see ”Removing from a Z-Wave network” in this guide)
before adding the device to your network.
FACTORY RESET
Press and hold down both buttons I and O of Group 2 for a
minimum of 10 seconds until the LED indicator turns on and
then blinks 4 times quickly to indicate successful factory reset.
ASSOCIATION
Z-Wave devices control other Z-Wave devices. The relationship
betweenonedevicecontrolling anotherdevice iscalledassociation.
In order to control a subordinate device, the controlling device
needs to maintain a list of devices that will receive controlling
commands. These lists are called ”Association Groups” and are
activated when specific events are registered (e.g. sensor reports).
In the case of an association group being triggered, all devices
stored in the respective association group will receive
a common wireless command.
ASSOCIATION GROUPS
Each group supports maximum 5 nodes for association. A single
device may be associated with multiple groups in the gateway
simultaneously. In order to optimize your control experience,
the gateway will automatically remove devices that are not in
operational status in their association groups at the time.
ASSO-
CIATION
GROUPS
GROUP
NAME
MAX
NODES
DESCRIPTION
Group 1 Lifeline. 5 1. Send Command Class ”Device
Reset Locally Notification V1” to
associated devices of this group to
report factory reset information when
factory reset the Push Button.
2. When Push Button battery power
value changes, send Command Class
”Battery Report V1”to associated
devices of this group to report power
value information.
3. Push once or press and hold any
button to send scene activation
command to the associated devices
of this group using Command Class
“Central Scene Notification V3”
Group 2 Launch 1 5 Push I-/O-button of Group 2 once
to send ON/OFF command to
associated devices of this group using
Command Class ”Basic Set V2”.
Press and hold down I-/O-button of
Group 2 to send light intensity
increase/decrease command to
associated devices of this group using
Command Class ”Multilevel V4”.
Group 3 Launch 2 5 Push I-/O-button of Group 3 onceto
send ON/OFF command to asso-
ciated devices of this group using
Command Class ”Basic Set V2”.
Press and hold down I-/O-button
of Group 3 to send light intensity
increase/decrease command to
associated devices of this group using
Command Class ”Multilevel V4”.
SETTING AND REMOVING ASSOCIATIONS
(Note: All association information will be cleared automatically
once the device is excluded from the network.)
There are two methods to set associations:
1. Set association by operating primary controller/gateway to
send the association command to the Push Button:
When setting association from the primary controller/gateway,
the Push Button must be activated first. If it is not activated, you
should activate it manually.
The primary controller/gateway sends an association command
to the device using “Command Class ASSOCIATION” or
“Command Class Multi Channel Association”
2. Set association using the Push Button and the devices that
are to be controlled.
To control a Z-Wave device from the Push Button, the node ID of
this device needs to be assigned to one of the two association
groups. This is a three-step process:
a. Press and hold down both buttons Iand O of Group 2 for
3 seconds until the LED indicator turns on.
b. Push the I-button of any group once within 7s to associate
the device to this group. Push the O-button of any group once
within 7s to remove association of the device from this group.
c. Send Node Information Frame (please refer to the device
manual) from the subordinate device within 10 seconds, or set
the device to removing mode within 10 seconds, since this will
send Node Information Frame in removing mode.