Assembly Instructions M8102-EN
1. Proceed as follows in order to cool down the unit and empty
the mould (mould evacuation)
Display menu page Functions.
Select the function Cooling and activate with the key.
Select the function Mould evacuation and activate with the
key.
The activated function is indicated with the symbol.
2. Main switch off, remove the plug from the mains and empty
the unit.
3. Remove the cover from the unit (see Instruction Manual
Chapter Maintenance).
4. Loosen the screws in the front panel and hinge it down.
Fig. 1: Loosen Torx screws
5. Proceed as follows in order to remove the sound transducer
level measurement (BL 1):
Unplug cable on slot X53.4 at GIF-51 (A 4) , open velcro cable
fastener, remove plastic cable fastener and completely remove
the cable.
Loosen the Torx screws (1) of the mounting plate for the sound
transducer (Fig. 1).
Remove sound transducer.
Remove O-ring.
6. Proceed as follows in order to assemble the sound transducer
level measurement:
Insert the new O-ring in the groove.
Refit the sound transducer with the mounting plate and screws
carefully.
Transfer the cable labelling of the old sound transducer to the
new sound transducer.
Plug in the cable of the sound transducer on slot X53.4.
ATTENTION!
Damage due to wrong mounting
An incorrect assembly can lead to malfunctions.
Therefore:
–Observe correct mounting.
–Handle all parts with care.
7. Close and secure the front panel.
8. Press the key to switch on the unit and check it for leaks.