3Parameters
3.1 General an hy raulic
Description Pressure switch
Design Spring-loaded piston-type pressure switch
Mo el Pipe connection, manifold mounting
Material DG 1: Galvanised steel housing
DG 3: Zinc die casting housing
Tightening torques See Chapter 4, "Dimensions"
Installation position DG 1 R.. = Vertical, sideways scale, hydraulic part at the bottom
DG 3.. = As desired
Hy raulic ui Hydraulic oil: according to part 1 to 3;
ISO VG 10 to 68 according to DIN ISO 3448
Viscosity limits: min. approx. 4, max. approx. 1500 mm2/s
opt. operation approx. 10... 500 mm2/s.
Also suitable for biologically degradable hydraulic uids type HEPG (polyalkylene glycol)
and HEES (synthetic ester) at operating temperatures up to approx. + 0°C.
Cleanliness level ISO 4406
21/18/15...19/1 /13
Temperatures Ambient: approx. -40 ... +80°C, Fluid: -25 ... +80°C, Note the viscosity range!
Start temperature: down to -40°C is permissible (observe start viscosities!),
as long as the steady-state temperature is at least 20K higher during subsequent operation.
Biologically degradable pressure uids: Observe manufacturer's specifications. By considera-
tion of the compatibility with seal material not over + 0°C.
Hy raulic ata of DG 35 -X.-KB an
DG 364 -X.-KB Temperature range -30°C < x < 0°C 0°C < x < 50°C
Speed of pressure change < 6 bar/s
DG 35 80 ... 250 bar 20 ... 250 barPressure setting pmin to pmax
DG 364 35 ... 50 bar 12 ... 50 bar
DG 35Maximum pressure pmax
DG 364 500 bar 500 bar