GRG Banking CA-10 Manual de usuario

CA-10
Fast Deposit Module
User Manual
No.:
Version: V1.0
Issued on: September 2017

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party I / II
Document History
No. and name
Version
Date
Revision
description
Personnel involved
Fast Deposit Module
CA-10 User Manual
V1.0
2017.09
Created
Prepared: Dai Xiaowei,
Huang Changyan
Approved by: Wang
Yunlong, Zhang Enfu
Fast Deposit Module
CA-10 User Manual
V1.1
2018.03
Match with
new Toolplus
Prepared:Liu Peng
Approved: Zhang Enfu

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party II / II
Document History................................................................................................................... I
Chapter 1 Overview..................................................................................................................1
1. Composition..............................................................................................................1
2. Technical parameters ................................................................................................2
3. Note processing procedure........................................................................................2
3.1 Loading procedure ............................................................................................2
3.2 Pre-deposit process............................................................................................3
3.3 Deposit process .................................................................................................3
Chapter 2 Overall Dimensions and Wiring...............................................................................5
1. Overall dimensions....................................................................................................5
2. Wiring .......................................................................................................................5
Chapter 3 Installation................................................................................................................6
1. Installation dimensions..............................................................................................6
2. Maintenance space requirements ..............................................................................6
Chapter 4 Method to Debug and Maintain CA10 with Toolplus..............................................8
1. Install Toolplus .........................................................................................................8
2. Connecting CA10 to PC............................................................................................8
3. Run the Toolplus.....................................................................................................12
4. Upgrade main control board....................................................................................13
5. Upgrade DSP...........................................................................................................16
6. Upgrade FPGA........................................................................................................18
7. View version ...........................................................................................................20
8. Set currency type.....................................................................................................20
9. Set work model .......................................................................................................21
10. Deposit process ...............................................................................................22
11. Get the note information .................................................................................26
12. Compensation image collection......................................................................27
13. Reject image collection...................................................................................28
14. Thickness calibration ......................................................................................28
15. Black and white adjustment ............................................................................29
16. Error code query..............................................................................................30
Chapter 5 CA10 Thickness Adjustment Instructions........................................................31
Chapter 6 CA10 Note Feeding Clearance Adjustment Instructions................................35
Chapter 7 Overall Development Support...........................................................................37

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party 1 / 35
Chapter 1 Overview
1. Composition
As shown in Figure 1-1, the CA-10 module is divided into 10 parts depending on their
functions:
1) Input slot;
2) Note validator;
3) Thickness assembly;
4) Lower transport;
5) Diverter;
6) Reject slot;
7) Escrow slot;
8) External shutter;
9) Output slot;
10) Internal shutter
11) Pressure plate;
12) Connection port;
1
2
3
12
6
7
8
9
5
41011
Figure 1-1

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party 2 / 35
2. Technical parameters
Supported
currency
Support the fourth and fifth sets of all
RMB above 1 yuan (upgrade to
support multinational currencies).
Capacity of
note slots
500 notes for the input slot
(optionally 1,000 notes), 200 notes
for the escrow slot, 100 notes for the
output slot
Loading
speed
720 notes per minute
Operating
environment
0℃~40 ℃20% ~90% RH
(non-condensing)
Continuo
us
replenish
ment
Supported
Dimensions of
supported
envelope
Max. length 178 mm ×width 90 mm
×thickness 15 mm
Slot
quantity
1 input slot, 1 output slot and 1 escrow
slot
Overall
dimensions
Length 423 mm ×Width 3,40 mm ×
Height 394 mm
Power
supply
environm
ent
100-240 VAC, 50/60Hz
Weight
Net weight: 19 kg
Communi
cation
interface
LAN
3. Note processing procedure
3.1 Loading procedure
As shown by the red path in Figure 1-2, the notes fed into the note validator through feeder roller
from the input slot pass through the thickness assembly and arrive at lower transport. The notes
validated as acceptable enter into the escrow slot through the diverter as shown by the red path;
and the notes validated as unacceptable enter into the reject slot through the diverter as shown by
the blue path.

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party 3 / 35
Figure 1-2
3.2 Pre-deposit process
As shown in Figure 1-3, when the notes fed forward the escrow slot reach the specified quantity,
the machine stops note loading and the sensor performs the first detection. If notes are stacked
normally in the escrow slot, the internal shutter moves to the right and the pressure plate presses
the notes forward; if notes have exceptions like bursting notes or are not stacked normally in the
escrow slot, the external shutter opens automatically, and then it is required to take out the notes
from the escrow slot manually and deposit again.
Figure 1-3
3.3 Deposit process
As shown in Figure 1-4, the pressure plate presses forward the notes and the sensor performs the
second detection. If notes are stacked normally in the escrow slot, the delivery roller rotates
anticlockwise, and the notes are delivered to the output slot with the force of the delivery roller; if
notes has exception like bursting notes or are not stacked normally in the escrow slot, the internal
shutter moves to the left, and the pressure plate returns back and the external shutter opens. Then
it is required to take out the notes from the escrow slot manually and deposit again.

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party 4 / 35
Figure 1-4

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party 5 / 35
Chapter 2 Overall Dimensions and Wiring
1. Overall dimensions
The overall dimensions are shown in Figure 2.1:
Figure 2-1
2. Wiring
As shown in Figure 2-2, the external interfaces of CA-10 module are divided into power interface
and communication interface, in which the power supply is 100-240VAC and the communication
is realized by RJ45 cable which is used to control data interaction and transmission.
Figure 2-2
Power interface
Power switch
RJ45 cable interface

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party 6 / 35
Chapter 3 Installation
1. Installation dimensions
Refer to Figure 3-1 for the dimensions of mounting holes, and fix the bottom of the CA10.
Figure 3-1
2. Maintenance space requirements
To facilitate the overall cleaning and maintenance, it is necessary to reserve enough space in
Output slot size

Fast Deposit Module CA10 User Manual
Confidential material of GRG, No disclosure to unauthorized Party 7 / 35
advance. As shown in Figure 3-2, turn up the upper transport of CA10 to clean the space required
for maintenance.
Figure 3-2
Tabla de contenidos
Otros manuales de Unidad de control de GRG Banking
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario