GRAS 12AB Manual de usuario

Instruction Manual
12AB 2-Channel Power Module for
GRAS Intensity Probes
LI0113 – 12 February 2008

CONTENTS
1. Introduction and Description ......................................3
1.1 Polarization Voltage ................................................3
1.2 PreamplierVoltageSupplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 PowerSupplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.4 Input/Output ......................................................4
2. External Features ................................................5
2.1 Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Rear Panel .......................................................7
3. Internal Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.1 Battery Pack ......................................................8
3.2 User-servicableSwitches ............................................8
4. Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 BatteriesandExternalPower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2 PolarizationVoltageandPreamplierVoltage ............................9
5. Service and Repair ..............................................10
6. Specications ..................................................11

Intensity Power Module Type 12AB - Page 3
Fig. 1.1 Intensity Power Module Type 12AB
* FactorysettingsforusewithGRASSoundIntensityProbetype50AIversionB
1. Introduction and Description
TheG.R.A.S.IntensityPowerModuleType12AB(Fig.1.1)isatwo-channelpowersupplyfor
usewithversionsB,CandDoftheG.R.A.S.SoundIntensityProbeType50AI.
TheType12ABisbuiltintoasturdyanodizedaluminiumcabinetandcanbepoweredeitherby
internalstandardbatteriesoranexternalDCsupply(12V-18V),e.g.amains/lineadapter.
AblockdiagramofitsmaincomponentsisshowninFig.1.2.
1.1 Polarization Voltage
Thepolarizationvoltagecanbesettoeither0Vor200Vviaaninternalswitch(seesection3.2).
Theseare:
• 200V*—forusewithType50AI,or
• 0V—forprepolarizedmicrophones
1.2 PreamplierVoltageSupplies
Thepreampliervoltagesupplycanbesettoeither28VDCor120VDCviaaninternalswitch
(seesection3.2).Theseare:
• 120V*—formaximumdynamicrange,or
• 28V—forminimumpowerconsumption
1.3 Power Supplies
TheType12ABcanrunoninternalbatterieswithabatterylifeofapproximately10hoursusing
G.R.A.S.preampliers,orfromanexternalpowersupplyof12-18VDC,e.g.aG.R.A.S.
mains/lineadapterAB0002(Europe)/AB0003(USA).

Intensity Power Module Type 12AB - Page 4
Fig. 1.2 Block diagram of the Type 12AB
1.4 Input/Output
Theinputisa12-pinLEMOsocketonthefrontpanelwhichiswiredup(seeFig.2.3)forthe
G.R.A.S.SoundIntensityProbeType50AIversionsB,CandD.Thisinputisalsoconnectedto
the9-pinD-subconnectorinorderto:
a) Transmitthestate(pressed/notpressed)ofthetwopush-buttonsonthehandleoftheType
50AI
Whenpressed:
thebluebuttontransmitsDSR
thegreybuttontransmitsCTS
b) SignaltheresponsesviathetwoLEDsalsoonthehandleoftheType50AI
Whenlit:
theredLEDissignallingRTS
thewhiteLEDissignallingDTR
Bysuitablyprogrammingthecomputer’ssoftware,measurementsanddataacquisitioncanbe
controlledinteractivelyviathesepush-buttonsandLEDs.
ViatwostandardBNCconnectors(AandB)onthefrontpannel,theprobe’stwooutputsignals
areavailable,DC-decoupledforusewithanalyzers,voltmeters,oscilloscopesetc.
Signal input A
Signal output A
Signal input B
Polarization
voltage
200V
Preamplifier
supply
120V
Preamplifier
supply
28V
0 V
Signal output B
RS 232 lines
AC AC

Intensity Power Module Type 12AB - Page 5
2. External Features
2.1 Front Panel
Thefrontpanelhasthefollowingfeatures(seeFig.2.1)
• Powerswitchandbattery-levelmeter.
Ifthepowersupplyiscorrect,thebattery-levelmeterwillpointtothegreenzone.Ifitpoints
totheredzone,eitherthebatteriesarelowandshouldbechanged(seesection3.1)orthe
externalDCsupplyvoltageistoolow.
• Intensity-probe’sOutputChannels(AOUT B).
BNCsocketsfortheintensityprobe’soutputsignals,takendirectlyfromthePROBE IN
connectorandsucceedinglyDC-decoupled.SeealsoblockdiagraminFig.1.2.
• RS232socket(RS - 232).
9-pinD-subconnectorforfacilitatinginteractiveremotecontrolofintensitymeasurements.
WiringdiagramshowninFig.2.2
• Probeinputsocket(PROBE IN).
12-pinLEMOinputconnectorforthetwomicrophonepreampliersoftheintensityprobe
aswellastheRS232linesforitspushbuttonsandLEDs.Wiringdiagramshownin
Fig. 2.3.
Fig. 2.1 Front panel of the Intensity Power Module Type 12AB
Battery-levelmeter
OputCh.B
Probeinput
12-pinLEMOsocket
Power,On/Offtoggleswitch
OutputCh.A
RS232
9-pinD-subconnector

Intensity Power Module Type 12AB - Page 6
Note:RS - 232andPROBE INareinterconnectedasfollows:
Line RS - 232 PROBE IN
DataTerminalReady Pin4 Pin12
DataSetReady Pin6 Pin9
RequestToSend Pin7 Pin11
ClearToSend Pin8 Pin10
Fig. 2.3 12-pin LEMO female socket 1B (external
view). The four inner pins are connected to
the socket shown in Fig. 2.2
Fig. 2.2 9-pin female D-sub connector socket for con-
necting directly to an RS232 computer port
(external view)

Intensity Power Module Type 12AB - Page 7
Fig. 2.4 Rear panel of the Intensity Power Module Type 12AB
2.2 Rear Panel
Therearpanelhasthefollowingfeatures(seeFig.2.4)
• Twist/releaseholderfor315mA(Slow).
• Inputsocketforanexternalpowersupplyof12 - 18 V DC;centrepin+terminal.Theuseof
anexternalpowersupplyautomaticallydisablespowerfromthebatteries.
• Lockingscrew
Unscrewtoremovebaseplateandgainaccesstointernalsettingswitches.
Fuse315mA(Slow)
Inputforexternalpowersupply
12-18VDC
Lockingscrewfor
baseplate

Intensity Power Module Type 12AB - Page 8
3. Internal Features
Note:switchtheType12ABoffanddisconnectitfromanyexternalpowersupplybeforeremov-
ingthebaseplateforanyreason.Afterwardsreplacethebaseplate.
Thebatterypackanduser-servicableswitchesarecontainedwithinthecabinetoftheType
12AB.Togainaccesstothese,rstremovetheknurledlockingscrew(seeFig.2.4)andslide
thebaseplateoff.
Fig. 3.1 Showing the battery pack of the
Intensity Power Module Type
12AB
3.1 Battery Pack
Takeoutthebatterytray(Fig.3.1)andreplaceallthebatteries(10xLR6(AA)standardalkaline
cells),makingsurethatthepolarityisasindicatedonthebatterytray.
3.2 User-servicable Switches
The(internal)user-servicableslideswitchesareshowninFig.3.2.
• Preampliersupplyselectpairofswitches:
- Polarization voltage2-positionswitch(applicabletobothchannels)selects:
0 V forprepolarized(electret)microphones
or 200 V forexternally-polarizedmicrophones
- Supply voltage2-positionswitch(applicabletobothchannels)selects:
120 V formaximumdynamicrange
or 28 V forminimumpowerconsumption
Fig. 3.2 Showing the internal switches of the
Intensity Power Module Type 12AB
Polarizationvoltage
• 0 V
• 200 V
Supplyvoltage
• 120 V
• 28 V
Note:
SwitchofftheIntensityPower
Modulebeforechangingany
preamplierpowersettings

Intensity Power Module Type 12AB - Page 9
4. Operation
4.1 Batteries and External Power
TheType12ABcanbepoweredeitherbyinternalbatteries(Fig.3.1)orfromanexternalpower
supplyviatheDCinputontherearpanel(Fig.2.4).Ifanexternalpowersupplyisused,thebat-
terieswithintheunitwillbeautomaticallydisconnected.Externalpowershouldbe12-18VDC,
e.g.fromaG.R.A.S.mains/lineadapterAB0002(Europe)/AB0003(USA).
WhenevertheType12ABisswitchedon,thebattery-levelmeteronthefrontpanel(Fig.2.1)
shouldalwayspointtothegreenzonetoensurecorrectoperation.Ifitpointstotheredzone,
eitherthebatteriesarelowandshouldbechanged(seesection3.1)ortheexternalDCsupply
voltageistoolow.
4.2 PolarizationVoltageandPreamplierSupplyVoltage
Polarizationvoltagecanbeswitchedfrom200Vto0V(seesection3.2).Use200Vforstandard
externally-polarizedcondensermicrophones,and0Vforprepolarized(electret)microphones.
Preampliersupplyvoltagecanbeswitchedfrom28Vor120V.Use28Vforminimisingpower
consumption,itisalsosufcientformostapplicationsbutlimitsthedynamicrangeofthemicro-
phonepreampliersusedwiththeType12AB.Use120Vtoutilisethefulldynamicrangeofthe
microphonepreamplier.InthiscasethedynamicrangewillbedeterminedbytheType12AB.

Intensity Power Module Type 12AB - Page 10
5. Service and Repair
Repairsshouldbecarriedoutonlybyqualiedpersonal.TheIntensityPowerModuleType
12ABshouldnotbedismantledwithpoweronbecauseofhigh-voltagecircuits.
Tabla de contenidos
Otros manuales de Unidad de control de GRAS
Manuales populares de Unidad de control de otras marcas

Festo
Festo Compact Performance CP-FB6-E Manual de lista de piezas

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Manual de usuario

JS Automation
JS Automation MPC3034A Manual de usuario

JAUDT
JAUDT SW GII 6406 Series Guía rápida

Spektrum
Spektrum Air Module System Manual de usuario

BOC Edwards
BOC Edwards Q Series Manual de usuario