Electrical Requirements
The following power supply must be provided:
2620DX, 2620DTX and 2621DX, 2621DTX: 230/400 V~, 6076 W, 50 Hz
This unit is designed to operate on single phase, 16 A P, 4 wire supply, 230 V~ (2 Hot,
1 Neutral, 1 Ground). All electrical components in this machine are 230 V (motors, heat
elements, lights, etc.) and therefore require “Hot to Neutral” connection (NOT “Hot to Hot”).
Machine must be properly grounded to prevent electrical shock to personnel.
Failure to do so could result in serious injury, or death.
DO NOT immerse any part of this equipment in water.
DO NOT use excessive water when cleaning.
Keep cord and plug off the ground and away from moisture.
Always unplug the equipment before cleaning or servicing.
Make sure all machine switches are in the OFF position before plugging the
equipment into the receptacle.
008_051514
A certified electrician must furnish sufficient power for proper machine operation and install any
supplied receptacle. We recommend this equipment be on a dedicated and protected circuit.
Failure to wire properly will void the warranty and may result in damage to the machine. It is Gold
edal Products Co.’s recommendation that this machine be plugged directly into a wall outlet. The
use of extension cords is not recommended due to safety concerns, and may cause sacrificed
and/or reduced performance. ake sure cord is located to prevent a trip hazard or unit upset.
Receptacle Wiring Diagram
A certified electrician must supply and install the required wall receptacle for this unit, follow
the I PORTANT instructions shown below.
This unit is designed to operate on single phase, 16 A P, 4 wire supply. All electrical components
in this machine are 230 V. If the receptacle is wired incorrectly, the heat elements/kettle and
other electrical components could be at 400 V potential instead of the needed 230 V, resulting in
excessive temperatures in the heat elements (i.e.: kettle) and possible fire, and/or damage to
electrical components.
(Neutral) Wire
L3
N
(
connect Grey here.)
E-G
L2
L1
(Hot) Wire
(Hot) Wire
Green/Yellow
(Ground) Wire